IFM AC6000 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor IFM AC6000 (94 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 17 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/94
>
>
80293944 / 00 04 / 2020
Operating Instructions
IO-Link Master with AS-
Interface Interface
StandardLine
4 Ports
IP 65 / IP 66 / IP 67
AC6000
Firmware: 2.4.x or higher
English
IO-Link Master with AS Interface Interface StandardLine 4 Po- rts IP 65 / IP 66 / IP 67
2
Contens
1 4 Preliminary note
1.1 Legal and copyright information ........................................................................................... 4
1.2 Symbols used ....................................................................................................................... 5
1.3 Warnings used ..................................................................................................................... 5
1.4 User documentation for this device...................................................................................... 6
1.5 Modification history .............................................................................................................. 6
2 Safety instructions 7
2.1 General 7................................................................................................................................
3 8 Functions and features
4 9 Function
4.1 Link IO- .................................................................................................................................. 9
4.1.1 IO -Link supply .............................................................................................................................. 9
4.2 interface AS- ......................................................................................................................... 9
4.3 Parameter setting ................................................................................................................. 9
4.4 Visual indication .................................................................................................................10
5 Mounting 11
5.1 Mounting the device ...........................................................................................................11
6 Electrical connection 12
6.1 Notes ..................................................................................................................................12
6.2 IO-Link ports .......................................................................................................................13
6.2.1 Connecting IO Link devices for Class A operation- ..................................................................... 13
6.2.2 Connecting IO Link devices for Class B operation- ..................................................................... 14
6.3 Connecting the unit ............................................................................................................15
7 Operating and display elements 16
7.1 Overview ............................................................................................................................16
7.2 LED indicators ....................................................................................................................17
7.2.1 Status LEDs ............................................................................................................................... 17
7.2.2 Voltage supply ............................................................................................................................ 17
7.2.3 IO -Link ports (Class A) ............................................................................................................... 18
8 - Set up 19
9 Configuration 20
9.1 Notes ..................................................................................................................................21
9.1.1 Device structure ......................................................................................................................... 21
9.1.2 Options for parameter setting ..................................................................................................... 21
9.1.3 Using the command interface ..................................................................................................... 22
9.2 Addressing the AS i slave of the AC6000- ..........................................................................24
9.2.1 Addressing via AS- i master ........................................................................................................ 24
9.2.2 Addressing with addressing unit ................................................................................................. 25
IO-Link Master with AS Interface Interface StandardLine 4 Ports IP 65 / IP 66 / IP 67-
3
9.3 Adjusting the gateway profile .............................................................................................26
9.3.1 Example: Setting the gateway profile ......................................................................................... 27
9.4 Configuring IO-Link ports ...................................................................................................28
9.4.1 Note: Device validation and data storage ................................................................................... 28
9.5 Reading / writing parameters of the IO Link devices- .........................................................29
9.5.1 Example: Reading parameter ..................................................................................................... 29
9.5.2 Example: Writing parameter ....................................................................................................... 31
9.6 Reading / writing process data ...........................................................................................33
9.7 Reading identification and diagnostic information .............................................................33
9.8 33 Reading IO Link events- .....................................................................................................
9.9 Resetting IO-Link master ...................................................................................................33
9.10 Updating the firmware ........................................................................................................34
10 Maintenance, repair and disposal 35
10.1 Cleaning process ...............................................................................................................35
10.2 Replacing IO Link device- ...................................................................................................35
11 36 Factory settings
12 Accessories 37
13 38 Appendix
13.1 Technical data ....................................................................................................................39
13.1.1 Application .................................................................................................................................. 39
13.1.2 Electrical data ............................................................................................................................. 39
13.1.3 Inputs / outputs ........................................................................................................................... 39
13.1.4 Inputs .......................................................................................................................................... 40
13.1.5 Outputs ....................................................................................................................................... 40
13.1.6 Interfaces .................................................................................................................................... 40
13.1.7 Operating conditions .................................................................................................................. 41
13.1.8 Approvals / Tests ........................................................................................................................ 41
13.1.9 AS-i classification ....................................................................................................................... 41
13.1.10 Mechanical data ......................................................................................................................... 41
13.1.11 Electrical connection .................................................................................................................. 42
13.2 Interface AS- .......................................................................................................................43
13.2.1 Mapping: inputs and outputs of the IO Link ports- ....................................................................... 44
13.3 Command interface ............................................................................................................61
13.3.1 Structure of the command interface ...........................................................................................61
13.3.2 Overview: Acyclic commands ..................................................................................................... 64
13.3.3 0x01: Read IO Link Port Configuration Errors- ............................................................................ 65
13.3.4 0x02: Write IO-Link Port Configuration ....................................................................................... 66
13.3.5 0x03: Read IO Link Port Configuration- ....................................................................................... 70
13.3.6 0x04: Read Input Process Data .................................................................................................. 73
13.3.7 0x05: Read Output Process Data ............................................................................................... 75
13.3.8 0x06: Write Output Process Data ............................................................................................... 77
13.3.9 0x07: Read Diagnosis Data ........................................................................................................ 79
13.3.10 0x08: Factory Defaults................................................................................................................ 81
13.3.11 0x09: Set IO Link Failsafe Data- .................................................................................................. 82
13.3.12 0x0A: Write Parameter ............................................................................................................... 84
13.3.13 0x0B: Read Parameter ............................................................................................................... 87
13.3.14 0x0C: Read Device Name, Serial Number, HW and SW Revisions ........................................... 89
13.3.15 0x0D: Update Firmware.............................................................................................................. 91
14 93 Index


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: AC6000

Heb je hulp nodig?

Als je hulp nodig hebt met IFM AC6000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM DP4302 Handleiding

12 April 2024
IFM

IFM EVCB02 Handleiding

11 Maart 2024
IFM

IFM EVCB03 Handleiding

11 Maart 2024
IFM

IFM EVF666 Handleiding

11 Maart 2024
IFM

IFM TM4599 Handleiding

8 Januari 2024
IFM

IFM ZB0074 Handleiding

8 Januari 2024
IFM

IFM EVF661 Handleiding

8 Januari 2024
IFM

IFM IIP201 Handleiding

7 Januari 2024
IFM

IFM DP4200 Handleiding

7 Januari 2024
IFM

IFM IIP200 Handleiding

7 Januari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd