HP ProLiant SL390s G7 Handleiding

HP Server ProLiant SL390s G7

Lees hieronder de đź“– handleiding in het Nederlandse voor HP ProLiant SL390s G7 (86 pagina's) in de categorie Server. Deze handleiding was nuttig voor 24 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/86
HP ProLiant SL390s G7 1U half width Server
User Guide
Part Number 625535-001
August 2010 (First Edition)
© Copyright 2010 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the
express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft, Windows, and Windows Server are U.S. registered trademarks of Microsoft Corporation. Intel, Pentium, and Itanium are trademarks
or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. UNIX is a registered trademark of The
Open Group.
Intended audience
This document is for the person who installs, administers, and troubleshoots servers and storage systems.
HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards
in products with hazardous energy levels.
Contents
Component identification ............................................................................................................... 6
Front panel components ................................................................................................................................ 6
Front panel LEDs and buttons ......................................................................................................................... 7
Rear panel components 8 ................................................................................................................................
Rear panel LEDs and buttons ......................................................................................................................... 9
System board ............................................................................................................................................10
System board components ................................................................................................................ 10
System board switches ...................................................................................................................... 11
NMI functionality ............................................................................................................................. 12
DIMM slots ...................................................................................................................................... 13
Hard drive numbering ................................................................................................................................ 13
Battery pack LEDs ....................................................................................................................................... 14
System fans ............................................................................................................................................... 15
Removing the server from the chassis ............................................................................................................ 15
Setup ......................................................................................................................................... 17
Optional installation services ....................................................................................................................... 17
Rack planning resources ............................................................................................................................. 17
Optimum environment................................................................................................................................. 18
Space and airflow requirements ........................................................................................................18
Temperature requirements ................................................................................................................. 19
Power requirements .......................................................................................................................... 19
Electrical grounding requirements ...................................................................................................... 19
Rack warnings ........................................................................................................................................... 20
Identifying the contents of the server shipping carton ...................................................................................... 20
Installing hardware options ......................................................................................................................... 20
Installing the server into the chassis .............................................................................................................. 21
Installing the operating system ..................................................................................................................... 22
Powering up and configuring the server ........................................................................................................ 23
Power down the server ...............................................................................................................................23
Registering the server.................................................................................................................................. 24
Hardware options installation ....................................................................................................... 25
Introduction ............................................................................................................................................... 25
Processor options ....................................................................................................................................... 25
Memory configurations ............................................................................................................................... 28
Installing DIMMs .............................................................................................................................. 29
Hard drive guidelines ................................................................................................................................. 30
Installing a hard drive ....................................................................................................................... 30
Removing a hard drive ..................................................................................................................... 31
Expansion board options ............................................................................................................................ 32
Installing a low-profile expansion board ............................................................................................. 32
Cabling ..................................................................................................................................... 34
SAS or SATA power cabling options ............................................................................................................ 34
Battery cabling for BBWC ........................................................................................................................... 34
Configuration and utilities ............................................................................................................ 35


Product specificaties

Merk: HP
Categorie: Server
Model: ProLiant SL390s G7
Kleur van het product: Black,Grey
AC invoer voltage: 90 - 264 V
AC invoer frequentie: 47 - 63 Hz
Temperatuur, in bedrijf: 10 - 35 °C
Processorfamilie: Intel
Aantal USB 2.0-poorten: 3
VGA (D-Sub)poort(en): 1
Aantal Ethernet LAN (RJ-45)-poorten: 2
Netvoeding: - W
Relatieve luchtvochtigheid, in bedrijf: 10 - 90 procent
Ethernet LAN, data-overdrachtsnelheden: 10,100,1000 Mbit/s
Temperatuur bij opslag: -30 - 60 °C
Processor socket: Socket B (LGA 1366)
PCI Express slots versie: 2.0
Soort optische drive: Nee
Compatibele besturingssystemen: Windows Server\nRed Hat Enterprise Linux\nSUSE Linux Enterprise Server\nVMware ESX
Luchtvochtigheid bij opslag: 5 - 95 procent
Type behuizing: Rack (4U)
ECC: Ja
Ethernet interface type: Fast Ethernet,Gigabit Ethernet
Chipset moederbord: Intel® 5520
PCI Express x16 slots: 8
Grafische adapter-familie: AMD
Koperen ethernetbekabelingstechnologie: 1000BASE-T,1000BASE-TX,100BASE-TX,10BASE-T
Ondersteunde opslagstationinterfaces: Serial Attached SCSI (SAS),Serial ATA
Seriële poort(en): 1
PCI Express x8 slots: 1
Soorten RAID: 0,1,10
Maximum geheugen grafische adapter: 64 MB
Compatibele processors: Intel® Xeon®
Ondersteunde processor frequentie ( max): 3.6 GHz
Aantal ondersteunde processoren: 2
Intel® Xeon series: E5500,E5600,L5600,X5600
Maximum UDIMM geheugen: 192 GB
Aantal DIMM sloten: 12
Ondersteunende RDIMM klok snelheden: 800,1066,1333 MHz
Ondersteunend DIMM module capaciteiten: 16GB,4GB
Aantal storage drives ondersteund: 8
Opslagcontroller: HP Smart Array B110i
Opslagschijf afmetingen ondersteund: 2.5 "
AC-ingangsspanning: 90 - 264 V
AC-ingangsfrequentie: 47 - 63 Hz
Bedrijfstemperatuur (T-T): 10 - 35 °C
Relatieve vochtigheid in bedrijf (V-V): 10 - 90 procent

Heb je hulp nodig?

Als je hulp nodig hebt met HP ProLiant SL390s G7 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Server HP

Handleiding Server

Nieuwste handleidingen voor Server