HP ProLiant ML110 Gen9 Handleiding
Bekijk gratis de handleiding van HP ProLiant ML110 Gen9 (138 pagina’s), behorend tot de categorie Server. Deze gids werd als nuttig beoordeeld door 113 mensen en kreeg gemiddeld 4.5 sterren uit 57 reviews. Heb je een vraag over HP ProLiant ML110 Gen9 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/138

HP ProLiant ML110 Gen9 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 781889- 001
March 2015
Edition: 1

© Copyright 2015 Hewlett- Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Linux® is the registered trademark of Linus Torvalds in the U.S. and other countries.
Microsoft® and Windows® are U.S. registered trademarks of the Microsoft group of companies.
MicroSD is a trademark or a registered trademark of SD- n the United States, other countries or both. 3C i
Red Hat® is a registered trademark of Red Hat, Inc. in the United States and other countries.
VMware® is a registered trademark of trademark of VMware, Inc. in the United States and/or other jurisdictions.

Contents 3
Contents
Component identification ............................................................................................................... 7
Front panel components ............................................................................................................................. 7
Front panel LEDs and buttons ...................................................................................................................... 8
Front panel LED power fault codes ..................................................................................................... 8
Rear panel components .............................................................................................................................. 9
Rear panel LEDs...................................................................................................................................... 10
System board components ........................................................................................................................ 11
System maintenance switch ............................................................................................................. 12
NMI functionality ........................................................................................................................... 13
DIMM slot locations ....................................................................................................................... 13
F an locations .......................................................................................................................................... 14
Drive numbering ..................................................................................................................................... 14
HP SmartDrive LED definitions ................................................................................................................... 16
Operations ................................................................................................................................. 18
Power up the server ................................................................................................................................. 18
Power down the server ............................................................................................................................. 18
Remove the access panel.......................................................................................................................... 18
Install the access panel............................................................................................................................. 19
Remove the front bezel ............................................................................................................................. 20
Install the front bezel ................................................................................................................................ 21
Remove the PCI air baffle ......................................................................................................................... 22
Install the PCI air baffle ............................................................................................................................ 22
Remove the system air baffle ..................................................................................................................... 23
Install the system air baffle ........................................................................................................................ 24
Setup ......................................................................................................................................... 25
Optional installation services .................................................................................................................... 25
Optimum environment .............................................................................................................................. 25
Space and airflow requirements ...................................................................................................... 25
Temperature requirements ............................................................................................................... 26
Power requirements ....................................................................................................................... 27
Electrical grounding requirements .................................................................................................... 27
Server warnings and cautions ................................................................................................................... 27
Identifying tower server shipping carton contents ......................................................................................... 28
Installing hardware options ....................................................................................................................... 29
Setting up a tower server .......................................................................................................................... 29
Installing the server into a rack .................................................................................................................. 29
Rack warnings ........................................................................................................................................ 30
Installing the operating system................................................................................................................... 31
P owering on and selecting boot options in UEFI Boot Mode.......................................................................... 31
Registering the server ............................................................................................................................... 32
Hardware options installation ....................................................................................................... 33
Introduction ............................................................................................................................................ 33
Drive cage options .................................................................................................................................. 33
4- - bay LFF hot plug drive cage option................................................................................................ 33
Product specificaties
Merk: | HP |
Categorie: | Server |
Model: | ProLiant ML110 Gen9 |
Breedte: | 195 mm |
Diepte: | 480.5 mm |
Hoogte: | 440 mm |
Bluetooth: | Nee |
Frequentie van processor: | 1.6 GHz |
Processorfamilie: | Intel® Xeon® E5 v3 |
Processormodel: | E5-2603V3 |
Aantal processorkernen: | 6 |
Vormfactor: | 4.5U |
Ethernet LAN: | Ja |
Geïntegreerde geheugenkaartlezer: | Ja |
Compatibele geheugenkaarten: | MicroSD (TransFlash) |
Processor lithografie: | 22 nm |
Aantal USB 2.0-poorten: | 3 |
VGA (D-Sub)poort(en): | 1 |
Aantal Ethernet LAN (RJ-45)-poorten: | 2 |
Netvoeding: | 350 W |
Intern geheugen: | 8 GB |
Intern geheugentype: | DDR4-SDRAM |
Bekabelingstechnologie: | 10/100/1000Base-T(X) |
Temperatuur bij opslag: | -30 - 65 °C |
Intel® Wireless Display (Intel® WiDi): | Nee |
Aantal poorten USB 3.2 Gen 1 (3.1 Gen 1) Type A: | 5 |
Processor socket: | LGA 2011-v3 |
Stepping: | R2 |
Systeembus: | 6.4 GT/s |
Processor aantal threads: | 6 |
PCI Express slots versie: | 3.0 |
Processor operating modes: | 64-bit |
Processor cache: | 15 MB |
Bus type: | QPI |
PCI Express configuraties: | x4, x8, x16 |
Thermal Design Power (TDP): | 85 W |
Codenaam processor: | Haswell |
Maximaal aantal PCI Express-lijnen: | 40 |
Processor cache type: | Smart Cache |
ECC ondersteund door processor: | Ja |
Processorfabrikant: | Intel |
Maximum intern geheugen: | 256 GB |
Totale opslagcapaciteit: | 0 GB |
Soort optische drive: | Nee |
Ondersteunde instructie sets: | AVX 2.0 |
Intel® My WiFi Technology (Intel® MWT): | Nee |
Intel® Hyper Threading Technology (Intel® HT Technology): | Nee |
Intel® Turbo Boost Technology: | Nee |
Intel® Quick Sync Video Technology: | Nee |
Intel® InTru™ 3D Technology: | Nee |
Intel® Clear Video HD Technology (Intel® CVT HD): | Nee |
Intel® Insider™: | Nee |
Intel® Flex Memory Access: | Nee |
Intel® AES New Instructions (Intel® AES-NI): | Ja |
Enhanced Intel SpeedStep Technology: | Ja |
Execute Disable Bit: | Ja |
Idle States: | Ja |
Thermal Monitoring Technologies: | Ja |
CPU configuratie (max): | 2 |
Intel® Enhanced Halt State: | Ja |
Intel® Clear Video Technology for Mobile Internet Devices (Intel® CVT for MID): | Nee |
Intel® VT-x with Extended Page Tables (EPT): | Ja |
Ingebouwde opties beschikbaar: | Nee |
Intel® Secure Key: | Ja |
Intel® 64: | Ja |
Intel® OS Guard: | Ja |
Intel® Virtualization Technology for Directed I/O (VT-d): | Ja |
Intel® Clear Video-technologie: | Nee |
Intel® Virtualization Technology (VT-x): | Ja |
Verpakkingsgrootte processor: | 52.5 x 45 mm |
Conflictvrije processor: | Nee |
Intel® Identity Protection Technology (Intel® IPT): | Nee |
Versie Intel® Identity Protection Technology: | 0.00 |
Versie Intel® Secure Key Technology: | 1.00 |
ARK ID processor: | 83349 |
Intel® Trusted Execution Technology: | Ja |
Intel® TSX-NI: | Nee |
Versie Intel® TSX-NI: | 0.00 |
Compatibele besturingssystemen: | Microsoft Windows Server\r\nCanonical Ubuntu\r\nRed Hat Enterprise Linux (RHEL)\r\nSUSE Linux Enterprise Server (SLES)\r\nVMware |
Intel® Anti-Theft Technology (Intel® AT): | Nee |
Luchtvochtigheid bij opslag: | 0 - 95 procent |
Type behuizing: | Tower |
Maximaal intern geheugen ondersteund door processor: | 768 GB |
Geheugentypen ondersteund door processor: | DDR4-SDRAM |
Klokgeheugen-snelheden ondersteund door processor: | 1600 MHz |
ECC: | Ja |
Kloksnelheid geheugen: | 2133 MHz |
Geheugenslots: | 8 |
SSD interfaces: | Serial Attached SCSI (SAS) |
Ethernet interface type: | Gigabit Ethernet |
Aantal geïnstalleerde processoren: | 1 |
Geheugenbandbreedte ondersteund door de processor ( max): | 51 GB/s |
Chipset moederbord: | Intel C610 |
Schaalbaarheid: | 2S |
Hoogte, in bedrijf: | 0 - 3048 m |
Hoogte bij opslag: | 0 - 9144 m |
FSB Parity: | Nee |
Front-side bus processor: | - MHz |
Tcase: | 72.8 °C |
Intel® Demand Based Switching: | Ja |
Physical Address Extension (PAE): | 46 Bit |
Geheugenkanalen ondersteund door processor: | Quad |
Processorserie: | Intel Xeon E5-2600 v3 |
Intel® Dual Display Capable Technology: | Nee |
Intel® FDI Technology: | Nee |
Intel® Rapid Storage Technology: | Nee |
Intel® Fast Memory Access: | Nee |
RAID support: | Ja |
PCI Express x16 (Gen 3.x) slots: | 1 |
PCI Express x4 (Gen 3.x) slots: | 2 |
HDD omvang: | - " |
Maximale opslagcapaciteit: | - TB |
Ondersteunde opslagstationinterfaces: | SAS, Serial ATA |
Hot-plug ondersteuning: | Ja |
Intel® Virtualization Technology (Intel® VT): | VT-d, VT-x |
aantal QPI links: | 2 |
PCI Express x8 (Gen 3.x) slots: | 2 |
Aantal hoofdvoedingen: | 1 |
Wake-on-LAN: | Ja |
Compatibele processors: | Intel® Xeon® |
Max. aantal SMP-processoren: | 1 |
Wifi: | Nee |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 10 - 90 procent |
Intel® Matrix Storage Technology (Intel® MST): | Nee |
Prestatiebeheer: | HP iLO |
Intel® On-Demand Power Redundancy Technology: | Nee |
Intel® Local Control Panel: | Nee |
Heb je hulp nodig?
Als je hulp nodig hebt met HP ProLiant ML110 Gen9 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Server HP
23 November 2024
30 September 2024
22 Januari 2024
18 Juni 2023
9 Juni 2023
17 April 2023
6 April 2023
27 Maart 2023
24 Maart 2023
10 Maart 2023
Handleiding Server
- Telestar
- Freecom
- Gefen
- TAIDEN
- Atlantis Land
- Raidsonic
- Digi
- Kathrein
- Netgear
- Advantech
- GeoVision
- Areca
- Chenbro Micom
- Middle Atlantic
- Cisco
Nieuwste handleidingen voor Server
13 Juni 2025
8 Juni 2025
7 Juni 2025
2 Juni 2025
15 Mei 2025
1 Mei 2025
1 Mei 2025
2 April 2025
2 April 2025
28 Maart 2025