HP ProLiant DL320 G6 Handleiding

HP Server ProLiant DL320 G6

Lees hieronder de 📖 handleiding in het Nederlandse voor HP ProLiant DL320 G6 (105 pagina's) in de categorie Server. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/105
HP ProLiant DL320 G6 Server
User Guide
Part Number 530514-002
March 2010 (Second Edition)
© Copyright 2009, 2010 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP
shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft, Windows, and Windows Server are U.S. registered trademarks of Microsoft Corporation.
Intended audience
This document is for the person who installs, administers, and troubleshoots servers and storage systems.
HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards
in products with hazardous energy levels.
Contents
Component identification ............................................................................................................... 7
Front panel components ................................................................................................................................ 7
Front panel LEDs and buttons ......................................................................................................................... 8
SAS and SATA device numbers ..................................................................................................................... 8
Rear panel components 9 ................................................................................................................................
Rear panel LEDs and buttons ......................................................................................................................... 9
PCI expansion slot definitions ...................................................................................................................... 10
System board components ..........................................................................................................................10
System maintenance switch ............................................................................................................... 11
System board LEDs ..................................................................................................................................... 13
System LEDs and internal health LED combinations ......................................................................................... 14
Fan locations ............................................................................................................................................. 14
Operations................................................................................................................................. 16
Power up the server .................................................................................................................................... 16
Power down the server ............................................................................................................................... 16
Remove the server from the rack .................................................................................................................. 16
Remove the access panel ............................................................................................................................ 17
Remove the air baffle .................................................................................................................................. 17
Remove the PCI riser board assembly ........................................................................................................... 17
Install the PCI riser board assembly .............................................................................................................. 18
Setup ......................................................................................................................................... 20
Optional installation services ....................................................................................................................... 20
Rack planning resources ............................................................................................................................. 20
Optimum environment................................................................................................................................. 21
Space and airflow requirements ........................................................................................................21
Tempera ture requirements ................................................................................................................. 21
Power requirements .......................................................................................................................... 22
Electrical grounding requirements ...................................................................................................... 22
Rack warnings ........................................................................................................................................... 23
Identifying the server shipping carton contents ............................................................................................... 23
Installing hardware options ......................................................................................................................... 23
Installing the server into the rack .................................................................................................................. 24
Installing the operating system ..................................................................................................................... 25
Powering up and configuring the server ........................................................................................................ 25
Registering the server.................................................................................................................................. 25
Hardware options installation ....................................................................................................... 26
Introduction ............................................................................................................................................... 26
Memory options ......................................................................................................................................... 26
Memory subsystem architecture ......................................................................................................... 26
Single-, dual , and quad- -rank DIMMs ................................................................................................. 27
DIMM identification .......................................................................................................................... 27
Memory configurations ..................................................................................................................... 28
General DIMM slot population guidelines ........................................................................................... 29
Installing a DIMM ............................................................................................................................. 31


Product specificaties

Merk: HP
Categorie: Server
Model: ProLiant DL320 G6

Heb je hulp nodig?

Als je hulp nodig hebt met HP ProLiant DL320 G6 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Server HP

Handleiding Server

Nieuwste handleidingen voor Server