Honeywell TrueZONE HZ322 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell TrueZONE HZ322 (12 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 64 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
HZ322 TrueZONEÂŽ
Zone Panel Professional Installation Guide
69-2199-03
Installation Guide
Specifications ..................................................................................................................................
1
Accessories .....................................................................................................................................
1
Mounting ..........................................................................................................................................
2
Wiring ..............................................................................................................................................
3
Heat Pump ......................................................................................................................................
6
Basic Configuration .........................................................................................................................
7
Advanced Configuration ..................................................................................................................
8
Operation .........................................................................................................................................
9
Checkout .........................................................................................................................................
9
Warranty ........................................................................................................................................
10
SPECIFICATIONS
TABLE OF CONTENTS
Input Ratings:
Voltage: 18-30 VAC 50/60 Hz transformer of 40 VA
or more.
Current Draw:
Zone Panel: 7.5 VA max.
THM4000R Wireless Adapter: 2 VA max.
All VA specifications at 24 VAC.
Wiring:
18- or 20-gauge solid (not stranded) wire.
Humidity Ratings:
5% to 90% RH non-condensing.
Temperature Ratings:
Shipping: -20° to 150°F (-29° to 66°C)
Operating: -40° to 165°F (-40° to 74°C)
Dimensions:
See below.
Emissions:
Complies with FCC Class B, part 15 requirements.
Read and save these instructions.
Need Help?
For assistance with this product please visit http://customer.honeywell.com
and/or call Honeywell Zoning Hotline toll-free at 1-800-828-8367
ÂŽ U.S. Registered Trademark. US Patent No. 7,693,591; 7,904,830; 7,913,180; 7,904,830; 7,819,331; 7,766,246; 7,558,648 and other patents pending.
Copyright Š 2012 Honeywell International Inc. All rights reserved.
Fig. 1. HZ322 TrueZONE panel dimensions in in.
(mm).
M28011
1.86 (47)
8 (203)
11.5
(292)
HZ322 TrueZONE
1 69-2199—03
APPLICATION
ACCESSORIES
Table 1. Recommended Thermostats.
System Non-Programmable Programmable
Single-
Stage
TH5110D, TH3110D,
T87N
TH8110U, TH6110D,
TH4110D
Multi-
Stage
TH5220D TH8320U, TH8321U,
TH6220D, YTH9421C
Heat-
Pump
TH5220D
TH3210D
TH8320U
TH8321U
TH6220D
TH4210D
YTH9421C
Wire-
less*
TH5320R TH6320R
Note: All versions of the model numbers listed above
will work with the applications they're listed for.
* For RedLINK™ wireless devices, a THM4000 is
required.
Table 2. Recommended Dampers.
Type Honeywell
Damper
Round Rectangular
Zone Spring-open/
power-closed
ARD
(6VA)
ZD (6 VA)
Power-open/
power-closed
MARD/
RRD
(2 VA)
For recommended
dampers call the
Honeywell Zoning
Hotline at
1-800-828-8367.
Bypass -Static pres
sure regulating
damper
SPRD/
MARD
(2 VA)
SPRD
Table 3. Recommended Commercial Dampers.*
Type Actuation Round Rectangular
Zone Power-open/
power-closed
MARD D2 or D3 with
ML6161A2009*
Bypass Power-open/
power-closed
MARD
with SPC
D3 with
ML6161B2024*
and SPC
* Or equivalent damper and actuator.
Table 4. Accessories.
Accessory Description
40 VA transformer* AT140A1042*
75 VA transformer AT175A1008
Discharge Air Temperature
Sensor *
DATS C7735A1000*
SDCR** Slave Damper Control
Relay
Wireless Adapter*** THM4000R1000
Wireless Outdoor Air
Temperature Sensor***
C7089R1013
Portable Comfort Control*** REM5000R1001
RedLINK Internet
Gateway***
THM6000R1002
* Included in HZ322K kit.
** Use an SDCR (Slave Damper Control Relay) to
add additional dampers to a zone to surpass the
maximum Damper VA rating per Zone.
*** For RedLINK™ wireless devices, a THM4000 is
required.
The HZ322 TrueZONEÂŽ panel controls:
• Conventional gas, oil, or electric forced-air systems up to 2 stages heat and cool;
• Heat pump systems with single stage compressor and auxiliary heat, and two stage heat pumps with no auxiliary heat;
and two stage heat pumps with no auxiliary heat;
• 2 or 3 forced-air zones with wired thermostats, or wireless thermostats using THM4000R wireless adapter.
Please refer to TrueZONE Panel Frequently Asked Questions form 50-9694 for operating details.
http://customer.honeywell.com


Product specificaties

Merk: Honeywell
Categorie: Niet gecategoriseerd
Model: TrueZONE HZ322

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell TrueZONE HZ322 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Honeywell

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd