Honeywell Sundial RF2 Y9520Z Handleiding

Honeywell Temperatuurregelaar Sundial RF2 Y9520Z

Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell Sundial RF2 Y9520Z (34 pagina's) in de categorie Temperatuurregelaar. Deze handleiding was nuttig voor 24 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/34
User Guide
Y9520Z Sundial RF2 Pack 5
How to use:
ST9520C Wireless Enabled 2 zone Programmer
DT92E Wireless Room Thermostats
BDR91T Wireless Enabled Relay Box (if installed)
System Components
Energy EfïŹciency and the Environment
Home energy use is responsible for more than Πof the total UK carbon emissions
which contribute to climate change. Heating and hot water systems based on
boilers account for of this ïŹgure, so it is important to understand how your
controls can help to maximize energy efïŹciency while maintaining your comfort.
Your Programmer should be used in conjunction with appropriate temperature
controls. In order to save energy the following general points should be observed:
1. Ensure your system contains room thermostats in 2 seperate zones, and that
both are set to appropriate temperature levels: typically 20°C for the main
occupied zone and 18°C for the less occupied zone (typically the bedrooms).
2.
Programme your heating and hot water to be off when you are not in the house. If
you are concerned about possible frost damage to any exposed pipe work, it is
advisable to ïŹt a frost protection system – your installer can advise you about this.
3. Think about how you use your domestic hot water – if you have a storage
system, it is not necessary to have this switched on all the time, even when you
are in the house.
4. Consider the heat up times required for your central heating. Every home
responds differently when the heating is switched on. Adjust the start time so
that you are not cold when you get up in the morning. A shorter heat up time is
required for other heating periods.
5. In the evening, when the house is up to temperature, it is often possible to
switch off the heating up to an hour before you go to bed, without any noticeable
reduction in comfort.
This document is to be left with the user
and forms part of a Home Information Pack
This section is to be completed by the Installer
Honeywell Control Systems Ltd.
Arlington Business Park,
Bracknell
Berkshire
RG12 1EB
Technical Help Desk: 08457 678999
www.honeywelluk.com
50047645-006 A
© 2011 Honeywell International Inc.
PLEASE RESPECT YOUR ENVIRONMENT!
Take care to dispose of this product and any
packaging or literature in an appropriate way
WHAT IS A PROGRAMMER?
...an Explanation for Householders (as recommended by the Energy Savings Trust)
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and
domestic hot water on and off at the same time, while others allow the domestic hot water and heating to
come on and go off at different times. Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some
programmers you must also set whether you want the heating and hot water to run continuously, run under
the chosen ‘On’ and ‘Off’ heating periods, or be permanently off. The time on the programmer must be
correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean
Time and British Summer Time. You may be able to temporarily adjust the
heating programme, for example, ‘Override’, ‘Advance’, or ‘Boost’. These
are explained in the manufacturer’s instructions. The heating will not work
if the room thermostat has switched the heating off. And, if you have a hot-
water cylinder, the water heating will not work if the cylinder thermostat
detects that the hot water has reached the correct temperature.
WHAT IS A ROOM THERMOSTAT?
...an explanation for Householders (as recommended by the Energy Savings Trust)
A room thermostat simply switches the heating system on and off as necessary. It works by sensing
the air temperature, switching on the heating when the air temperature falls below the thermostat
setting, and switching it off once this set temperature has been reached. Turning a room thermostat to
a higher setting will not make the room heat up any faster. How quickly the room heats up depends on
the design of the heating system, for example, the size of boiler and radiators. Neither does the setting
affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the
room being controlled at a lower temperature, and saves energy. The heating system will not work if
a time switch or programmer has switched it off. The way to set and use your room thermostat is to
ïŹnd the lowest temperature setting that you are comfortable with, and then leave it alone to do its job.
The best way to do this is to set the room thermostat to a low temperature – say 18ÂșC – and then turn
it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust
the thermostat further. Any adjustment above this setting will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only one room thermostat to
control the whole house. But you can have different temperatures in individual rooms by installing
thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose
a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly
higher setting to make sure that even the coldest room is comfortable, then prevent any overheating
in other rooms by adjusting the TRVs.
Room thermostats need a free ïŹ‚ow of air to sense the temperature, so they must not be covered by
curtains or blocked by furniture. Nearby electric ïŹres, televisions, wall or table lamps may prevent the
thermostat from working properly.
Location
ST9520C
DT92E
Zone 1
(typically in living room or hallway)
DT92E
Zone 2
(typically in bedroom or upstairs hallway)
BDR91T
(If installed, typically next to boiler)
3
Contents
CONTROL OF YOUR SYSTEM
General Description of Controls in Your System 4 ...................................................
The way to use a Programmer 4 ..............................................................................
The way to use a Room Thermostat / Control of Your Boiler / Optimisation 5 .........
GETTING STARTED WITH YOUR ST9520C
Step 1: Setting the Date & Time............................................................................6
Step 2: Running a Built-in Programme 7 .................................................................
PROGRAMMING YOUR ST9520C
The Built-in Programmes / Your Personal Programme 8 ..........................................
Reviewing the Programme Times / Modifying the Zone 1 Programme 9 ................
Modifying the Zone 2 Programme / Disabling or Enabling Time Periods 11 ...........
OPERATING YOUR ST9520C
Choosing the Operating Mode 12 ...........................................................................
Overriding the Operation Without Changing the Programmes 12 ...........................
The Extra Hour Function / The Holiday Function 13 ................................................
Enquiry Mode 14 .....................................................................................................
FINE TUNING YOUR ST9520C
Changing from AM/PM Time Display to the 24 Hour Clock 15 ................................
Changing the Installer Parameters 15 .....................................................................
Optimisation ........................................................................................................17
BOILER SERVICE REMINDER
Countdown to Service / When Service is Due 18 ....................................................
Shut-down ...........................................................................................................19
OPERATING YOUR DT92E
Inquiring about the Set Temperature / Adjusting the Set Temperature 19 ...............
Switching Off / Display Updates / Heating Indicator / Frost Protection 20 ..............
DT92E OPERATING INDICATORS
Low Battery Indicator / Battery Replacement / RF Communications Indicator / Lockout
...21
DT92E ENERGY SAVING ECO FEATURE
Entering ECO Mode and Setting the Energy Saving Time Period 22 ......................
What Happens in ECO Mode? 22 ............................................................................
How to Exit ECO Mode 23 .......................................................................................
FINE TUNING YOUR DT92E
Changing the DT92E Installer Parameters 23 .........................................................
OPERATING YOUR BDR91T RELAY BOX (IF INSTALLED)
BDR91T Controls Layout / Automatic Operation 25 ................................................
Temporary Manual Override / Loss of Wireless Communications 25 ......................
FAQ AND TROUBLESHOOTING
Frequently Asked Questions 26 ...............................................................................
Troubleshooting Guide........................................................................................28
CONFIGURATION & SERVICE DATA
ConïŹguration Data (to be completed by Installer) 31 .............................................


Product specificaties

Merk: Honeywell
Categorie: Temperatuurregelaar
Model: Sundial RF2 Y9520Z

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell Sundial RF2 Y9520Z stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Temperatuurregelaar Honeywell

Handleiding Temperatuurregelaar

Nieuwste handleidingen voor Temperatuurregelaar