INSTALLATION INSTRUCTIONS
69-2518-03
HE220, HE260 Humidifier
Installation Kit
WELCOME
To the comfortable world of humidified air. When you use
your Honeywell humidifier, you notice that your skin is not
as dry, and that your scratchy throat and irritated nasal
passages that aggravate allergies and asthma are
steadily improving.
You have also taken the first step in reducing the zapping
you create when you walk on your carpet and then touch
your TV, computer, metal door knob or your pet. Your
furniture and woodwork are also benefitting from the
difference that humidified air makes.
Congratulations! You have just made a great investment
in improving the comfort of your home.
APPLICATION
This installation kit contains all the parts necessary to
install your new Honeywell HE220 or HE260 Humidifier.
INSTALLATION
Preparing for the Installation
Be sure to identify all the required (Table 1) accessories
(included) and make sure the appropriate tools are
available before beginning the installation.
Required Accessories (Included)
Table 1. Required Accessories.
Quantity Accessory
Humidifier Parts and Accessories
3 ft
(0.93 m)
Bypass ducting including:
6 in. (155 mm) diameter flexible duct
Starter collar
Summer shut-off damper
Duct tape
20 ft
(6.2m)
18 gauge, two-strand thermostat wire
20 ft
(6.2m)
1/4 in. (6.35 mm) OD feed water tubing
10 ft
(3.1m)
1/2 in (12.7 mm) ID drain tubing
1 bag Connecting and mounting hardware:
Wire nuts (4)
No. 8 sheet metal screws (18)
Drain tube clamps (2 sizes)
Feed tube mounting clamps (6)
Brass inserts (2)
Plastic compression rings (2)
1 Plug-in transformer
HE220, HE260 HUMIDIFIER INSTALLATION KIT
69-2518—03 2
Required Tools
Tools required for installation include:
• Tin snip.
• Screwdriver.
• Adjustable or open-end wrench.
• Drill, punch or awl.
• Level.
• 3/4-in. Sheet Metal Drill Bit
Determining Best Location for
Humidifier
• Select a location for the humidifier on the supply (warm
air stream) or the return plenum. See Fig. 1.
• Select a location for the bypass on the opposite
plenum. The sidewalls of the humidifier are
interchangeable to allow bypass duct mounting on
either side of the humidifier.
• Select a location that cannot damage the air
conditioner A-coil during installation.
• Select a location where the 6 ft (1.86m) of 6 in. (155
mm) duct provided is adequate to connect the
humidifier to the bypass.
— Do not locate the humidifier or bypass on a fur-
nace body.
— Allow adequate clearance in front of and above
the humidifier so you can easily remove the cover
to perform routine maintenance.
— Mount humidifier at least 3 in. (78 mm) above the
furnace body to allow adequate space for the
solenoid valve and drain line.
— Mount humidifier in a conditioned space to prevent
freezing.
Fig. 1. Typical humidifier installation locations.
Selecting Water Supply Location
• Use either hard or soft water in the humidifier and
either hot or cold water. The water flow rate, with the
humidifier running, is 3.5 gal/hr (13 liters/hr) to flush
the pad and provide moisture for evaporation.
• Make sure that the 20 ft (6.2m) of feed water tubing
provided is adequate to connect the water supply
(saddle valve) with the humidifier solenoid valve.
Locating Closest Floor Drain
• Select location with access to a floor drain to provide
drainage for air conditioner condensation and
humidifier drainage.
• If you do not have a drain available, we recommend
that you install the Honeywell Whole House Drum or
Disk Humidifier.
• Make sure that the 10 ft (3.1m) of drain tubing is
adequate to reach from the humidifier drain connection
to the floor drain.
Mount the switch at least 6 in. (152 mm) upstream from
an elbow or junction, and at least 15 in. (381 mm)
downstream from an elbow or junction. Locate the switch
on the opposite side of the duct from the air entrance.
(See Fig. 1-3 in S688 Installation Instructions.)
Selecting Location for Humidistat
• Select a location for the humidistat on the return
plenum or on the wall in the living space.
— Mounting on the return plenum is the easiest
installation for the control wiring circuit.
For return duct mounting, the humidistat should be
mounted upstream from the humidifier or bypass so that it
is properly sensing the relative humidity of the living
space. Locate the control at least 8 in. (203 mm)
upstream from the humidifier in the return air duct. (See
Fig 2.)
Air Pressure Switch and Accessories
2 Black rubber gasket
2 Tubing Fitting Elbow
1 10 ft. Tubing, 1/4 in. ID
1 Air Pressure Switch (Fig. 10)
2 Screws, #8 x 3/4 in. sheet metal
2 Terminal Adaptor
Table 1. Required Accessories.
Quantity Accessory
M27302
M27323
M12248D
HORIZONTAL
DOWN
FLO
LOWBOY
HIGHBOY
HUMIDIFIER
BYPASS
COLLAR
HE220, HE260 HUMIDIFIER INSTALLATION KIT
3 69-2518—03
Fig. 2. Selecting duct location for humidistat.
Locating Closest 120V Electrical Outlet
• Select location with access to an outlet. If not
available, contact an electrician to have one installed.
Make sure that the 20 ft (6.2m) of thermostat wire is
adequate to reach from the humidifier solenoid, to the
sail switch, to the humidistat, to the plug-in transformer
in the outlet.
INSTALLING HUMIDIFIER
WARNING
Hazardous Voltage.
Can cause personal injury or equipment
damage.
Do not cut or drill into any air conditioning or
electrical accessory.
CAUTION
Sharp Edges Installation Hazard.
Can cause personal injury.
Wear gloves and safety glasses.
1. Turn off power to the air handing system at the cir-
cuit breaker.
2. Draw a level line on the plenum in the location
chosen for the humidifier. (Leveling assures optimal
humidifier performance.)
3. Locate the template in the Humidifier Installation
Instructions.
4. Tape the template in position and trace around the
template.
5. Remove the template and carefully cut the rectan-
gular opening.
6. Disassemble the humidifier; remove the cover and
take out the humidifier pad assembly. See Fig. 3.
NOTE: Sidewalls are interchangeable for either left or
right bypass installation. To change direction,
remove the screws holding each sidewall,
reverse sidewall locations, and reinstall the
screws.
Fig. 3. Disassembling humidifier.
7. Make sure the humidifier housing is level, then posi-
tion it in the opening so the plastic tabs are in place
on the lower sheet metal edge of the opening. Use
pliers, as necessary, to flatten cut edges. See Fig.
4.
8. Secure the humidifier housing to the opening at the
top and bottom using sheet metal screws.
Fig. 4. Installing humidifier on duct.
9. Use the 6 in. (155 mm) starter collar as a template
to mark the opening for the bypass.
10. Carefully cut the opening for a 6 in.(155 mm) starter
collar. See Fig. 5. Use a drill, punch or awl to start
the cut in the middle of the circle. Cut in an outward
spiral to assist in controlling the cut.
ALTERNATE LOCATION
RETURN
AIR
RETURN
AIR
6 in. (152 mm)
MINIMUM 15 in. (381 mm)
MINIMUM
BEST
LOCATION
RETURN AIR DUCT M12831
M12304A
WATER
FEED NOZZLE
FRAME
HUMIDIFIER
HOUSING
WATER
FEED TUBE
HUMIDIFIER
PAD ASSEMBLY
COVER
SIDEWALL
BY-PASS SIDEWALL
DUCT
LEVEL
SHEET METAL
SCREWS (4)
PLASTIC
TABS (2)
DRAIN TUBING M20171
OPENING
TO AIR DUCT


Product specificaties