Honeywell HCM-750 Series Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell HCM-750 Series (40 pagina's) in de categorie Luchtbevochtiger-Luchtontvochtiger. Deze handleiding was nuttig voor 47 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/40
HONEYWELL
EASY TO CARE TOP FILL
EVAPORATIVE HUMIDIFIER
MODEL HCM-750 Series
IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE SAFETY
INSTRUCTIONS BEFORE USING
THIS HUMIDIFIER
When using electrical appliances, basic pre-
cautions should always be followed to reduce
the risk of fire, electric shock, and injury to
persons, including the following
1. Always place this humidifier on a firm, flat and
level surface. This humidifier may not work
properly on an uneven surface.
2. Place this humidifier in an area where it is not
accessible to children.
3. Do not place the humidifier near any heat
sources such as stoves, radiators, and heaters.
4. Do not use the humidifier outdoors.
5. Before using the humidifier, check the power
cord for any signs of damage. If the cord is
found to be damaged, DO NOT USE and return
the humidifier to the manufacturer under the
warranty agreement for repair.
6. This appliance has a polarized plug (one blade
is wider than the other). To reduce the risk of
shock, this plug is intended to fit only one way
in a polarized outlet. If the plug does not fit
securely in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature.
7. To disconnect the humidifier, first turn controls
to the OFF position, then grip the plug and pull
it from the wall outlet. Never pull by the cord.
8. A loose fit between the AC outlet (receptacle)
and plug may cause overheating and a
distortion of the plug. Contact a qualified
electrician to replace loose or worn outlet.
9. The humidifier should always be unplugged
and emptied when not in operation or while
being serviced or cleaned.
10. Never tilt or attempt to move the humidifier
while it is operating or filled with water.
UNPLUG the humidifier before moving.
11. This humidifier requires regular cleaning. Refer
to the CLEANING instructions provided. Never
clean the humidifier in any manner other than
as instructed in this manual.
12. Do not direct moisture flow directly at
individuals, walls or furniture.
13. When a humidifier is used in a closed room
or small rooms, check periodically for proper
ventilation, as excessive humidity can cause
condensation stains on walls.
14. Turn the humidifier OFF if you notice moisture
on the inside of your windows. For proper
humidity reading use a hygrometer, which is
available in many hardware and department
stores, or by ordering one from
the manufacturer.
15. This product is intended for residential
use only.
The Honeywell trademark is used by Kaz, Inc. under license from Honeywell International Inc.
Honeywell International Inc. makes no representation or warranties with respect to this product.
2
INTRODUCTION
How it Works:
The Easy to Care Evaporative Humidifier is designed to quietly provide invisible cool moisture.
Water is pumped from the water reservoir through the water flow channel. Water is dispersed
from water flow channel into the wicking filter which helps remove minerals and impurities
from the water. A fan quietly pushes moisture out of the wick and into the air in the form of an
ultra fine invisible mist.
The unique top fill design makes filling as easy as watering a plant. This unit is also equipped
with a water circulating feature which helps indicate when refilling is needed.
Your humidifier is made up
of these parts:
Water Hose
Main Housing
On/Off Switch
Water Window
Water Pump
Pump Outlet
Moisture Output Switch
Main Housing Water Fill Bafel
Clear Protective Cover
Top Grille
Wicking Filter
Wicking Filter Tray
Water Outlet
Fill Funnel
3
SETTING UP YOUR HUMIDIFIER
Placement
Select a firm, level location at least 6" (15cm) from any
walls for proper airflow. Place the humidifier on a water-
resistant surface, as water can damage furniture and some
flooring.
Kaz will not accept responsibility for property damage
caused by water spillage.
Filling
Fill pitcher or jug with up to
1.5 gallon of cool water.
Note: You can fill this
humidifier with as much
as 1.5 gallon of water or
as little as a cup of water.
Pour water into the fill funnel
area located on the top of
the unit.
Indications that your humidifier
needs to be refilled are:
- Water will stop circulating
through the water channel.
- Your humidifier will start to
sound louder.
- Water level is not visible in
water window or below the
refill line
Figure 1
Figure 2
Remove from box
Remove packaging material. Remove and set aside instruction
manual. Recycle box and packaging materials or save box for
end of season storage.
To prevent water pump from shifting during transportation
it has been taped to the inside of your humidifier. Remove
grille and filter tray and locate the water pump on the bottom
of the main housing. Remove shipping tape located on water
pump and place water pump back in slot.
Replace filter tray and grille on top of main housing.
Make sure it is securely in place and hose is not bent or
crimped or unit will not operate.


Product specificaties

Merk: Honeywell
Categorie: Luchtbevochtiger-Luchtontvochtiger
Model: HCM-750 Series

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell HCM-750 Series stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Luchtbevochtiger-Luchtontvochtiger Honeywell

Handleiding Luchtbevochtiger-Luchtontvochtiger

Nieuwste handleidingen voor Luchtbevochtiger-Luchtontvochtiger