Hitachi RAS-24LH1 Handleiding

Hitachi Airco RAS-24LH1

Lees hieronder de 📖 handleiding in het Nederlandse voor Hitachi RAS-24LH1 (51 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 21 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/51
1
ENGLISH
INDOOR UNIT/OUTDOOR UNIT
MODEL
RAS-18LH1/RAC-18LH1
RAS-24LH1/RAC-24LH1
OUTDOOR UNIT INDOOR UNIT
Instruction manual Page 1~24
To obtain the best performance, please read this instruction manual completely.
Инструкция по эксплуатации
стр. 25~48
Для правильной работы данного устройства обязательно полностью прочитайте данную инструкцию.
RAS-18LH1
RAS-24LH1
SPLIT TYPE AIR CONDITIONER
RAC-18LH1
RAC-24LH1
2
!
SAFETY PRECAUTION
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air ow for your health.
W
A
R
N
I
N
G
!
Do not insert a nger, a rod or other objects into the air outlet or inlet. As
the fan is rotating at a high speed, it will cause injury. Before cleaning, be
sure to stop the operation and turn the breaker OFF.
During thunder storm, disconnect and turn off the circuit breaker.
Do not use any conductor as fuse wire, this could cause fatal accident.
!
Make sure to connect earth line.
Indicates the instructions that must be followed.
The sign in the gure indicates prohibition.
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of Warningand Caution”. The Warning” section contains matters which,
if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The sign indicate the following meanings.
Please keep this manual after reading.
WARNING
PRECAUTIONS DURING INSTALLATION
Do not reconstruct the unit.
Water leakage, fault, short circuit or re may occur if you reconstruct the unit by
yourself.
Please ask your sales agent or qualifi ed technician for the installation of your unit.
Water leakage, short circuit or re may occur if you install the unit by yourself.
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the
earth line of telephone. Improper installation of earth line may cause electric
shock.
Be sure to use the specifi ed piping set for R410A. Otherwise, this may result in
broken copper pipes or faults.
A circuit breaker should be installed depending on the mounting site of the unit.
Without a circuit breaker, the danger of electric shock exists.
Do not install near location where there is ammable gas. The outdoor unit may
catch re if ammable gas leaks around it.
Please ensure smooth ow of water when installing the drain hose.
CAUTION
!
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
Should abnormal situation arises (like burning smell), please stop operating the unit
and turn off the circuit breaker. Contact your agent. Fault, short circuit or re may
occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause
electric shock and re.
Please contact your agent if you need to remove and reinstall the unit. Electric
shock or re may occur if you remove and reinstall the unit yourself improperly.
If the supply cord is damaged, it must be replaced by the special cord
obtainable at authorized service/parts centers.
W
A
R
N
I
N
G
!
!
3
ENGLISH
PRECAUTIONS DURING OPERATION
Do not attempt to operate the unit with wet hands, this could cause fatal
accident.
When operating the unit with burning equipments, regularly ventilate the
room to avoid oxygen insuffi ciency.
Do not direct the cool air coming out from the air-conditioner panel to face
household heating apparatus as this may affect the working of apparatus
such as the electric kettle, oven etc.
Do not place plants directly under the air ow as it is bad for the plants.
Please ensure that outdoor mounting frame is always stable, rm and
without defect. If not, the outdoor unit may collapse and cause danger.
Do not splash or direct water to the body of the unit when cleaning it as
this may cause short circuit.
When operating the unit with the door and windows opened, (the room humidity is always above
80%) and with the air defl ector facing down or moving automatically for a long period of time,
water will condense on the air defl ector and drips down occasionally. This will wet your furniture.
Therefore, do not operate under such condition for a long time.
If the amount of heat in the room is above the cooling or heating capability of the unit (for
example: more people entering the room, using heating equipments and etc.), the preset room
temperature cannot be achieved.
This appliance is not intended for use by young children or infi rm persons unless they have been
adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
Do not climb on the outdoor unit or put objects on it.
Please switch off the unit and turn off the circuit breaker during cleaning,
the high-speed fan inside the unit may cause danger.
Turn off the circuit breaker if the unit is not to be operated for a long period.
C
A
U
T
I
O
N
!
The product shall be operated under the manufacturer specifi cation and
not for any other intended use.
Do not put water container (like vase) on the indoor unit to avoid water
dripping into the unit. Dripping water will damage the insulator inside the
unit and causes short-circuit.
Do not use any aerosol or hair sprays near the indoor unit. This chemical
can adhere on heat exchangern and blocked the evaporation water
ow to drain pan. The water will drop on tangential fan and cause water
splashing out from indoor unit.


Product specificaties

Merk: Hitachi
Categorie: Airco
Model: RAS-24LH1

Heb je hulp nodig?

Als je hulp nodig hebt met Hitachi RAS-24LH1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Hitachi

Handleiding Airco

Nieuwste handleidingen voor Airco