Haier Tempo Series 1U12TE1VHA Handleiding
Haier
Niet gecategoriseerd
Tempo Series 1U12TE1VHA
Lees hieronder de 📖 handleiding in het Nederlandse voor Haier Tempo Series 1U12TE1VHA (12 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 5 personen en werd door 3 gebruikers gemiddeld met 4.9 sterren beoordeeld
Pagina 1/12

Ductless HVAC
Quick Reference Guide
Plus

*Remote controller is shipped with indoor unit.
**Requires WK-B adapter.
Plus
Max Operating Range
Cooling: 14~115°F (-10~46°C) Heating: -15~75°F (-26-24°C)
Cooling below 23°F (-5°C) requires wind bae.
Size
Outdoor
Model
Indoor Model AHRI#
Max
Heat @
5
o
F
SEER2/EER2/
HSPF2 (IV)
Line Set:
Liquid
Suction
Min/
Max Line
Length
Max Fuse
Size A
Min Circuit
Amp
WiFi SmartHQ
Standard
Controller
Optional
Controller
9K 1U09AP2HDB AW09AP2HDB 211709317 8,500 23.5/14.5/9.6 1/4"- 3/8" 10’/50’ 15 11
WJ01X24721*
QACT17A**
YR-E16B**
YR-E17**
12K 1U12AP2HDB AW12AP2HDB 211709318 10,400 23/12.5/10.5 1/4"- 3/8" 10’/50’ 15 11
15K 1U15AP2HDB AW15AP2HDB 211709319 14,200 21.5/12.5/9.6 1/4"- 1/2" 10’/83’ 20 14
18K 1U18AP2HDB AW18AP2HDB 211709320 15,400 21/12.5/9.6 1/4"- 1/2" 10’/83’ 20 14
24K 1U24AP2HDB AW24AP2HDB 211709321 20,000 20/12.5/9.6 1/4"- 1/2" 10’/83’ 30 20
Max Operating Range
09/12/18EH2HEB: Cooling: 14~115°F (-10~46°C) Heating: -31~75°F (-35-24°C)
24/3036LP2HDA: Cooling: -4°F~115°F (-20~46°C) Heating: -15°F~75°F (-26~46°C)
Cooling below 23°F (-5°C) requires wind bae.
Size Outdoor Model Indoor Model AHRI#
Max
Heat
@ 5
o
F
SEER2/EER2/
HSPF2 (IV)
Line Set
1
:
Liquid
Suction
Min/
Max Line
Length
Max Fuse
Size A
Min Circuit
Amp
WiFi
SmartHQ
Standard
Controller
Optional
Controller
9K 1U09EH2HEB AW09EH2HEB 212409447 10,600 30/16/14 1/4"- 1/2" 10’/50’ 15 13
WJ26X27153*
QACT17A
YR-E16B
YR-E17
12K 1U12EH2HEB AW12EH2HEB 212409448 14,900 27.5/15/12.5 1/4"- 1/2" 10’/50’ 20 14
18K 1U18EH2HEB AW18EH2HEB 212409449 18,000 23/13/12 1/4"- 1/2" 10’/83’ 30 20
24K 1U24LP2HDA AW24TL2HFA 211744601 22,000 21/11/10 3/8" - 5/8" 10’/165’ 25 21
30K 1U3036LP2HDA AW30TL2HFA 211744603 25,800 19/8.8/9 3/8" - 5/8" 10’/165’ 30 26
36K 1U3036LP2HDA AW36TL2HFA 211744606 26,200 18/8.2/9 3/8" - 5/8" 10’/165’ 30 26
Highwalls
Max Operating Range
9/12TE1VHA: Cooling: 14~115°F (-10~46°C) Heating: -4~75°F (-20-24°C)
09/12TE2VHA, 09/12/18/24TE2HDA: Cooling: 14~115°F (-10~46°C) Heating: -4~75°F (-20-24°C)
24/30/36TL2HFA: Cooling: -40~115°F (-40~46°C) Heating: -4~75°F (-20-24°C)
Cooling operating range varies by model. Cooling below 23°F (-5°C) requires wind bae.
Size
Outdoor
Model
Indoor
Model
AHRI#
Max
Heat
@ 5
o
F
SEER/
EER/ HSPF
SEER2/EER2/
HSPF2 (IV)
Line Set:
Liquid
Suction
Min/
Max Line
Length
Max
Fuse
Size A
Min
Circuit
Amp
WiFi SmartHQ
Standard
Controller
Optional
Controller
9K 1U09TE1VHA AW09TE1VHA 10191421 6,600 16/11/9 17.5/10.5/9.5 1/4"- 3/8" 10’/66’ 20 18
WJ01X24721*
QACT17A**
YR-E16B**
YR-E17**
(See note, below)
12K 1U12TE1VHA AW12TE1VHA 10191422 8,000 16/11/9 17/9.5/9 1/4"- 3/8" 10’/66’ 20 18
9K 1U09TE2VHA AW09TE2VHA 206551253 6,000 18/11/10 -- 1/4"- 3/8" 10’/66’ 15 12
12K 1U12TE2VHA AW12TE2VHA 206551254 8,500 18/11/10 -- 1/4"- 3/8" 10’/66’ 15 12
9K 1U09TE2HDA AW09TC2HDA 210715479 7,000 18/11/10 19/11/9 1/4"- 3/8" 10’/66’ 15 12
WJ01X24721*
QACT17A
YR-E16B
YR-E17
12K 1U12TE2HDA AW12TC2HDA 210715480 8,400 18/11/10 19/11/9.2 1/4"- 3/8" 10’/66’ 15 12
18K 1U18TE2HDA AW18TC2HDA 209938278 13,000 19/11/10 19/11/9 1/4”- 1/2” 10’/83’ 25 18
24K 1U24TE2HDA AW24TC2HDA 209938279 16,700 19/9.5/10 19/9.5/9 1/4"- 1/2" 10’/83’ 30 23
24K 1U24TL2HFA AW24TL2HFA 207769097 21,800 20/11/10 20/11/9.5 3/8”-5/8” 10’/165’ 30 27
30K 1U3036TL2HFA AW30TL2HFA 207769098 21,800 18/9.5/9.5 18/9.5/9 3/8”-5/8” 10’/165’ 40 27
36K 1U3036TL2HFA AW36TL2HFA 207769099 22,000 17.5/8/9.5 17.5/8/9 3/8”-5/8” 10’/165’ 40 27
115V
Low
Ambient
Cooling
NOTE: WK-B controller adapter not required for AW**TC2HDA models
Single-Zone Systems
Quick Reference Guide
1
See also Arctic Single Zone Piping Specications and Adapter Requirements
Built-in WiFi
Adaptable with WiFi Adapter QAWF01A
Product specificaties
Merk: | Haier |
Categorie: | Niet gecategoriseerd |
Model: | Tempo Series 1U12TE1VHA |
Heb je hulp nodig?
Als je hulp nodig hebt met Haier Tempo Series 1U12TE1VHA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Haier

6 Juni 2025

5 Juni 2025

5 Juni 2025

2 Juni 2025

28 Maart 2025

10 December 2024

10 December 2024

10 December 2024

10 December 2024
Handleiding Niet gecategoriseerd
- Niet gecategoriseerd Dobar
- Niet gecategoriseerd VAIS Technology
- Niet gecategoriseerd Hubelino
- Niet gecategoriseerd Jonsered
- Niet gecategoriseerd Eufy
- Niet gecategoriseerd Wilson
- Niet gecategoriseerd Kenwood
- Niet gecategoriseerd Leitz
- Niet gecategoriseerd Nxg
- Niet gecategoriseerd PreSonus
- Niet gecategoriseerd DoorBird
- Niet gecategoriseerd Murr Elektronik
- Niet gecategoriseerd Festool
- Niet gecategoriseerd Orava
- Niet gecategoriseerd Doro
Nieuwste handleidingen voor Niet gecategoriseerd

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025

6 Juni 2025