Grundfos JP 3-42 Handleiding

Grundfos Pomp JP 3-42

Lees hieronder de 📖 handleiding in het Nederlandse voor Grundfos JP 3-42 (19 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/19
JP and JP Booster
Installation and operating instructions
GRUNDFOS INSTRUCTIONS
English (GB) Installation and operating instructions
Original installation and operating instructions
Table of contents
1. General information . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Target group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Hazard statements . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. Receiving the product. . . . . . . . . . . . . . . . . . . . . . . 5
2.1 Inspecting the product . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Scope of delivery, JP . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Scope of delivery, JP Booster . . . . . . . . . . . . . . . . . . . 6
3. Installing the product . . . . . . . . . . . . . . . . . . . . . . . 6
3.1 Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.2 Mechanical installation . . . . . . . . . . . . . . . . . . . . . . . 6
3.3 Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . 8
4. Startup of the product . . . . . . . . . . . . . . . . . . . . . . 10
4.1 Priming the product . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2 Starting up the product 11. . . . . . . . . . . . . . . . . . . . . .
5. Product introduction 11. . . . . . . . . . . . . . . . . . . . . . .
5.1 Product overview, JP . . . . . . . . . . . . . . . . . . . . . . . 12
5.2 Product overview, JP Booster . . . . . . . . . . . . . . . . . . 12
5.3 Intended use 12. . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4 Pumped liquids . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.5 Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6. Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.1 Maintenance 13. . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2 Maintaining the pressure tank . . . . . . . . . . . . . . . . . . 13
6.3 Service kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7. Taking the product out of operation . . . . . . . . . . . . . 14
7.1 Draining JP and JP PT-V . . . . . . . . . . . . . . . . . . . . . 14
7.2 Draining JP PT-H. . . . . . . . . . . . . . . . . . . . . . . . . . 14
7.3 Storage of the product 14. . . . . . . . . . . . . . . . . . . . . . .
7.4 Frost protection 14. . . . . . . . . . . . . . . . . . . . . . . . . . .
8. Fault finding the product . . . . . . . . . . . . . . . . . . . . 14
8.1 The pump does not start . . . . . . . . . . . . . . . . . . . . . 15
8.2 The pump stops unexpectedly during operation and
starts again after a while . . . . . . . . . . . . . . . . . . . . . 15
8.3 The pump runs, but does not deliver the expected
amount of water . . . . . . . . . . . . . . . . . . . . . . . . . . 15
8.4 Fault finding boosters with a pressure manager . . . . . . . 15
8.5 Fault finding boosters with a pressure tank . . . . . . . . . . 16
9. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9.1 Operating conditions. . . . . . . . . . . . . . . . . . . . . . . . 17
9.2 Head and flow rate . . . . . . . . . . . . . . . . . . . . . . . . . 17
9.3 Inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9.4 Miscellaneous data . . . . . . . . . . . . . . . . . . . . . . . . 17
10. Disposing of the product . . . . . . . . . . . . . . . . . . . . 17
1. General information
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction
concerning use of the appliance in a safe way and
understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children without
supervision.
Read this document before you install the product.
Installation and operation must comply with local
regulations and accepted codes of good practice.
1.1 Target group
These installation and operating instructions are intended for
professional as well as non-professional users.
1.2 Hazard statements
The symbols and hazard statements below may appear in Grundfos
installation and operating instructions, safety instructions and
service instructions.
DANGER
Indicates a hazardous situation which, if not avoided, will
result in death or serious personal injury.
WARNING
Indicates a hazardous situation which, if not avoided,
could result in death or serious personal injury.
CAUTION
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate personal injury.
The hazard statements are structured in the following way:
SIGNAL WORD
Description of the hazard
Consequence of ignoring the warning
Action to avoid the hazard.
1.3 Notes
The symbols and notes below may appear in Grundfos installation
and operating instructions, safety instructions and service
instructions.
Observe these instructions for explosion-proof products.
A blue or grey circle with a white graphical symbol
indicates that an action must be taken.
A red or grey circle with a diagonal bar, possibly with a
black graphical symbol, indicates that an action must not
be taken or must be stopped.
If these instructions are not observed, it may result in
malfunction or damage to the equipment.
Tips and advice that make the work easier.
2. Receiving the product
2.1 Inspecting the product
On receipt of the product, do the following:
1. Check that the product is as ordered.
If the product is not as ordered, contact the supplier.
2. Make sure that the supply voltage and frequency correspond to
the values stated on the product nameplate.
Related information
5.5.1 Nameplate example for JP and JP Booster
2.2 Scope of delivery, JP
The box contains the following items:
1 Grundfos JP pump
1 lifting-handle kit
1 quick guide
1 safety instructions booklet.
5
English (GB)
2.3 Scope of delivery, JP Booster
The box contains the following items:
1 Grundfos JP Booster
1 quick guide
1 safety instructions booklet.
3. Installing the product
3.1 Location
The product can be installed both indoors and outdoors. Use a
suitable cover to protect the product from direct sunlight, rain or
snow.
Please observe the following:
Install the product in a well-ventilated location to ensure cooling
of its components.
Install the product to enable easy inspection, maintenance and
service.
We recommend that you place the product as close to the
liquid to be pumped as possible.
We recommend that you install the product near a drain or in a
drip tray connected to a drain in order to lead away possible
condensation from cold surfaces.
Related information
3.1.2 Ambient temperature during operation
3.1.1 Installation of the product in a frosty environment
Protect the product from freezing if it is to be installed outdoors
where frost may occur.
3.1.2 Ambient temperature during operation
The ambient temperature must not exceed 55 °C.
Ambient temperature
Up to 40
°C The pump can run continuous operation.
40 to 55
°C
The overheating protection ensures that the pump
runs intermittent operation when the air temperature
is too high to cool the motor efficiently.
Example of intermittent cycle: the pump runs for 20
minutes and stops for 40 minutes before it starts
again. See the table below.
Intermittent operation (S3 mode)
40-55 °C 50 Hz 60 Hz
JP 3-42 ON: 20 min
OFF: 40 min
ON: 20 min
OFF: 40 min
JP 4-47 ON: 15 min
OFF: 45 min
ON: 10 min
OFF: 50 min
JP 4-54 ON: 20 min
OFF: 40 min
ON: 20 min
OFF: 40 min
JP 5-48 ON: 20 min
OFF: 40 min
ON: 30 min
OFF: 30 min
Related information
3.1 Location
3.1.3 Minimum space
Ensure sufficient space for service and maintenance and for motor
cooling.
We recommend a clearance of 0.5 m on three sides of the
product.
The motor is fan cooled, so do not block the fan cover.
If you install the product with one side against a wall, make
sure that the nameplate is visible.
3.2 Mechanical installation
WARNING
Electric shock
Death or serious personal injury
Switch off the power supply before you start any work
on the product.Make sure that the power supply cannot
be switched on accidentally.
CAUTION
Crushing of feet
Minor or moderate personal injury
Wear safety shoes when handling the product.
CAUTION
Impurities in the water
Minor or moderate personal injury
Before the pump is used for supplying drinking water,
flush the pump thoroughly with clean water.
3.2.1 Mounting the product
Place the product in a horizontal position with a maximum
inclination angle of ± 5 °. The base plate must be facing
downwards.
Fasten the product to a solid horizontal foundation by means of
screws through the holes in the base plate.
F G
TM072334
Fig. Foundation of a JP pump
F G
TM072477
Fig. Foundation of JP PT-H Booster
JP pump
[mm]
JP PT-H Booster
[mm]
F 47 265
G 110 230
3.2.2 Attaching the lifting handle
The handle is supplied with the JP pump. It is optional to attach the
handle on the pump, for example on permanently installed pumps.
6
English (GB)


Product specificaties

Merk: Grundfos
Categorie: Pomp
Model: JP 3-42

Heb je hulp nodig?

Als je hulp nodig hebt met Grundfos JP 3-42 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Pomp Grundfos

Handleiding Pomp

Nieuwste handleidingen voor Pomp