Gira Basic Q Handleiding

Gira Rookmelder Basic Q

Lees hieronder de 📖 handleiding in het Nederlandse voor Gira Basic Q (3 pagina's) in de categorie Rookmelder. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
For your safety
Serious injury e.g. caused by an electric
shock, fire, or material damage are possible
in case of improper assembly. Read and
observe these instructions completely.
Product features
The smoke alarm device Dual Q is a battery-
operated combination of smoke and heat
alarm device for private residential units or
similarly inhabited areas as per DIN 14676.
The smoke alarm device Dual Q detects the
development of smoke in a timely manner
and warns occupants before the smoke gas
concentration becomes dangerous. The
warning comes in the form of acoustic
(tone) and optical (LED) signals.
• Loud, pulsating alarm signal
(at least 85 dB (A)).
• Fire and heat alarms alerted differently.
• Muffled alarm signal (approx. 75 dB (A))
during function test.
• Smoke detection by photoelectric
scattering principle.
• Heat detection via maximum and
differential function.
• Integrated function button for alarm
acknowledgement, function test and
muting, for example.
• Smoke detection can be switched off.
• Automatic smoke evaluation self-test
with tracking of soiling.
• "Fouling/malfunction" indication.
• Signalling of technical faults can be
delayed up to 12 h in darkness.
• Up to 40 smoke alarm devices can be
networked on each wire.
Electrical devices may only be
installed and connected by a
qualified electrician!
Configuration and installation may
only be performed by an expert
As per DIN 14676, configuration, installation
and maintenance of the smoke alarm device
may only be performed by a qualified expert.
For this purpose, Gira offers the "Certified
expert for smoke alarm devices in accor-
dance with DIN EN 14676" online course,
complete with certificate.
More detailed information can be found
under "akademie.gira.de".
• One module interface for three optional
modules with simultaneous use of the
networking terminal
• Meets requirements of the new Q Label
quality seal
Q Label means
• Tested longevity of the smoke alarm
device (up to 10 years after activation)
• Fewer false alarms
• Increased stability, e.g. against external
factors
• Permanently installed, non-removable
battery
Scope of delivery
• 1x smoke alarm device Dual Q
• 1x set of mounting hardware
• 1x assembly and operating instructions
Accessories
The following optional accessories can be
used:
• Relay module for smoke alarm
device Dual (item no. 2340 00)
• Radio module for smoke alarm device
Dual
(item no. 2347 00)
• KNX Module for smoke alarm device
Dual
(item no. 2343 00)
• Spacer sleeves (item no. 2342 00)
Device description
Selecting the installation location
When selecting the installation location for
the smoke alarm device, the specifications
of DIN 14676 apply. The most important
specifications are as follows:
• Attach as close as possible to the centre
of the ceiling (min. distance of 50 cm
from walls, lights and other obstructions)
• One smoke alarm device per room (max.
60 m2 area)
• Do not mount it in the direct proximity of
heat sources.
1 Mounting plate
2 Module interface
3 Smoke penetration openings
4 Function button
5 Ring indicator
6 Battery
7 230 V connection for power supply via
230 V base
1
45
2
7
6
3
Minimum protection/optimum protec-
tion
The following applies to flats and houses:
Minimum protection
• One smoke alarm device in every
bedroom, every child's room and in the
hallway/staircase (escape route).
• In the case of open connections across
two levels, a smoke alarm device is to be
mounted at the highest level.
• In the case of buildings spanning several
floors, a smoke alarm device must be
mounted on each floor.
Optimum protection
• One smoke alarm device per room and
floor
• In the case of larger buildings, use
networked smoke alarm devices
• Use specialised alarm devices (e.g. heat
detectors) in sensitive areas such as
kitchens, garages etc.
Wiring smoke alarm devices
A maximum of 40 Dual Q smoke alarm
devices can be networked together using a
two-core cable (e.g. telephone cable J-
Y(St)Y 2 x 2 x 0.6 mm). This enables an
alarm to be triggered over all the smoke
alarm devices in a residential unit at the
same time.
The maximum cable length varies
depending on the cable type and cross-
section used (for 1.5 mm2 = maximum 400
m).
Network the smoke alarm devices with one
another as follows:
1. Remove the pre-perforated cut-out for
the cable inlet from the mounting plate
with a suitable tool.
2. Wire the two-lead cable to the 3-pole
terminal block.
3. Push the terminal block onto the guide
rail of the bracket (will audibly engage).
System description of smoke alarm
devices
More detailed information with regard to ins-
tallation as per 1DIN 4676 can be found in
the "System description of smoke alarm devi-
ces", which is available in the Gira download
area (www.gira/download).
Inadmissible installation locations
The Dual Q smoke alarm device is suitanot -
ble for installation in caravans, campers,
boats etc.
Deceptive alarms
Some sites are unsuitable for the
installation of a smoke alarm device as
deceptive alarms are repeatedly triggered
due to local conditions (e.g. welding/
soldering work, very heavy water/cooking
vapour and similar fumes).
More detailed information with regard to
unsuitable installation sites can be found in
the "System description of smoke alarm
devices".
Deactivating smoke detection
Optionally, smoke detection of the smoke
alarm device can be deactivated. This
enables the smoke alarm device to also be
used in rooms which are unsuitable for
conventional smoke alarm devices. In this
case, the smoke alarm device only operates
as a heat detector and triggers an alarm
• As soon as the speed at which the
ambient air is heating up lies outside
normal parameters.
• If the ambient temperature is over
+54 °C.
Smoke detection can be deactivated as
follows:
1. Break out the DIP switch cover plate
with a suitable tool.
2. Set the DIP switches to the "ON"
position. Smoke detection is now
deactivated, and only heat detection is
active.
Installing the smoke alarm device
1. Install the mounting plate. For "surface-
mounted installation" of the networking
cable, use the spacer sleeves.
Optional: Before installation, you can
activate theft protection of the smoke alarm
device to impede unauthorised removal of
or tampering with the smoke alarm device.
For this purpose, cut out the pre-perforated
cut-out on the housing of the smoke alarm
device with a suitable tool. The lock can
only be opened with a tool when in the
locked state.
Networking terminal
An external button (e.g. emergency switch)
can also be connected in parallel via the net-
working terminal.
Termination of CE conformity
The CE conformity of the smoke alarm device
as per EN 14604 is terminated if the DIP
switch cover plate is broken out.
Click
N
N
N
NN N
N
N
NN
2. Lock the smoke alarm device on the
mounting plate (set in place and turn
clockwise).
Removal is carried out in the reverse
order (turn anti-clockwise and pull off).
3. Wait for the initialisation phase (approx.
30 s) and then carry out the function test
(see "Function test").
Activation/deactivation
The smoke alarm device features an internal
activation button (grey).
When locking the smoke alarm device into
the mounting plate/230 V base, the smoke
alarm device is activated automatically.
Alternatively, the activation button for the
function test can also be held manually (the
power supply of the smoke alarm device is
activated automatically. Initialisation phase
30 s).
The smoke alarm device is deactivated
automatically when the lock is disengaged.
Information and
recommendations for the expert
Declaration of performance
The Declaration of performance according
to Directive (EC) No. 765/2008, Directive
(EU) No. 305/2011 (Construction Products'
Regulations - CPR) and the Construction
Product Act CPA can be found either in the
download area (gira.de/Konformitaet) or
directly via the online catalogue at the
product (katalog.gira.de).
Briefing and transfer
Maintenance book for smoke
alarm devices
Gira offers the "Maintenance book for smoke
alarm devices" in the download area.
All the important data of the initial installa-
tion of the smoke alarm device should be
entered here.
Briefing and transfer of the
Instructions
Explain all the functions of the product to
the end user or their representative.
These instructions are part of the product
and must be transferred to the end user or
their representative for safekeeping.
Technical data
Type of alarm: Optical smoke alarm
and heat detector
Area of application: Inside (ceiling)
Installation in
recreational vehicles,
motor homes, etc: Not suitable!
Power
supply: via the smoke alarm
device battery
(encapsulated, not
replaceable)
In addition, AC 230
V when using item
no. 2331 02
Battery life: up to 10 years (after
activation)
Acoustic signal: Alarm: at least 85 dB
(A)
Test: approx. 75 dB
(A)
Optical indication: Ring indicator (red
LED) indicates
status and faults
Networking: Wired, with modules
Integrated interface:
For KNX module,
wireless module and
relay module
Function key for: Function test
Muting
Alarm
acknowledgement
Delaying "fault"
display
Ambient
temperature: -5 °C to +55 °C
Storage
temperature:
-20 °C to +65 °C
Transport
temperature:
-20 °C to +65 °C
Installation height: Max. 6 m
Protection type: IP 42
Housing dimensions: 125 x 48 mm (dia. x
h)
Weight: approx. 250 g
Standards: DIN EN 14604
RoHS/WEEE-
compliant: Yes
Environmentally
compliant disposal: Governed by EAR
6LE000969 D/A 34/22
Dual Q smoke alarm
device
2346 02
Assembly and operating instructions
en
Function button
The smoke alarm device Dual Q features an
easy-access main function button.
The following actions can be initiated using
the function button (grey) in normal
operation:
• Alarm acknowledgement
• Function test
• Muting
• Delaying fault/soiling display
Function test
The function test should be conducted:
• After the initial installation
• After every alarm, maintenance session
and fault message
Perform the function test
Carry out the function test as follows:
1. Press and hold the function button for
approx. 4 s. Initially, a brief
acknowledgement tone can be heard. A
muffled signal tone is then emitted, and
the ring indicator flashes.
2. Release the function button.
3. If the function test was successful: Press
and hold the function button until the
signal tone is muted and the ring
indicator goes out.
Muffled signal tone
The signal tone of the function test is
muffled (approx. 75 dB (A)). This is
intended to prevent hearing loss (e.g.
tinnitus).
Function test failure
Replace the smoke alarm device immediately
if it fails the function test two times in a row.
Non-operational smoke alarm devices may
not be installed.
Function test for wire-networked
smoke alarm devices
When a function test is carried out on wire-
networked smoke alarm devices, all the con-
nected smoke alarm devices emit only an
acoustic alarm. If this is not the case, check
the connections and networking lines.
Smoke alarm devices save lives
Observe the following when using smoke
alarm devices:
• Use only smoke alarm devices which
are compliant with DIN 14604
• Never cover smoke alarm devices
continuously or block them with objects
• Never install smoke alarm devices if
they are defective or not fully
operational
Operating and alarm signals
Local smoke alarm device
* Replace alarm device within 30 days.
Networked smoke alarm device
In the case of wired networking, signalling
occurs at the triggering smoke alarm device
as described above. The networked smoke
alarm devices signal as follows:
* Replace alarm device within 30 days.
Acknowledging alarm/deceptive
alarm
If the smoke alarm device has triggered an
alarm and a deceptive alarm has been
identified as the culprit, you can
acknowledge the alarm message by
pressing the function button. Then ensure
that the cause of the deceptive alarm has
been eliminated. Should this be temporarily
impossible, activate muting if necessary.
Signal tone R
R
R
RRin
in
in
ining
g
g
gg
i
i
i
iin
n
n
nnd
d
d
ddic
ic
ic
icica
a
a
aato
to
to
totor
r
r
rr Me
Me
Me
MeMea
a
a
aan
n
n
nnin
in
in
ining
g
g
gg
- - Operating
mode
Loud interval
tone
flashes
quickly
Local smoke
alarm
Loud
pulsating
signal tone
flashes
quickly
Local heat
alarm
8 brief signal
tones in 60 s
cycle
Flashes 8
times in 8 s
cycle
Fault
2 brief signal
tones in 60 s
cycle
Flashes
once in 5 s
cycle
Weak battery*
1 s-long
signal tone in
2 s cycle
Lights up
continuousl
y
Function test
(alarm device
has triggered
alarm)
1 s-long
signal tone in
2 s cycle
flashes
quickly
Function test
(alarm device
has not
triggered
alarm)
-
Flashes in
2 s cycle
Muting
Brief signal
tone in 1 s
cycle
Flashes in
1 s cycle EMC fault
Brief signal
tone in 250
ms cycle
Flashes for
5 min in 250
ms cycle
Identification
of alarm device
Signal tone Ri
Ri
Ri
RiRing
ng
ng
ngng
i
i
i
iind
nd
nd
ndndi
i
i
iic
c
c
cca
a
a
aat
t
t
tto
o
o
oor
r
r
rr Me
Me
Me
MeMea
a
a
aan
n
n
nnin
in
in
ining
g
g
gg
Loud
interval
tone
-
Smoke or heat
alarm message
1 s-long
signal tone
in 2 s cycle
-
Function test
(remote starting)
2 brief
signal tones
in 60 s cycle
-
Weak battery*
Signalling when using the 230 V
base
When using the 230 V socket, the
signalling differs.
Please observe the installation and
operating instructions for the 230 V base
for Dual Q smoke alarm devices.
Activating muting
The smoke alarm device features so-called
"muting".
It deactivates smoke alarm device operation
for a maximum of 15 min. This makes sense
• As a measure to prevent deceptive
alarms, e.g. while engaged in activities
which create a large amount of dust
(sweeping a dusty room, sweeping the
chimney etc.) or
• to stop an alarm triggered by the
detection of harmless smoke (e.g. when
searing meat)
Activate muting as follows:
1. Press the function button for 1 s until
the acknowledgement tone is heard.
2. Release the function button: The ring
indicator flashes in a 2 s cycle, and
muting is activated.
After 15 minutes, muting is automatically
deactivated and the smoke alarm device is
back in the normal operating mode.
Delay fault/soiling indication
The photocell integrated in the smoke alarm
device delays the "Smoke alarm device
soiled" warning up to 12 hours in darkness.
This does not affect the functionality of the
smoke alarm device!
The message can be delayed by 8 hours at a
time for a maximum of 7 days if the initial
signalling occurs at an unfavourable point in
time.
For this purpose, push the function button
until the first signal tone to sound is muted.
The "Fault/soiling" message is now
signalled after a delay.
Care and maintenance
Clean and maintain the smoke alarm device
on a regular basis to ensure full operability.
Care
Wipe the smoke alarm device with a moist
(not wet!) cloth on a regular basis.
The smoke alarm device can also be cleaned
of dust carefully with a vacuum cleaner
(lowest setting).
Maintenance
Maintenance and duty to maintain
As per DIN 14676, you are required to have
smoke alarm devices maintained annually
by a qualified expert.
The results of maintenance should be
entered in the maintenance book for
smoke alarm devices.
Observe the following: If this required
maintenance is not carried out, insurance
coverage may be nullified in case of fire.
Renovation work
Disposal
Dispose of the smoke alarm device by the
date indicated on the device's label or when
the battery is flat.
Troubleshooting
Renovation work
If possible, do not install the smoke alarm
device until all renovation work has been
completed. Should this not be possible,
cover the smoke alarm device with the
included covering cap (remove it again
once the work is complete!). Alternatively,
you can remove the smoke alarm device
for the duration of the work. Once the work
is complete, the original functional
readiness of the installed smoke alarm
device must be restored and tested
(function test).
Danger
There is a risk of explosion if the
battery is removed by force!
The battery of the smoke alarm device
cannot be replaced.
If the battery is forcibly removed from the
device, it may explode if damaged.
The smoke alarm device must always be
disposed of completely.
Battery life
The battery life (approx. 10 years after
activation) can be reduced by the following
factors:
• The additional use of modules.
• Networking of the smoke alarm devices
via networking terminal.
• More test alarms than prescribed.
The Gira smoke alarm device is
an electric and electronic device
in the sense of EU guideline
2002/96/EC.
The device was developed and
manufactured using high-quality
materials and components.
These materials and components
can be reused and recycled.
Please consult the regulations
governing the separate collec-
tion of electric/electronic waste
applicable for your country.
These devices may not be dispo-
sed of with household waste.
The correct disposal of waste
equipment can prevent possible
negative effects upon humans
and the environment.
Problem Solution
No signal can be
heard during the
function test
Check locking of the
smoke alarm device
Frequent
deceptive alarms
Check installation site
for interference
sources
Cleaning smoke alarm
device
Warranty
The warranty is provided in accordance with
the statutory requirements via the retailer.
Please hand over or send faulty devices
postage paid and with a description of the
problem to your sales representative
(retailer / installation company / electronics
retailer),
They will forward the devices to the Gira
Service Centre.
Information and
recommendations for occupants
Response in case of fire
To facilitate a proper response by the
persons concerned in case of fire,
DIN 14676 recommends putting up
information in every unit on how to respond
in case of fire. This information should be
provided in the languages which are
commonly used, You may also need to take
the end users of a residential unit into
consideration (e.g. non-German speakers).
The standard also strongly recommends
calling in a responsible fire prevention
authority in advance. This authority can
define divergent or different
recommendations or assessments.
More detailed information on this can be
found in the "System description of smoke
alarm devices" or in DIN EN 14676.
The following always applies:
• Always protect yourself first!
• Warn other occupants.
• Leave the room/building immediately.
• Help people in need while escaping.
• In case of thick smoke, keep low to the
ground.
• Check whether all persons have left the
room/building.
• Should you not be able to leave the room/
building, close all doors and seal all gaps
and other narrow openings, e.g. with wet
towels. Alert people to your presence
from the window.
• Do not call the fire brigade until you are
safe.
• Only fight the fire yourself if you will not
be putting yourself in danger.
Q label and warranty
The Q label has no effect on the legal
warranty.
Warning function of the
smoke alarm device
The sole purpose of the warning function
of a smoke alarm device is to warn the
people present in a unit (e.g. flat) or
building in a timely manner. The people
present organise their rescue themselves
and are responsible for notifying the
station providing assistance (e.g. fire
brigade).
Smoke alarm devices do not extinguish
fires!
Gira
Gira
Giersiepen GmbH & Co KG
Elektro-Installations-Systeme
P.O. Box 1220
42461 Radevormwald, Germany
Phone: +49 2195 602 - 0
Fax: +49 2195 602 - 191
info@gira.de
www.gira.de


Product specificaties

Merk: Gira
Categorie: Rookmelder
Model: Basic Q

Heb je hulp nodig?

Als je hulp nodig hebt met Gira Basic Q stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Rookmelder Gira

Handleiding Rookmelder

Nieuwste handleidingen voor Rookmelder