Genelec 8040 BPM Handleiding

Genelec Speaker 8040 BPM

Lees hieronder de 📖 handleiding in het Nederlandse voor Genelec 8040 BPM (47 pagina's) in de categorie Speaker. Deze handleiding was nuttig voor 21 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/47
8040B
8050B
Operating Manual 2-6
Käyttöohje 7-11
2
System
The GENELEC 8040B and 8050B are
two way active monitoring loudspeakers
designed to produce high SPL output, low
coloration and broad bandwidth in a small
enclosure size. They are suitable for a wide
variety of tasks, such as near eld monitor-
ing, mobile vans, broadcast and TV control
rooms, surround sound systems and home
studios. Designed as active loudspeak-
ers, they contain drivers, power ampliers,
active crossover lters and protection cir-
cuitry. The Minimum Diraction Enclosure™
(MDE™) and advanced Directivity Control
Waveguide™ (DCW™) technologies provide
excellent frequency balance even in dicult
acoustic environments.
Drivers
The bass driver dimensions are 165 mm (6
1/2”) and 205 mm (8”) for 8040B and 8050B
respectively. The long, ow optimized reex
tube has a large cross sectional area and
terminates with a wide are at the back of
the enclosure. The high frequency driver is a
19 mm (3/4”) metal dome on the 8040B and
a 25 mm (1”) metal dome on the 8050B. Both
drivers are magnetically shielded.
Crossover
The active crossover network consists of two
parallel bandpass lters. The crossover fre-
quency is 3.0 kHz on the 8040B and 1.8 kHz
on the 8050B. The active crossover controls
(“treble tilt”, desktop low frequency”, “bass
tilt” and “bass roll-o”) allow precise match-
ing of the loudspeakers to any room environ-
ment.
Amplifiers
The amplier unit is mounted in the rear of the
loudspeaker enclosure. The unit incorporates
special circuitry for driver thermal overload
protection. Variable input sensitivity allows
accurate level matching to console output
section.
Connections
Each loudspeaker is supplied with a mains
cable and an operating manual. Before con-
necting up, ensure that the mains switch is
o (see gure 1). Audio input is via a 10 kOhm
balanced XLR connector, but unbalanced
leads may be used as long as pin 3 is
grounded to pin 1 of the XLR (see gure 3).
Once the connections have been made, the
loudspeakers are ready to be switched on.
Mounting considerations
Align the loudspeakers correctly
Always place the loudspeakers so that
their acoustic axes (see gure 2) are aimed
towards the listening position. Vertical place-
ment is preferable, as it minimises acoustical
cancellation problems around the crossover
frequency.
Maintain symmetry
Check that the loudspeakers are placed
symmetrically and at an equal distance from
the listening position. If possible, place the
system so that the listening position is on the
centerline of the room and the loudspeakers
are placed at an equal distance from the cen-
terline.
Minimise reflections
Acoustic reections from objects close to the
loudspeakers like desks, cabinets, computer
monitors etc. can cause unwanted colouration
and blurring of the sound image. These can
be minimised by placing the loudspeaker clear
of reective surfaces. For instance, putting the
loudspeakers on stands behind and above the
mixing console usually gives a better result
than placing them on the meter bridge.
Genelec 8040B and 8050B Active Monitoring Systems
3
Minimum clearances
Sucient cooling for the amplier and func-
tioning of the reex port must be ensured if
the loudspeaker is installed in a restricted
space such as a cabinet, or integrated into
a wall structure. The surroundings of the
loudspeaker must always be open to the
listening room with a minimum clearance of
5 centimeters (2”) behind, above and on both
sides of the loudspeaker. The space adjacent
to the amplier must either be ventilated or
suciently large to dissipate heat so that the
ambient temperature does not rise above
35 degrees Celsius (95°F).
Mounting options
The vibration insulating Isolation Positioner/
Decoupler(Iso-Pod™) table stand allows
tilting of the loudspeaker for correct align-
ment of the acoustic axis. The stand can be
attached to three mounting points allowing
vertical and symmetrical horizontal position-
ing (see gures 1 and 5).
Genelec 8040B and 8050B can be tted
to Omnimount® Series 30 (8040B) and 60
(8050B) and König & Meyer loudspeaker
mounts on two sets of M6x10 mm threaded
holes on the back of the enclosure. On the
base of the enclosure is an M10x10 mm
threaded hole which can be used for secur-
ing the loudspeaker to its base. Do not use
this thread for mounting the loudspeaker on
a microphone stand which has a 3/8” UNC
thread.
Setting the input sensitivity
The input sensitivity of the loudspeakers
can be matched to the output of the mixing
console, or other source, by adjusting the
input sensitivity control on the rear panel
(see gure 1). A screwdriver is needed for
the adjustment. The manufacturers default
setting for this control is -6 dBu (fully clock-
wise) which gives an SPL of 100 dB @1m with
-6 dBu input level.
ISSTM autostart function
When the power switch on the loudspeaker
is set to “ON”, the Intelligent Signal Sens-
ingTM (ISSTM) autostart function of the loud-
speaker is active. Automatic powering down
to standby mode happens after a certain time
when playback has ended. The power con-
sumption in standby mode is typically less
than 0.5 watts. The playback will automati-
cally resume once an input signal is detected
from the source.
There is a slight delay in the automatic
powering up. If this is undesirable, the ISS
TM
function can be disabled by setting the “ISS
DISABLE” switch on the back panel to “ON”
position. In this mode, the monitor is pow-
ered on and o using the power switch on
the back panel.
Setting the tone controls
The frequency response of the system may
also have to be adjusted to match the acous-
tic environment. The adjustment is carried
out by setting the three tone control switch
groups “treble tilt”, “bass tilt” and “bass roll-
o” on the rear panel of the amplier. There is
also a special “desktop low frequency” tone
control which gives an attenuation of 4 dB at
160 Hz to compensate the eect of a mixing
console, desk or other reflective surface
between the listener and the loudspeaker.
The factory settings for these controls are all
“OFF” to give a at anechoic response.
Bass roll-off control
Bass roll-o (rst switch group from the left)
aects the low frequency roll-o of the loud-
speaker and attenuates its energy output
near the cut-o frequency. Attenuation levels
of -2, -4 or -6 dB can be selected.
Figure 1. Amplifier panel layout of the 8040B
Figure 2. Location of the acoustic axis
Figure 3. RCA to XLR cable
Cable
Screen
RCA
(Source)
XLR
(Speaker)
DESKTOP
CONTROL
20Hz 160Hz
BASS
ROLL-OFF
800Hz
+2
0
-4
-6
-2
dB
BASS
TILT
OFFON
4 kH z 2 0kH z
ALLOFF
TREBLE
TILT
dBu
-4
-6
0-2
8040B BI-AMPLIFIED
MONITORING SYSTEM
MAGNET ICALLY SH IELDED
MADE IN FINLAND
MAINS INPUT
50 / 6 0 H z 110 W 230 V~
SERIAL NUMBER
292-8040T-6
www.genel ec.com
+ GND-
1
3
2
292-8040W
WARN IN G
ELECTRIC SH OCKHA ZARD ONOTOPE N ONOTSUBJ EC. D . D T T O WATEROR
PERSONNEL. USE EA RTHED MA INS CONNECTION ONL NOTE! TH IS MONI RY. TO
MOISTURE . NO USER SERV ICEA BLE NSIDEPARTSI . RE FERSERVICI NG T O QUALIFI ED
SHOULD NOT BE MOUNTED ON A MICROPH ON NDAS TH ASE S TA E B E THREA D IS M1 0.
ÊTRE RACCORDÉ À LAT ERRE.NOTE EMONITE UR NE DOI! C TP ASÊTRE MONTÉ
AVERTISS EM EN T
SUR U N PIE D DE MICROPH ON ARLEE C PAS D E VIS EST DE TYPE M1 0.
ADRESSER TOUTE RÉ PARATION À U N PERSONNELQUALIFI É ETAP REI LDOIT. C PA
RISQUE DE CH OCÉ LECTRIQU E. NE S OU VRIR. NE S EX POSEPA PA R À L'EAU OU
L'HUMI DITÉ. AUCU N COMPOSAN L'INTÉRIE U E MPLAÇABLE 'UTI LISATEU R.T À R R PAR L
LAITE ON LIITETTÄV Ä SUOJAMA ADOITUSKOSKETTIMI LLA RU STETTUUNVA
PISTORASIAA N. APPA RATETMÅ TILKOPLES J ORDET STIKKONTAKT.
APP AR EN SKALL ANSLU STI LL JORDA TTAG.AT TA T U
BASS
ROLL-OFF
DESKTOP
CONTROL
TREBLE TILTBASS TILT
+4
+2
+6
IN PUT SEN SITIVITY
REQUIRED F OR
100dBSPL@1m
ISS
DISABLE
REFLEX PORT
TONE CONTROLS
Iso-Pod™ TABLE
STAND
THREADS FOR
CEILING AND
WALL MOUNTS
CONNECTOR PANEL
(HORIZONTAL)
ACOUSTIC
AXIS
> 0,7 m
h
8040B: h=240 mm
8050B: h=290 mm


Product specificaties

Merk: Genelec
Categorie: Speaker
Model: 8040 BPM

Heb je hulp nodig?

Als je hulp nodig hebt met Genelec 8040 BPM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Speaker Genelec

Handleiding Speaker

Nieuwste handleidingen voor Speaker