Gemini 7024 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Gemini 7024 (8 pagina's) in de categorie Auto alarm. Deze handleiding was nuttig voor 63 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
GEMINI 7024
7024
7024.1
7024US
7024.1US
Car
...................................
...........................................................
INSTALLATION CERTIFICATE
The undersigned,qualified installer,attests to have personally fitted the here described Vehicule
Security Following the manufacturer instructions.
Signature ................................................................................
Type of product :
By :
Sold on :
by GEMINI TRADING S.r.l. Via Luigi Galvani 12 21020 Bodio Lomnago (VA) Italy
Tel. +39 0332 943211 - Fax +39 0332 948080
E-mail : info@gemini-alarm.com
DESCRIPTION DESCRIPTION
Gemini 7024US is a modular alarm unit with ultrasonic sensors; studied to be
installed on vehicles equipped with original central door locking control.
Gemini 7024 is a modular alarm without ultrasonic sensor.
The systems Gemini 7024US and Gemini 7024 can be installed on vehicles (with
diesel or petrol engine) with a 12V battery with negative to earth.
Gemini 7024US.1 like 7024US without electronic keys.
Gemini 7024.1 like 7024 without electronic keys.
FUNCTIONS FUNCTIONS
- Outlet for direction indicator lights - Blinker
- Volumetric and Perimetric protection (only for US models).
- Positive and negative control for vehicles equipped with Pack-comfort system.
- Engine immobilisation.
- Negative control for external supplementary siren.
- Automatic arming and "GARAGE " position function (only for US models).
- Emergency disarming through electronic key (only for 7024 and 7024US).
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS
- Position the system wiring harness away from high voltage wires in order to avoid interference that may cause
damages to the system.
- On vehicles with a catalytic converter the engine immobilisation must be carried out on the fuel pump.
- If the system is supplied with volumetric sensors (art. 7024US), the transducers must be positioned at the top
of each windscreen pillar and away from the facia outlet.
- Connect the positive feeding of the alarm system to the battery positive terminal and the negative feeding of
the alarm system to the battery negative terminal or to the vehicle frame.
- IMPORTANT: to obtain a correct working of the automatic arming and the perimetrical protection
functions, it is COMPULSORY to connect the GREEN-BROWN wire to the door/boot switches.
- The unit memorises the polarity of the arming and disarming controls from the vehicle 10 seconds
after the alarm feeding. The LED lights fix.
During this period it is possible to carry out only the “Blinker” exclusion.
CONNECTION TO THE RADIO RECEIVER
For vehicles with original positive control receiver, follow the fitting diagram A.
For vehicles with original negative control receiver, follow the fitting diagram B.
For vehicles with codified receiver with single control button, negative to rest, follow the fitting diagram C.
For vehicles with codified receiver with a double control button, negative to rest, follow the fitting diagram
D.
For vehicles with codified receiver with button or control button free to rest, follow the fitting diagram E.
For vehicles with codified receiver and central door locking closure control supplied with alarm connection,
follow the fitting diagram F.
NOTE: FOR THE DIAGRAMS OF THE VEHICLES ASK TO THE CAR DISTRIBUTOR OF THE AREA.
ULTRASONIC SENSOR ADJUSTMENT( only for 7024US)
The ultrasonic sensor adjustment is carried out while alarm armed with the sensor exclusion
function activated.
- Put the electronic key in the socket, the LED flashes for one second.
- Arm the alarm system with the vehicle original transmitter. The arming is signalled by 2
pulses of the direction indicator lights. Wait the end of the inhibit time.
- Put one hand in the vehicle and move it. The sensor detects the movement without triggering
the alarm; the LED switches on. If the LED does not switch on increase the sensitivity (fully
clockwise) and repeat test.
WIRING CONNECTIONS
(DISCONNECT THE NEGATIVE BATTERY TERMINAL AND RE-CONNECT AFTER THE INSTALLATION IS COMPLETE).
FUNCTIONS WIRES COLOUR
Earth ðð
BROWN
Battery positive ðð
RED
Engine immobilisation (Max 8A) ðð
2 x GREY
Ignition live ðð
YELLOW
Direction indicator lights ðð
2 x ORANGE
Door pin switches ðð
GREEN-BROWN
Boot pin switch ðð
GREEN
Sensors inlet ðð
GREEN-BLACK
Positive alarm armed ðð
PINK
Self-powered siren control ðð
BLUE
Sel. alternative or continuous sound ðð
BLACK (10cm.)
Additional siren/horn control ðð
YELLOW-BLACK
Negative comfort control ðð
WHITE-BLACK
Positive comfort control ðð
RED-BLACK
Selection for automatic activation ðð
YELLOW-GREEN (10 cm.)
Arming/disarming control
Refer to diagrams A, B, C, D, E, F.
ðð
YELLOW-RED, BROWN-RED,
YELLOW-BLUE WHITE-L. BLUE,
GREEN-BLUE.
NOTE: connect the 2- pin connectors of the wiring harness to the electronic key socket connectors
(only for US models). WORKING DESCRIPTION WORKING DESCRIPTION
- ALARM ARMING WITH THE ORIGINAL TRANSMITTER : press on the original transmitter button while
closing the doors of the vehicle. The arming is signalled by one pulse of the direction
indicator lights if the visualisation is not excluded.
- ALARM ARMING WITH THE EXCLUSION OF THE ULTRASONIC AND EXTERNAL SENSORS (US MODELS):
put the electronic key in the appropriate socket before arming the alarm system. The arming
is signalled by 2 pulses of the direction indicator lights if the visualisation is not excluded.
Note: the sensor exclusion is obtained also with the function of automatic arming activated.
- ALARM DISARMING: press on the transmitter’s button at the same time of the vehicle’s door
opening. The disarming is signalled by 3 pulses of the direction indicator lights; 5 pulses if an
alarm condition has occurred (if the visualisation function is not excluded).
- ALARM DISARMING THROUGH THE ELECTRONIC KEY (ONLY FOR 7024 AND 7024US): to obtain this
function put the electronic key in the appropriate socket. The disarming is signalled by 3
pulses; 5 pulses if an alarm condition has occurred (if the visualisation function is not
excluded).
SPECIAL FUNCTIONSSPECIAL FUNCTIONS
ALARM AUTOMATIC ARMING.
To obtain this function, connect the YELLOW-GREEN wire to earth. The alarm will
automatically arm 30 sec, after the engine switching OFF and the door opening.
SELF-LEARNING OF AN ELECTRONIC KEY CODE (US MODELS)
Close the vehicle’s doors and disarm the alarm system. Turn the ignition key to ON and within
10 seconds put the electronic key to learn in the socket. The LED switches on for one second.
It is possible to learn a maximum number of 3 keys.
Note: if you put a learned key in the socket this will not annul the other memorised keys;
otherwise, if you put a new key in the socket the first memorised key will be annulled.
GARAGE POSITION (ONLY US MODELS).
With this function it is possible to leave the vehicle in the servicing or in the washing centres without
leaving the original transmitter or the electronic key to the staff. To obtain this function, connect the
yellow-green wire to earth.
ACTIVATION OF THE GARAGE POSITION.
1. Disarm the alarm, turn the ignition key to ON and open one door.
2. Turn the ignition key to ON and within 15 sec. put the electronic key in the socket. 2
pulses of the LED signal the activation of the function.
Note: put the key in the socket within the 15 seconds otherwise the procedure will
automatically annul.
3. Turn the ignition key to OFF position.
In this condition the engine of the vehicle can be switched on for 20 times without triggering
the alarm. The working of the GARAGE position is signalled through the fast flashing of the
LED if the ignition key is in ON position for more than 10 seconds.
BLINKER EXCLUSION WHILE ALARM ARMING/DISARMING
This function is necessary on vehicles with original flashing of the direction indicator lights
while opening and closing the door.
BLINKER EXCLUSION ACTIVATION.
Before supplying the alarm unit, turn the ignition key to ON position.
Supply the alarm system and turn the ignition key to OFF.
LED’S MEMORY
While alarm disarmed it is possible to verify if an alarm condition has occurred and to
determine the cause following the LED flashing.
LED signalling Alarm triggering
¬l¬ Internal sensors (only 7024US)
¬¬l¬¬ Doors pin switches
¬¬¬l¬¬¬ Ignition live
¬¬¬¬l¬¬¬¬ External sensors(Green-Black wire)
l LED OFF (2 sec.) ¬ LED ON (1 sec.)
The inhibit time is 30 sec. for each alarm triggering. Turn the ignition key to ON to stop the
LED flashing.
TECHNICAL DATA
Power supply 10,5 ÷14,5VDC
Max. current absorption 5 mA
Working temperature -30° + 85°
Contact capacity horn control 8A to 20° C
Contact capacity visualising signals 8A to 20° C
Contact capacity engine immobilisation 8A to 20° C
Alarm period 30 sec.
Max. current positive alarm armed (+A) 1A
Max. current comfort control 100mA
Max. number codifying keys 3 (only US models)
SELF-POWERED CODIFIED 7125TNC SIREN (US models)
DESCRIPTION
The self-powered codified siren is an audible signalling device with high power designed to be installed in
the engine compartment of the vehicles, which can be connected to the alarm unit through the wiring
harness supplied with the kit.
Wiring connections (for the installer) :
disconnect the negative of the battery and only re-connect after the installation is complete.
Wires Function
BLACK initialled RB ê Battery positive
BLACK initialled MB ê Battery negative
BLACK initialled S ê Gemini alarm PINK wire
BLACK initialled L ê Gemini alarm BLUE wire
Connect one end of the BLACK initialled V wire to the bonnet button and the other end to the alarm unit
GREEN wire.
WORKING
The electronic siren 7125TNC is supplied with a self-powering internal device that allows the working of the
siren also in absence of the power or if the connection wires to the unit are cut.
Through the codified system between alarm and siren, the alarm activates and de-activates both the
battery charging and the power of the siren.
The battery recharges only with alarm disarmed. The self-power activates only with alarm armed and 3
minutes after the alarm disarming. Before de-activating the siren it is necessary to wait 4 minutes after the
alarm disarming.
MOUNTING
Mount the siren in the engine compartment of the vehicle using the screws and the bracket supplied with
the kit and a 8 mm adjustable wrench to tighten the nuts.
Mount the siren away from areas of intense heat and turn the acoustic ear trumpet to low.
Protects the wires from water and humidity isolating connection points with protective sheaths.
Technical data
Power supply 12 V
Current absorption alarm ON 3 mA
Current absorption alarm OFF 7 mA
Audible tone > 120 dB


Product specificaties

Merk: Gemini
Categorie: Auto alarm
Model: 7024

Heb je hulp nodig?

Als je hulp nodig hebt met Gemini 7024 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden