Safety advice
Assembly, connection and maintenance of the device may only be executed by personnel trained
accordingly. Use for the installation of the Rollotimer a deep switch box. Please pay attention that no
cables are affecting the proper latching of the device. To prevent overvoltage and therewith a
malfunction, plug or unplug the operation panel only in de-energized state! For this purpose
disconnect the power supply of the electric circuit by switching off the corresponding fuse.
Technical Data Ref. No. 941.DCZ2.00
Power supply 230V / 50Hz
Switching voltage 250 V AC
Switching contact load 3 A (cos phi=1)
Ambient temperature +5°C to +45°C
Running time 2,5 minutes (max.)
Changeover delay min. 0,5 seconds
Accuracy < 5 seconds /day
Power reserve approx. 0,5 minutes
Protection class IP 20
Safety class II
Conformity CE
Installation and
operation manual
ROLLOTIMER Standard
Ref. No. 941.DCZ2.00
M
PE green/yellow
N blue
L black/brown
blue
brown or black
blue
brown or black
brown or black
Connection diagram
N L N ZU AUF
N NL down up
X0469
Programming of ROLLOTIMER Standard
1. Enter programming mode Press â–² (UP) and â–¼ (DOWN) simultaneously
for approx. 3 seconds.
2. Time of day
programming
Setting of the hour
18 : 32
Use â–² (UP) to set the hour.
Press â–¼ (DOWN).
Setting of the minutes
3218 :
Use â–² (UP) to set the minutes.
Press â–¼ (DOWN).
3. Automatic
opening
programming
Setting of the hour
07 : 20
Use â–² (UP) to set the hour.
Press â–¼ (DOWN).
Setting of the minutes
2007 :
Use â–² (UP) to set the minutes.
Press â–¼ (DOWN).
4. Automatic
closing
programming
Setting of the hour
21 : 45
Use â–² (UP) to set the hour.
Press â–¼ (DOWN).
Setting of the minutes
4521 :
Use â–² (UP) to set the minutes.
Press â–¼ (DOWN).
5. Operation Mode
setting
Use â–² (UP) to set one of the following modes:
man = manual operation
auto = set automatic opening and closing time
var = a random generator changes the set
automatic opening and closing time by +/- 15
minutes
6. Exit
programming
mode
Press â–¼ (DOWN).
Note: setting of the values
The value which you want to set is selected by the DOWN button and is signaled by the flashing of
the value.The value itself is set with the UP button which is raised with every push.
The values are raised automatically by pressing permanently the button. If you have reached the
desired value, confirm it by pressing DOWN which will switch automatically to the next value for
programming.
The programming mode will be closed automatically, if there is no input for 30 seconds. All set values
until then are set and safed. Due to the premature closing of the programming mode, the operation
mode will be set to manual (man).
Operation of the Rollotimer
push â–¼ (DOWN) < 1 second Jog mode or STOP, if motor is running already
push â–¼ (DOWN) > 1 second DOWN command
push â–¼ (DOWN) > 6 seconds DOWN command +
time saved for DOWN command
push â–² (UP) < 1 second Jog mode or STOP, if motor is running already
push â–² (UP) > 1 second UP command
push â–² (UP) > 6 seconds UP command +
time saved for UP command
pushâ–¼ (DOWN) + â–² (UP) < 1 second
simultaneously
Change of operation mode
push â–¼ (DOWN) + â–² (UP) > 1 second and < 3
seconds simultaneously
Activation of programming mode
push â–¼ (DOWN) + â–² (UP) > 6 seconds
simultaneously
General reset
(restore factory settings)
Jog mode
To adjust the angle of the venetian blinds push the UP or DOWN button (up to 1 second). The
automatic mode (auto) remains unchanged.
Quick programming
If the UP or DOWN button is pressed longer than 6 seconds, the blind is running in the direction and
the current time will be saved as the automatic UP or DOWN command time (memory function).
Operation modes
Manual mode man
Automatic mode (day programm) auto
Vacation mode: automatic + random generator var
You can enable the by pushing the UP and DOWN buttons simultaneously. Bymanual mode (man)
repeating this, it will be switched back to the original mode (auto or var)
The activation of the will open and close the blinds according to theautomatic mode (auto)
programmed times.
The activation of the will open and close the blinds according to thevacation mode (var)
programmed times with a randomly generated shift of +/- 15 minutes.
The blinds can be open and closed manually in any operation mode by pushing â–² (UP)
or â–¼ (DOWN).
Factory settings
Day programm UP 07:00h, DOWN 21:00h
Time 00:00h
Mode Man


Product specificaties

Merk: Geba Tronic
Categorie: Garagepoortopener
Model: ROLLOTIMER Standard

Heb je hulp nodig?

Als je hulp nodig hebt met Geba Tronic ROLLOTIMER Standard stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Garagepoortopener Geba Tronic

Handleiding Garagepoortopener

Nieuwste handleidingen voor Garagepoortopener