GE ZV750SY Handleiding

GE Afzuigkap ZV750SY

Lees hieronder de đź“– handleiding in het Nederlandse voor GE ZV750SY (12 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 51 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
GE Monogram®
Installation
Instructions
36" Vent Hood
Model
ZV750
Before you begin—Read these instructions completely and carefully.
IMPORTANT: Save these instructions for local inspector’s use.
IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.
NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer.
NOTE TO CONSUMER: Keep these instructions with your Owner’s Manual for
future reference.
This appliance must be properly grounded. See “Electrical Supply”, page 4.
WARNING
2
If you have questions concerning the
installation of this product, call the GE Answer
Center® Consumer Information Service at
800.626.2000, 24 hours a day, 7 days a week.
If you received a damaged vent hood, you
should contact your dealer.
CAUTION!
Due to the weight and size of these vent hoods
and to reduce the risk of personal injury or
damage to the product, TWO PEOPLE ARE
REQUIRED FOR PROPER INSTALLATION.
WARNING!
To reduce the risk of fire or electric shock,
do not use this range hood with any external
solid-state speed control device. Any such
alteration from original factory wiring could
result in damage to the unit and/or create an
electrical safety hazard.
To reduce the risk of fire and to properly
exhaust air, be sure to duct air outdoors. Do
not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces or garages.
WARNING: TO REDUCE THE RISK OF FIRE,
USE ONLY METAL DUCTWORK.
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended
by the manufacturer. If you have any
questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch
power off at service panel and lock service
panel to prevent power from being switched
on accidentally. If the service panel cannot be
locked, fasten a tag or prominent warning
label to the panel.
For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards including
fire-rated construction.
Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to
prevent back drafting. Follow the heating
equipment manufacturer’s guidelines and
safety standards such as those published by the
National Fire Protection Association (NFPA),
and the American Society for Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
Contents Design Information
Model Available ...................................................................................................................................3
Optional Accessories ...........................................................................................................................3
Product Dimensions & Clearances .................................................................................................... 3
Advance Planning ............................................................................................................................... 4
Electrical Supply ..................................................................................................................................4
Installation Preparation
Duct Fittings ........................................................................................................................................ 5
Tools and Materials Required ............................................................................................................. 6
Step 1: Remove the Packaging ............................................................................................................ 6
Installation
Step 2: Check Installation Hardware ..................................................................................................7
Step 3: Ductwork, Wiring, Hood Attachment Locations .................................................................. 7
Step 4: Install Mounting Brackets.......................................................................................................8
Step 5: Install the Hood ......................................................................................................................8
Step 6: Install Duct Bracket.................................................................................................................9
Step 7: Connect Ductwork ................................................................................................................10
Step 8: Connect Electrical .................................................................................................................10
Step 9: Install Decorative Duct Cover and Utility Bars.................................................................... 10
Step 10: Install Filters ........................................................................................................................ 11
Step 11: Finalize Installation .............................................................................................................11
3
Design Information
36" Vent Hood
Model
ZV750
Model
Available
Optional
Accessories
This vent hood is designed to be used in
vented installations.
A decorative duct cover is provided to cover
the duct from the top of the hood to an 8 ft.
or 9 ft. ceiling.
The vent hood must be installed 24" min. and 30" max.
above the cooking surface. 25-1/2" is recommended to
insure that the duct cover meets the ceiling. The cooking
surface should be at least 36" above the floor. Installation
will be easier if the vent hood is installed before the range
or cooktop and countertop is installed.
Product
Dimensions
& Clearances
Model
ZX10SY
An optional stainless steel duct cover is
available for 9 ft. to 10 ft. ceiling installations.
(The supplied duct cover is sized to reach 8 ft.
to 9 ft. ceilings.) Order the optional duct
cover at the same time as the vent hood and
have on site before installation.
*26-1/4" for 8 ft. ceiling
38-1/4" for 9 ft. ceiling
38-1/4" to 50-1/4" for 9 ft. to
10 ft. ceiling using optional
accessory ZX10SY Duct Cover
*The distance between the cooking surface and the bottom
of the hood must be at least 24" and up to 30". The 25-1/2"
recommended installation height, above the standard 36"
countertop, will insure duct cover fit to the ceiling.
*25-1/2" Recommended
36" Min.
*Height
to Ceiling
8-1/4"
34-5/8"
21-5/8"
Recirculating Operation
This hood may be installed for
recirculating operation. One of the
following kits is required and must be
ordered with the hood.
ZXR758 – For up to 9 ft. ceiling height.
ZXR7510 – For up to 10 ft. ceiling height.
Both the hood and accessory must be on
site at the time of installation. Follow the
installation instructions packed with the
accessory to complete the installation.


Product specificaties

Merk: GE
Categorie: Afzuigkap
Model: ZV750SY

Heb je hulp nodig?

Als je hulp nodig hebt met GE ZV750SY stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap GE

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap