GE JN328KSA Handleiding

GE Afzuigkap JN328KSA

Lees hieronder de đź“– handleiding in het Nederlandse voor GE JN328KSA (32 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
Write the model and serial
numbers here:
Model # _________________
Serial # _________________
You can find them on a label on
the back wall of the hood.
ESPAĂ‘OL
Para consultar una version en
español de este manual de
instrucciones, visite nuestro sitio de
internet GEAppliances.com.
RANGE HOODS
49-80589-7 01-17 GEA
SAFETY INFORMATION . . . . . . . . . . . 2
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . 4
ASSISTANCE / ACCESSORIES . . . 22
USING THE HOOD
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CARE AND CLEANING
Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
INSTALLATION INSTRUCTIONS . . 8
TROUBLESHOOTING TIPS . . . . . . . . 16
JV247*– Vent & Recirculation options
JV248*– Vent & Recirculation options
JN327–Recirculation only
JN328–Recirculation only
JV338*–Vent options only
JV347*– Vent & Recirculation options
JV348*– Vent & Recirculation options
JV367*– Vent & Recirculation options
RN328–Recirculation only
AV447*– Vent & Recirculation options
OWNER’S MANUAL &
INSTALLATION
INSTRUCTIONS
GE is a trademark of the General Electric Company. Manufactured under trademark license.
249-80589-7
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
SAFETY INFORMATION
SAFETY PRECAUTIONS
WARNING TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power
off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
C. Do not use this unit with any solid-state speed
control device.
D. This unit must be grounded.
CAUTION FOR GENERAL VENTILATING USE
ONLY. DO NOT USE TO EXHAUST HAZARDOUS
OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION TO REDUCE RISK OF FIRE AND TO
PROPERLY EXHAUST AIR, BE SURE TO DUCT
AIR OUTSIDE. DO NOT VENT EXHAUST AIR
INTO SPACES WITHIN WALLS OR CEILINGS OR
INTO ATTICS, CRAWL SPACES OR GARAGES.
WARNING TO REDUCE THE RISK OF INJURY
TO PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING*:
A. SMOTHER FLAMES with a close-fitting lid,
cookie sheet or metal tray, then turn o the
burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE
DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN—You may
be burned.
C. DO NOT USE WATER, including wet dishcloths
or towels—a violent steam explosion will result.
D. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher,
and you already know how to operate it.
2. The fire is small and contained in the area
where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety” published by NFPA.
49-80589-7 3
READ AND SAVE THESE INSTRUCTIONS
SAFETY INFORMATION
SAFETY PRECAUTIONS
WARNING TO REDUCE THE RISK OF A
RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers may ignite. Heat oils slowly on low or
medium settings.
B. Always turn hood ON when cooking on high heat
or when flambéing food (i.e. Crepes Suzette,
Cherries Jubilee, Peppercorn Beef Flambé).
C. Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or filter.
D. Use proper pan size. Always use cookware
appropriate for the size of the surface element.
WARNING TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
B. Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guidelines and safety standards
such as those published by the National Fire
Protection Association (NFPA), the American
Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE) and the local
code authorities.
C. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
D. Ducted fans must always be vented to the
outdoors.
E. When applicable, install any makeup
(replacement) air system in accordance
with local building code requirements. Visit
GEAppliances.com for available makeup air
solutions.
F. Turn off breaker to adjacent rooms while
working.
WARNING TO REDUCE THE RISK OF FIRE,
USE ONLY METAL DUCTWORK.
Ŷ Do not attempt to repair or replace any part of
your hood unless it is specifically recommended
in this manual. All other servicing should be
referred to a qualified technician.


Product specificaties

Merk: GE
Categorie: Afzuigkap
Model: JN328KSA

Heb je hulp nodig?

Als je hulp nodig hebt met GE JN328KSA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap GE

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap