GE JD630DTWW Handleiding

GE Fornuis JD630DTWW

Lees hieronder de đź“– handleiding in het Nederlandse voor GE JD630DTWW (8 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT — Save these
instructions for local inspector’s use.
• IMPORTANT — Observe all governing
codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with consumer.
• Note to consumer – Keep these
instructions for future reference.
• Skill level – Installation of this appliance
requires a qualified installer or electrician.
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is
not covered under warranty.
FOR YOUR SAFETY:
If you did not receive an anti-tip bracket with your purchase,
call 1.800.626.8774 to receive one at no cost. (In Canada,
call 1.800.561.3344.) For installation instructions of the bracket,
visit: .)GEAppliances.com. (In Canada, GEAppliances.ca
Installation Instructions
30” Electric Drop-In Ranges
MATERIALS YOU MAY NEED TOOLS YOU WILL NEED
1 REMOVE PACKAGING MATERIALS
Failure to remove packaging materials could result in damage to the appliance. Remove all packing
parts from oven, racks, and heating elements. Remove protective film and labels on the outer door
and control panel. Also remove plastic on trims and panel and all tape around the oven. Open oven
door and remove literature pack and oven racks. Remove the bottom trim from the side of the oven.
It will be installed at the end of the installation process. The trim is wrapped separately in a plastic
bag which will also contain the 4 screws to secure the bottom trim and the 2 shoulder screws used
to secure the product to the cabinet.
Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit GEAppliances.com
In Canada, call 1.800.561.3344 or visit GEAppliances.ca
2 PREPARE THE OPENING (FOR INDOOR USE ONLY)
NOTE: Drop-In Ranges are designed to hang from the countertop only. Do not install on a platform
or sup port rails.
WARNING
Before
beginning the installation, switch power
off at service panel and lock the service
disconnecting means to prevent power
from being switched on accidentally.
When the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.
• child or adult can tip the range and be killed.A
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the
range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns
to children or adults.
Tip-Over Hazard
WARNING
• Junction Box
• Wire Nuts
• Strain Relief Clamp for 1/2” Conduit
Oven
Anti-Tip Bracket
Countertop or
Wood Block
Rear
Wall
• 1/8” Drill Bit and
Electric Drill
• Phillips Screwdriver
• Level
• Flathead Screwdriver
• Tape Measure
• 1/4” Nut Driver
• Straight edge or
Square
• Hammer
• Hand or Saber Saw
• Pencil
• Safety Glasses
Allow 30” minimum clearance between surface units and
bottom of unprotected wood or metal cabinet. Allow a 24”
minimum when bottom of wood or metal is protected by no
less than 1/4” thick flame retardant millboard covered with
not less than No 28 MSG sheet metal (.015”), .015” thick
stainless steel, .024” aluminum or .020” copper.
Overall Depth
23 1/2”
2
PREPARE THE OPENING (FOR INDOOR USE ONLY) (Cont.)
3 WHEN INSTALLING RANGE IN COUNTERTOP CUT
OUT TO WALL
If the counter opening extends to the walls, it will require maintop filler kit WB07T1068X or
backguard kit JXS32XX to close the gap. Refer to the filler or back guard kit instructions for
installation details.
NOTE: If the countertop is greater than 25” it will show a gap between the back-guard and wall or
between filler kit and the wall.
WARNING
An additional anti-tip bracket support must be mounted to the rear wall of the
cutout. The anti-tip bracket support is typically a 2x4 piece of lumber screwed directly into the wall
studs. The anti-tip bracket support must be able to withstand 200 lbs of force at the engagement point.
4 REMOVE OVEN DOOR
Door removal is not a requirement for installation of the product but is an
added convenience. To remove the door:
1. Open the oven door as far as it will go.
2. Push both hinge locks toward the door frame to the unlocked position. This
may require a flat blade screwdriver.
3. Place hands on both sides of the door, and close the door to
the removal position. This is half way between the broil stop
and fully closed.
4. Lift the door up and out until the hinge arms clear the slots.
Hinge
Clears Slot
Wall
1/4” min. flat
23-3/16”
9/16” min.
flat
9/16” min.
flat
29-15/16”– 30-1/16”
smooth cut
25”
typically
The Standard Installation of this Drop-In Range
is to hang by the countertop on the side metal
flang es under glass cooktop. This Range must
not be installed on a base or sub structure
(2”x 4” support).
If the construction of your cabinet cannot provide a 1/4” flat area at the back of the countertop
opening, consider changing the countertop to accommodate this dimension. If the area is not flat,
excess tension may be applied to the glass cooktop, causing breakage and voiding the warranty.
• Countertop thickness 1-1/4” min. is required to support the product. Braces must be installed
between the underside of the countertop and the cabinet if required to obtain 1-1/4” minimum
thickness (each side).
• Make sure the wall coverings, counters and cabinets around the oven can withstand the heat (up
to 200° F (93.3° C) generated by the oven.
• This appliance has been approved for 0” spacing to adjacent surfaces above the cooktop.
However, a 6” minimum spacing to surfaces less than 15” above the cooktop and adjacent
cabinet is recommended to reduce exposure to steam, grease splatter and heat.
• Locate the wiring junction box at the rear of the cutout. The dimension from the top of the wiring
junction box to the countertop must be a minimum of 28-1/2”. The box must not extend more than
3” off the plane of the wall. The junction box must be located where it will allow considerable slack
in the range conduit, so that the range can be pulled out for service if necessary.
1/4”
R
Flat
area
Countertop
Range support
29-15/16” Min.
30-1/16” Max.
10-3/8” from
countertop to
anti-tip support
25” 9/16”
9/16”
Must be Flat
Must be Flat
Anti-T
ip Support
Wall
Hinge Lock
(Unlocked
Position)
Hinge
Slot
Hinge Arm
5 ELECTRICAL REQUIREMENTS
WARNING Electric Shock Hazard
• This appliance must be properly grounded.
• Do not use an extension cord.
• Before installing range, switch power off at the service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the
disconnection means cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
Failure to follow these instructions may result in serious injury or death.
WARNING Fire Hazard
Improper connection of aluminum house wiring to copper leads can result in an electrical
or fire hazard. If residence leads are aluminum, use only connectors designed for joining
copper to aluminum and follow the manufacturer’s recommended procedure closely. Failure
to do so may result in serious injury or death. We recommend you have the electrical wiring
and hookup of your range connected by a qualified electrician. After installation, have the
electrician show you how to disconnect power from the range.
We recommend you have the electrical wiring and hookup of the appliance connected by a qualified
electrician. After installation, have the electrician show you how to disconnect power from the appliance.
You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 Hertz electrical system.
Effective January 1, 1996, the National Electrical Code requires that new construction (not existing)
utilize a four-conductor connection to an electric oven. When installing an electric oven in new
construction, a mobile home, recreational vehicle or area where local codes prohibit grounding
through the neutral conductor, refer to the section on four-conductor branch circuit connections.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven
according to governing code could result in a hazardous condition. If there are no local codes, your
oven must be wired and fused to meet the National Electrical Code, NFPA No. 70-latest edition,
available from the National Fire Protection Association.
Rating plate is located on oven front frame and is visible when oven door is open.
This appliance must supplied be with the proper voltage and frequency, and connected to an individual,
properly grounded, 40 amp (minimum) branch circuit protected by a circuit breaker or time-delay fuse.
DO NOT shorten the flexible conduit. The conduit strain relief clamp must be securely attached to
the junction box and the flexible conduit must securely attached to the clamp. If the flexible conduit
will not fit within the clamp, do not install the oven until a clamp of the proper size is obtained.
The 3 power leads supplied with this appliance are suitable for connection to heavier gauge
household wiring. The insulation of these 3 leads is rated for temperatures much higher than
the temperature rating of the household wiring. The current-carrying capacity of the conductor is
governed by the wire gauge and the temperature rating of the insulation around the wire.
MAKE ELECTRICAL CONNECTIONS
Place the unit on a platform or table even with the cutout opening. The platform must support 200
lbs. (91 kg). Connect the flexible conduit to the electrical junction box as follows:
THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE: If residence leads are aluminum conductors, see WARNING in section 5A, Electrical
Requirements.
When connecting to a three-conductor branch circuit, if local
codes permit:
1. Connect the oven ground conductor along with the neutral
(white) lead to the branch circuit neutral (white or gray in color),
using a wire nut.
2. Connect the oven red lead to the branch circuit red lead,
and the oven black lead to the branch circuit black lead in
accordance with local codes, using wire nuts.
3. Install proper strain relief clamp.
4. Install junction box cover.
5 ELECTRICAL REQUIREMENTS (Cont.)
FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE: If residence leads or ground are aluminum conductors, see WARNING in section 5A,
Electrical Requirements.
When connecting to a four-conductor branch circuit, if local codes permit:
1. Free the neutral (white) lead from being restrained to any other wires. If necessary, cut the
neutral (white) lead and then re-strip it to expose the proper
length of conductor.
2. Attach the appliance grounding lead (green or bare copper)
in accordance with local codes.
3. Connect the oven neutral (white) lead to the branch circuit
neutral (white or gray) in accordance with local codes, using
a wire nut.
4. Connect the oven red lead to the branch circuit red lead and
the oven black lead to the branch circuit black lead in ac cor-
dance with local codes, using wire nuts.
5. Install proper strain relief clamp.
6. Install junction box cover.
6 ANTI-TIP DEVICE INSTALLATION
WARNING
• To reduce the risk of tipping the range, the range must be properly secured to the
countertop or rear wall using the anti-tip suppport. (See section 3 for details.)
• Weight on the door could potentially cause the range to tip and result in injury. Never
allow anyone to climb, sit, stand, or hang on the oven door.
Installing the Anti-Tip Bracket
The anti-tip bracket
is attached to the
back of the Drop-
In Range. It is
designed to fit under
the bottom of the
countertop opening
at the rear. Measure
counter thickness
at back of cutout to
determine correct
bracket location.
Select the proper
position for the
countertop thickness
and move bracket
to proper position.
(Unit is sup plied with
brack et in po si tion 1.)
1. For 1.18” (3 cm)
Counter
2. For 1.5” Counter
3. For 3.5” Counter
4. Alternate (shown)
Branch
circuit
Black
Alternate
knockout
Neutral wire
connection
Range
conduit
snaps
into box
Red
Ground
and neutral
wires (white)
Tape or
Crimp
Branch
circuit
Black
Alternate
knockout
Range conduit
snaps into box
Red
White
Ground
wires
ANTI-TIP INSTALLATION
Interior wall
1/4” min.
flat area
Wall stud
Countertop
thickness
Bottom of
countertop
Wire cover
Maintop
Anti-tip
bracket
Bottom of
countertop
to engage
bracket by
1/2” min. Wall stud
10-3/8”
1-1/2”
Countertop
surface
Interior wall
Wire
cover
Attachment
anchored to wall
stud is required
Anti-tip bracket
Attachment
Non-kit ap pli ca tion
Maintop
Position #5 non-
kit application
*Attachment to engage
bracket by 1/2” min.
ALTERNATIVE INSTALLATION
OF THE ANTI-TIP INSTALLATION
ANTI-TIP BRACKET LOCATION
(REAR OF RANGE)
Cooktop
31-11041 Rev. 1 10-19 GEA


Product specificaties

Merk: GE
Categorie: Fornuis
Model: JD630DTWW

Heb je hulp nodig?

Als je hulp nodig hebt met GE JD630DTWW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis GE

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis