REQUIRED TOOLS AND ACCESSORIES
FOR INSTALLATION
2 Adjustable wrenches
Pipe cutter or hacksaw
File
Emery paper
Screwdriver
Additional installation parts may be required:
2 fittings to connect household plumbing to 1
female
NPT threads on filter housing. Installation Kit available
to connect to 3/4
copper plumbing:
GE Part/Retail Part (HDKIT)
(Not performance tested or certified by NSF.)
UL Approved grounding clamps and 6-gauge copper
grounding wire—Installation Kit available:
GE Part/Retail Part (HDKIT)
(Not performance tested or certified by NSF.)
Mounting Bracket (HDBRKT)
Teflon Tape
Sump Wrench
Retail Part (HDWRNCH)
GE Parts (WX5X3002)
Optional accessories are available (Visa, MasterCard or Discover cards
accepted) by visiting our Website at www.GEAppliances.com or from
Parts and Accessories, call 800.626.2002 (U.S.) or 800.663.6060 (Canada).
CONTENTS INCLUDED WITH PRODUCT
Filter housing and head
Product literature
1
GE Smar tWater
INSTALLATION INSTRUCTIONS
Heavy Duty Water Filtration System—GXWH30C (filters not included)
SAFETY PRECAUTIONS
Check with your state and local public works department
for plumbing and sanitation codes. You must follow these
guidelines as you install the Heavy Duty Water Filtration
System. Using a qualified installer is recommended.
Be sure the water supply conforms with the Performance
Data. If the water supply conditions are unknown, contact
your municipal water company
.
WARNING: Do not use with water that is
microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
I
t is highly recommended that a water shut-off valve be
placed directly upstream of your household filter.
Check with your local public works department for plumbing
codes. You must follow their guides as you install the
Heavy Duty Water Filtration System.
Use the Heavy Duty Water Filtration System on a potable,
safe-to-drink, home COLD water supply only. The filter
cartridge will not purify water or make unsafe water safe
to drink. DO NOT use on HOT water (100
°
F max).
Protect the Heavy Duty Water Filtration System and piping
from freezing. Water freezing in the system will damage it.
Your Heavy Duty Water Filtration System will withstand up to
100 psi water pressure. If your house water supply pressure
is higher than 100 psi during the day (it may reach higher
levels at night), install a pressure reducing valve before the
system is installed.
Do not install on HOT WATER. The temperature of the
water supply to the Heavy Duty Water Filtration System
must be between the minimum of 40
°F. and the maximum
of
1
00°F
. See the
Performance Data
section
.
Do not install the Heavy Duty Water Filtration System using
copper solder fittings. The heat from the soldering process
will damage the unit.
WARNING: Discard all unused parts and
packaging material after installation. Small parts
remaining after installation could be a choke hazard.
Do not install filter in an outside location or anywhere it
will be exposed to sunlight.
PROPER INSTALLATION
This Heavy Duty Water Filtration System must be properly installed and located in accordance with the Installation Instructions
before it is used.
GXWH30C is
Tested and Certified by NSF International
against ANSI/NSF
Standard 42 with Cartridge FXHTC
for the reduction of Chlorine: Taste and Odor.
251B6021P002 49-50048-6 145287 Rev. D(03-02 JR)
www.GEAppliances.com
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
2
CARTRIDGE SPECIFICATIONS
Filter Cartridge Replacement
You should change your filter when the water flow is noticeably reduced or at least every three months.
Influent Challenge Reduction Average
Substance Concentration Requirements Reduction
Standard 42
Chlorine 2.0 mg/L ± ≥10% 50% 95.5%
Turn off water to filter. Water must be shut off
from an upstream valve.
Press the red pressure release button to release
pressure.
Unscrew the filter canister and discard used
filter. Wash the filter canister with mild soap
and water. Do not use harsh cleaners or hot
water.
Inspect the filter canister O-ring. Make sure
it is lightly lubricated and completely seated
in the groove. It is recommended that you
replace the O-ring if it is damaged.
Place a new filter cartridge into the canister,
making sure it is centered and completely
seated on the bottom seal.
Reinstall the filter canister to the unit. Hand
tightening is all that is required to seal the
unit. DO NOT OVERTIGHTEN.
Slowly turn on water to the filter by using the
upstream shut-off valve.
Press the red pressure release button to
remove trapped air.
After installation, flush the cartridge for
10 minutes, wait one hour, then flush again
for 10 minutes before using the water.
9
8
7
6
5
4
3
2
1
Installation Overview
NOTE: Be sure to allow a minimum space
of 11⁄ –22 under the filter for removing
the sump to change the cartridge.
Turn sump wrench tool
clockwise to remove
Sump
Turn
clockwise
to remove
canister
Turn
counterclockwise
to tighten
Red pressure
release button
Filter
cartridge O-ring seal
Filter canister
Head
Performance Data
This system has been tested according to ANSI/NSF 42
for the reduction of the substances listed below. The
concentration of the indicated substances in water
entering the system was reduced to a concentration
less than or equal to the permissible limit for water
leaving the system, as specified in ANSI/NSF 42.
STEP-BY-STEP INSTALLATION INSTRUCTIONS
Recommended
shut-off valve
Recommended
shut-off valve
Adapter
Ferrule
Hex nut
Adapter
Ferrule
Hex nut
112–2
Typical installation
FXHTC Cartridge
Test Conditions
Flow Rate: 3 gpm (11.4 Lpm)
pH: 7.5 ±1
Inlet Pressure: 60 PSI (4.1 bar)
Temperature: 68°F ± 5°F (19.8°C ± 2.5°C)
Operating Requirements
Pressure: 30–100 PSI (2.1–6.9 bar)
Turbidity: 5 NTU Max.
Temperature: 40°F–100°F (4.4°C–37.7°C)
Capacity: 5,000 gallons (18,927L) or 3 months
Testing was performed under standard laboratory conditions, actual performance may vary.
3
STEP-BY-STEP INSTALLATION INSTRUCTIONS (cont.)
Select Location
Select a location for the filter that is:
protected from freezing.
not exposed to direct sunlight.
It is recommended that a shut-off valve be placed on both sides
of the filter.
It is recommended that a mounting bracket be used.
Install Fittings
Instructions are for installing fittings for the HDKIT or similar
fittings onto copper plumbing. If the unit is to be installed on
any other type of tubing (plastic, PVC, galvanized), different
hardware must be purchased. See instructions with additional
hardware purchased or consult a qualified plumber.
Apply 4 or 5 wraps of Teflon tape, in a clockwise direction,
to the pipe threads (coarse) of each adapter. DO NOT use
joint compound on any parts connecting to filter housing.
Assemble an adapter to the inlet and outlet of the head. Start
each fitting by hand to make sure they don’t cross thread.
Use an adjustable wrench firmly. DO NOT OVERTIGHTEN.
About one to two thread(s) should remain visible.
Cut Water Line
Turn off water supply and open a nearby faucet to drain
water out of pipes.
Remove the nut and brass ferrule from both compression
fittings and set aside. Using a tape measure or ruler,
measure the distance D” as shown.
NOTE: I
t is recommended that the shut-off valve be placed
before and after the filter as shown in the Installation
Overview illustration.
Select the location for the filter. Mark the distance “D”
on the pipe.
Using a pipe cutter or hacksaw, cut pipe. Sand (file) cut
ends of pipe to assure that they are square and smooth.
3
2
1
Installing the Unit
Align filter assembly with pipe ends making certain that
the incoming water supply is going into the filter opening
marked “IN”. It may be necessary to spread the pipe ends
apart to install filter assembly.
Using two adjustable wrenches, hold incoming adapter
securely with one wrench and tighten nut with second
wrench. Repeat this procedure for outgoing adapter.
If necessary, support the water pipe on either side of the
filter unit.
3
2
1
Final Check
Install filter (see Filter Cartridge Replacement Section).
Slowly turn on water supply.
Check entire system for leaks.
If leaking, shut off water pressure and tighten or reseal
fittings.
After installation, flush the cartridge for 10 minutes,
wait one hour, then flush again for 10 minutes before
using the water.
5
4
3
2
1
Teflon tape
D
Attach Fittings to Water Line
Slip a compression nut onto each pipe.
Next, slip the brass ferrule onto each pipe.
2
1
Nut
Brass ferrule
Nut
Brass ferrule
D
Installing the Ground Wire
IMPORTANT: A copper or galvanized house cold water pipe
is often used to ground electrical outlets in the home.
Grounding protects you from electrical shock. The water filter
housing may have broken this ground path. To restore
connection, install an 18long, 6-gauge copper wire across
the filter, tightly clamped using UL approved 1/2–1bronze
grounding clamps at both ends as shown. Zinc clamps should
not be used on copper plumbing. Wire and clamps may be
purchased separately from your local hardware store, or are
available by visiting our Website at www.GEAppliances.com
or from Parts and Accessories, call 800.626.2002 (U.S.) or
800.663.6060 (Canada)—order part number HDKIT.
Clean copper pipe and ends of wire with emery paper.
Bare wire is recommended. If insulated wire is used,
it should be stripped 3/4at each end before cleaning
with emery paper.
Attach bronze clamps to copper pipe. Tighten screws.
Attach wire to clamps as shown. Tighten screws.
NOTE: I
f your house plumbing is plastic, it would not be used
as a grounding path, and this step should be skipped.
3
2
1
Clamp
Ground wire


Product specificaties

Merk: GE
Categorie: Waterfilter
Model: GXWH30C

Heb je hulp nodig?