BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT – Save these instructions for local
electrical inspector’s use.
• IMPORTANT – Observe all governing codes and
ordinances.
• Install the clothes dryer according to the manufacturer’s
instructions and local codes.
• Note to Installer – Be sure to leave these instructions
with the Consumer.
• Note to Consumer – Keep these instructions for future
reference.
• Clothes dryer installation must be performed by a
qualified installer.
• This dryer be exhausted to the outdoors. must
• Before the old dryer is removed from service or
discarded, remove the dryer door.
• Service information and the wiring diagram are located
in the control console.
• Do not allow children on or in the appliance. Close
supervision of children is necessary when the appliance
is used near children.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
• Install the dryer where the temperature is above 50°F
for satisfactory operation of the dryer control system.
• Remove and discard existing plastic or metal foil duct
and replace with UL-listed duct.
Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com
- Fire Hazard
WARNING
• Clothes dryer installation must be performed by a
qualified installer.
• Install the clothes dryer according to these
instructions and local codes.
• DO NOT install a clothes dryer with flexible plastic
venting materials. If flexible metal (semi-rigid or
foil-type) duct is installed, it must be UL-listed and
installed in accordance with the instructions found
in “Connecting the Dryer to House Vent” later in
this manual. Flexible vent materials are known to
collapse, be easily crushed and trap lint. These
conditions will obstruct dryer airflow and increase
the risk of fire.
• DO NOT install or store this appliance in any
location where it could be exposed to water or
weather.
• To reduce the risk of severe injury or death, follow
all installation instructions.
• Save these instructions. (Installers: Be sure to leave
these instructions with the customer.)
Installation Electric Dryers
Instructions 02
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill you or hurt you and others.
All safety messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”. These
words are defined as:
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
DANGER
WARNING
CAUTION
Printed in Mexico 234D2008P002
31-16726-3 04-16 GEA
2
Installation Instructions
Tilt the dryer sideways and remove the foam
shipping pads by pulling at the sides and breaking
them away from the dryer legs. Be sure to remove all
of the foam pieces around the legs.
Remove the bag containing the literature.
UNPACKING YOUR DRYER
POWER CORDS:
GE Appliances strongly recommends the use of factory
specified parts. Select the power cord to fit your installation
requirements.
Order on-line at GEApplianceParts.com, 24 hours a day or
by phone at 800.626.2002 during normal business hours.
Part Number Type Length Amperage
WX9X2 3-Prong 4 Feet 30
WX9X3 3-Prong 5 Feet 30
WX9X4 3-Prong 6 Feet 30
WX9X18 4-Prong 4 Feet 30
WX9X19 4-Prong 5 Feet 30
WX9X20 4-Prong 6 Feet 30
4 3/8”
(11.11 cm)
Y
ROUGH-IN
DIMENSIONS
Side View
NOTE:
With Pedestal: 52 3/8” (133 cm)
Stacked: 79 5/8” (202.25 cm)
X
39 3/8”
(100 cm)
27”
(68.6 cm)
39 3/8”
(100 cm)
Front View
X
32 3/16” (81.76 cm) 7.0 cu. ft.
models
33” (83.80 cm) 7.5 cu. ft.
models
Y
4 1/2” (11.43 cm) 7.0 cu. ft.
models
5 3/8” (13.65 cm) 7.5 cu. ft.
models
Installation Instructions
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
MOBILE OR MANUFACTURED HOME
INSTALLATION
3
- Explosion Hazard
WARNING
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
• Installation must conform to the
MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24, PART 32–80 or
Standard CAN/CSA-Z240 MH, or, when such
standard is not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 501B.
• The dryer MUST be vented to the outdoors. The
exhaust vent must be securely fastened to a
non-combustible portion of the mobile home.
• The vent MUST NOT be terminated beneath a
mobile or manufactured home.
• The vent duct material MUST BE METAL.
• KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
• The vent MUST NOT be connected to any other
duct, vent or chimney.
• Do not use sheet metal screws or other
fastening devices which extend into the interior
of the exhaust vent.
• Provide an opening with a free area of at least
25 square inches for introduction of outside air
into the dryer room.
• See the sections for electrical connection
information.
• The dryer MUST be vented to the outdoors. See
the EXHAUSTING THE DRYER section.
• Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0” either side
3” front
3” rear
1” top
• Consideration must be given to provide adequate
clearance for installation and service.
• Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches of
open area. If the closet contains both a washer
and a dryer, doors must contain a minimum of
120 square inches of open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED IN
THE REAR OF THE DRYER, THE CONFIGURATION OF
THE DUCTING MAY REQUIRE GREATER THAN 3” OF
REAR CLEARANCE.
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and
for air opening are: 0” both sides; 3” rear; 1” top.
Consideration must be given to provide adequate
clearance for installation and service.


Product specificaties

Merk: GE
Categorie: Wasdroger
Model: GFDL110EHWW

Heb je hulp nodig?

Als je hulp nodig hebt met GE GFDL110EHWW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Wasdroger GE

Handleiding Wasdroger

Nieuwste handleidingen voor Wasdroger