GE DCVH680GJBB Handleiding

GE Wasdroger DCVH680GJBB

Lees hieronder de đź“– handleiding in het Nederlandse voor GE DCVH680GJBB (14 pagina's) in de categorie Wasdroger. Deze handleiding was nuttig voor 32 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/14
Step 1 Verify Your Gas Installation (see section 2).
Step 2 Prepare the Area and Exhaust for Installation of New
Dryer (see section 1) .
Step 3 Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Speci ications. (see section 6)f .
Step 4 Remove the Foam Shipping Pads (see section 1).
Step Mo the Dryer to the Desired Location 5 ve .
Step 6 Level Your Dryer (see section 8).
Ste Conne the Gas Supply (see section and heck fop 7 ct 3) c r
leaks (see section 4) .
Step Connect the External Exhaust (see section 7) 8 .
Step Connect the er Supply (see section 5) 9 Pow .
Step 10 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11 Place the Owners Manual and the Installation
Inst uctions in Location Where They illr a W Be
Noticed By the Owner.
For Alcove or Closet Installation see section 9.
For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured Home see section 11.
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
If you ha ve any questions, call 1- -GECARES (US)800 or 1- -561-3344 (Canada800 )
or Vis it our Web si te a t: www. c .com GEApplian es (US)
Installation
Instructions
Gas Dr rye
10
PEDESTALS FOR DRYERS
(comes with individual installation instructions)
3 models available:
500A436P010 Pub# 31-16229
In the state of Massachusetts, installation must be performed by a qualified or
licensed contractor, plumber, or gasfitter qualified or licensed by the state.
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT- Save these
instructions for local inspector’s use.
•
IMPORTANT- Observe
all governing codes and ordinances.
•
Note to Installer- Be sure to leave these
instructions with the customer.
•
Note to Customer- Keep these
instructions with your Use and Care Book
for future reference.
•
Before the old dryer is removed from
service or discarded, remove the dryer door.
•
Service information and the wiring diagram
are located in the control console.
•
D
o not allow children on or in the appliance.
Close supervision of children is necessary
when the appliance is used near children.
•
Install the dryer where the temperature is
above 50°F for satisfactory operation of
the dryer control system.
•
•Inspect the dryer exhaust outlet and
straighten the outlet walls if they are bent.
MATERIALS YOU WILL NEED
LEVEL
8" PIPE WRENCH
EXHAUST HOOD
FLEXIBLE GAS LINE CONNECTOR
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
DUCT TAPE
GLOVES
SAFETY GLASSES
4" DIAM METAL ELBOW
10" ADJUSTABLE WRENCHES
(x2)
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
(x2)
(x2)
TOOLS YOU WILL NEED
SLIP JOINT PLIERS FLAT BLADE SCREWDRIVER
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
To reduce the risk of severe injury or death, follow all installation instructions.
• Clothes dryer installation must be performed by a qualified installer.
• Install the clothes dryer according to these instructions and in accordance with local codes. In
the absence of local codes, installation must comply with National Fuel Gas Code,
ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
• This dryer must be exhausted to the outdoors.
This act requires the governor of California to publish a list of substances known to the state to
cause cancer, birth defects or other reproductive harm and requires businesses to warn
customers of potential exposure to such substances. Gas appliances can cause minor
exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and
soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Properly
adjusted dryers will minimize incomplete combustion. Exposure to these substances can be
minimized further by properly venting the dryer to the outdoors.
•
California Safe Drinking Water and Toxic Enforcement Act
• Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors.
• Do not install or store this appliance in any location where it could be exposed to water and or
weather.
• Save these instructions. (Installers: Be sure to leave these instructions with the customer).
• DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible metal (semi-
rigid or foil-type) duct is installed, it must be UL-listed and installed in accordance with the
instructions found in "Connecting The Dryer To House Vent" on page 6 of this manual. Flexible
ducting materials are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct dryer airflow and increase the risk of fire.
- R K F REIS O FI
WARNING
•
SBSD227F, SBSD137H
SBSD107H
INTERNAL DUCT
OPENING CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
Inst tion Instructionsalla
Minimum Clearance her Than Alc ve Ot o or Cl se ns allao t I t tion
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration
must be given to provide adequate clearance for proper operation and service.
1PREPARING FOR INSTALLATION
OF NEW YERDR 2GAS REQUIREMENTS
GAS SUPPLY
•A 1/8-in. National Pipe Taper thread plugged tapping, acces-
sible for test gauge connection, must be installed immediat yel
upstream of the gas supply connection to the dryer. Contact
your local gas utility should you have questions on the
installation of the plugged tapping.
•Supply line is to be 1/2-in. rigid pipe and equipped with an
accessible shut-off within 6 ft. of, and in the same room with,
the dryer.
•Use r s co o o for or LPpipe th ead ealer mp und appr priate natural
ga efl tapes or use T on .
•Connect flexible metal connector to dryer and gas supply.
•Open shut-off valve.
•You must use with this dryer a flexible metal connector listed
connector ANSI Z21.24 / CSA 6.10. The length of the connect
shall not exceed 3 ft.
2
W ARNING - NEVER REUSE OLD
FL XIBLEE CONNEC ORT S.
The use of old flexible connectors can cause leaks and
personal injury. Always use n flexible connectors whenew
installing gas app iances l .
REM VING INTO L FROM WALL
EXH USA T GOPENIN
WARNING
•Installation must conform to local codes and ordinances,
or in their absence, the NATIONAL FUEL GAS CODE,
ANSI Z223.
•This gas dryer is equipped with a Valve & Burner
Assembly for use only with natural gas. Using conversion
kit WE25X0217, your local service organization can
convert this dryer for use with propane (LP) gas. ALL
CONVERSIONS MUST BE MADE BY OPER PR LY TR DAINE
AND QUALIFIED PERSONNEL AND IN ACCORDANCE WITH
LOCAL CODES AND ORDINANCE REQUIREMENTS.
•The dryer must be disconnected from the gas supply
piping system during any pre ure testing of that systemss
at a test pre ure in exce of 0.5 PSI (3.4 KPa).ss ss
•The dryer must be isolated from the gas supply piping
system by closing the equipment shut-off valve during
any pressure testing of the gas supply piping of t tes
pressure equal to or less than 0.5 PSI (3.4 KPa).
DRYER GAS SUPPLY CONNECTION
2"
2-5/8" 3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
TURN GAS
SHUT-OFF
VALVE TO THE
OFF POSITION.
DISCONNECTING GAS
Tilt the dryer sideways
and remove the foam
shipping pads by
pulling at the sides
and breaking them
away from the dryer
legs. Be sure to
remove all of the
foam pieces around
the legs.
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust
•Remove and discard existing plastic or metal foil transition duct and
replace with UL listed transition duct.
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD DUCTING MATERIAL.
REPLACE WITH NEW CSA(AGA)
APPROVED FLEXIBLE GAS LINE
CONNECTOR AND UL APPROVED
TRANSITION DUCT.
OPEN
GAS VALVE.
APPLY PIPE COMPOUND
TO ALL MALE THREADS.
Tighten all connections using two adjustable wrenches.
Do not overtorque gas connections!
APPLY PIPE COMPOUND
TO THE ADAPTER AND
DRYER GAS INLET.
NEW METAL
FLEXIBLE GAS
LINE CONNECTOR
ADAPTER
ELBOW
ITEMS NOT SUPPLIED
ADAPTER
SHUT-OFF
VALVE
PIPE SIZE
AT LEAST 1/2"
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
3/8" NPT
Tighten the flexible
gas line using two
adjustable wrenches.
Inst tion Instructionsalla
3RE ONNECTINGC GAS
3
WARNING - NE VER USE AN O NPE
FL E TO T T AM ES FOR GAS LE S.AK
4 LE AK TEST
Check all connections for leaks with soapy solution or equivalent.
Apply soap solution. Leak test solution must not contain ammo-
nia which could cause damage to the brass fittings. areIf leaks
found, close valve, r igh n the joint, and peat the soap t t.et te re es
Note: The connector and fittings are designed for use only on the
original installation and are not to be reused for another appliance
or at another location. Keep flare end of adaptor free of grease, oil
and thread sealant.
Caution: Use adapters as shown. Connector nuts must not be
connected directly to pipe threads.
Listed connector ANSI Z21.24 / CSA 6.10


Product specificaties