Furrion F30-ATS Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Furrion F30-ATS (12 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 54 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
30amp 125V Automatic Transfer Switch
F30-ATS
Furrions ATS is used to safely switch automatically between mutiple power sources
.NOIRRUF C MO
.NOIRRUF C MO
Furrions 30amp Automatic Transfer Switch with its Safe Switch Relay is used to automatically
switch between two separate 120 volt AC power sources, these power sources can be from a
generator, shore power cord or inverter.
The function of the 30amp Furrion Automatic Transfer Switch is to provide a safe and smooth
switch over from an inverter or shore power cord automatically when a generator is started
and brought online, using the added feature of a mechanical switch between contactors to
ensure both power sources cannot be closed together which could otherwise create an over
voltage situation on the output line.
The electrical contacts in the transfer switch are normally in the closed position for the
shorepower feed.
Once AC power from the Generator is sensed by the transfer switch, this will start a timer and
automatically switch over to generator power supply after a 20-30 second delay, this is ensures
the generator has sufficient time to run up to speed before electrical load is applied.
The transfer switch also has a added feature of a time delay bypass switch which will remove
the 20 – 30second switching delay making it instantaneous.
INSTALLATION
PLEASE READ ALL SAFETY INSTRUCTIONS BEFORE INSTALLING THIS TRANSFER SWITCH!
WHEN PROTECTED BY A MOLDED CASE CIRCUIT BREAKER RATED TO 30AMPS OR LESS,
THIS LINE/GENERATOR SWITCH IS RATED TO 5000 SYMMETRICAL AMPS.
BEFORE PREFORMING MAINTENANCE OR INSTALLATION PLEASE ENSURE TO ISOLATE ALL
POWER SOURCES!
DO NOT USE THIS TRANFER SWITCH FOR MEDICAL PURPOSES OR LIFE SUPPORT.
Ensure generator is shut off and auto start feature (if applicable) is isolated.
Confirm external power cord is disconnected and stored in an area where it cannot
mistakenly be plugged in.
Confirm the inverter (if used) has been disconnected.
Confirm with an AC/DC electrical tester that no voltage is present at any of the connections
before beginning installation or maintenance.
Label all electrical parts with a warning tag to show work is in progress before beginning
work.
.NOIRRUF C MO
INSTALLING YOUR F30-ATS:
There are 3 common installation configurations for the Furrion ATS series:
Configuration 1: Double power feed
This is the standard installation used between a shore power cord and generator.
Input 2 Input 1
F30-ATS
Transfer switch
Output feed
DISTRIBUTION PANEL /
BRANCH CIRCUITS
30Amp Generator/Power Cord
System Wiring
Ty l Rpica V Wir Lay ting ou
EXAMPLE. 1
SHORE POWER CORD
30Amp 120 VAC 3.75KW
FURRION PULL SMART PLUG FEATURED BELOW
GENERATOR
30Amp 125 VAC 3.75KW Generator
Input 2 Input 1
F30-ATS
Transfer switch
Output feed
GENERATOR
30Amp 125 VAC 3.75KW Generator
SHORE POWER CORD
30Amp 125 VAC 3.75KW
FURRION PULL SMART PLUG FEATURED BELOW
DISTRIBUTION PANEL /
BRANCH CIRCUITS
Input 2 Input 1
F30-ATS
Transfer switch
Output feed
POWER INVERTER
MAX 3000W
EXAMPLE. 2
Main Power Supply Wiring, with
30amp Sub Panel Inverter Feed.
Configuration 2: Triple power feed (same rating)
This configuration is used when a inverter is added to the system and requires automatic
switch over. See Diagram 2 which illustrates this configuration


Product specificaties

Merk: Furrion
Categorie: Niet gecategoriseerd
Model: F30-ATS

Heb je hulp nodig?

Als je hulp nodig hebt met Furrion F30-ATS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Furrion

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd