Bekijk gratis de handleiding van Fujitsu ASHG12LMCA (8 pagina’s), behorend tot de categorie Airco. Deze gids werd als nuttig beoordeeld door 21 mensen en kreeg gemiddeld 4.2 sterren uit 3 reviews. Heb je een vraag over Fujitsu ASHG12LMCA of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/8

En-1
Safety Precautions
To prevent personal injury, or property damage, read this section carefully before you use this product, and be sure to comply following safety
precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classifi ed as follows:
WARNING CAUTION
This mark warns of death or serious injury.This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.This mark denotes an action that is COMPULSORY.
WARNING
• This product contains no user-serviceable parts. Always
consult authorized service personnel for repairing,
installation, and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or fi re.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
• In the event of refrigerant leakage, be sure to keep away
from fire or any flammables, and consult authorized service
personnel.
• In the event of a thunder storm or any prior sign of a lightning
strike, turn off the air conditioner via the remote controller,
and refrain from touching the product or the power source to
prevent any electrical hazards.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
• Do not start or stop the operation of this product by inserting
or pulling out the power plug, or by turning on or off the
circuit breaker.
• Do not use flammable gases near this product.
• Do not expose yourself directly to the cooling airfl ow for
many hours.
• Do not insert your fingers or any other objects into outlet
port, open panel, or intake grille.
• Do not operate with wet hands.
CAUTION
• Provide occasional ventilation during use.
• Always operate this product with air fi lters installed.
• Ensure that any electronic equipment is at least 1 m (40 in)
away from either the indoor unit or outdoor unit.
• Disconnect all the power supply when you are not using this
product for extended periods.
• After a long period of use, ensure to get the mounting of the
indoor unit checked to prevent this product from falling down.
• The airflow direction and the room temperature should be
carefully considered when you use this product in a room
with infants, children, elderly or sick persons.
• Do not place any other electrical products or household
belongings under this product.
Dripping condensation from this product might get them wet,
and may cause damage or malfunction of your property.
• Do not expose this product directly to water.
• Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects. This
may cause quality deterioration of those items.
• Do not expose animals or plants to the direct airfl ow.
• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable.
• Do not touch the aluminum fins of heat exchanger built-in
this product to avoid personal injury when you maintain the
unit.
• Do not direct the airfl
ow at
fi replaces or heating apparatus.
• Do not block or cover the intake grille and the outlet port.
• Do not apply any heavy pressure to radiator fi ns.
• Do not climb on, place objects on, or hang objects from this product.
PART No. 9333003047-04
[Original instructions]
Português E vIkλλη άItaliano Español Français Deutsch English
Türkçe Русский
AIR CONDITIONER
Wall Mounted Type
OPERATING MANUAL
Before using this product, read these instructions thoroughly and keep this manual for future reference.
Contents
Safety Precautions ............................................................... 1
Indoor Unit Overview and Operations .................................. 2
Remote Controller Overview and Operations ....................... 3
Timer Operation.................................................................... 5
General Information on Operation ........................................ 5
Care and Cleaning................................................................ 6
Troubleshooting .................................................................... 8
This product contains fl uorinated greenhouse gases.
Product specificaties
| Merk: | Fujitsu |
| Categorie: | Airco |
| Model: | ASHG12LMCA |
| Kleur van het product: | Wit |
| Timer: | Ja |
| Soort: | Splitssysteem |
| Air conditioner functies: | Cooling,Dehumidifying,Heating |
| Seizoensgebonden rendement (koeling) (SEER): | 7 |
| Seasonal efficiency rating (verwarming) (SCOP) (gemiddeld stookseizoen): | 4 |
| Energie-efficiëntieklasse (verwarming) (gemiddelde stookseizoen): | A+ |
| Jaarlijks energieverbruik (koelen): | 170 kWu |
| Jaarlijks energieverbruik (verwarming) (warmer stookseizoen): | - kWu |
| Jaarlijks energieverbruik (verwarming) (gemiddelde stookseizoen): | 1225 kWu |
| Energie-efficiëntieklasse (koeling): | A++ |
| Extern geluidsniveau: | 50 dB |
| Intern geluidsniveau (hoge snelheid): | 43 dB |
| Luchtstroom: | 750 m³/uur |
| Koelcapaciteit in watt (opgegeven): | 3400 W |
| Verwarmingscapaciteit in watt (opgegeven) (warmer stookseizoen): | - W |
| Verwarmingscapaciteit in watt (opgegeven) (gemiddelde stookseizoen): | 4000 W |
| Verwarmingscapaciteit in watt (opgegeven) (kouder stookseizoen): | - W |
| Energieverbruik per uur (koeling): | - kWu |
| Energieverbruik per uur (verwarming): | - kWu |
| Breedte binnenunit: | 840 mm |
| Diepte binnenunit: | 203 mm |
| Hoogte binnenunit: | 268 mm |
| Ontvochtiging capaciteit: | 1.8 L/u |
| Koel capaciteit in watt (max): | 3900 W |
| Verwarmingscapaciteit in watt (max): | 5300 W |
| Koeling energie efficientie: | 3.5 |
| Verwarming energie efficientie: | 3.92 |
| Indoor unit type: | Muur-montage |
| Indoor eenheid gewicht: | 8500 g |
| Jaarlijks energieverbruik (verwarming) (kouder stookseizoen): | - kWu |
| Ontwerpbelasting (koeling): | - kW |
| Ontwerpbelasting (verwarming) (warmer stookseizoen): | - kW |
| Ontwerpbelasting (verwarming) (gemiddelde stookseizoen): | - kW |
| Ontwerpbelasting (verwarming) (kouder verwarmingsseizoen): | - kW |
| Outdoor eenheid gewicht: | 26000 g |
| Breedte buitenunit: | 663 mm |
| Diepte buitenunit: | 293 mm |
| Hoogte buiteneenheid: | 535 mm |
| AC-ingangsspanning: | 230 V |
| AC-ingangsfrequentie: | 50 Hz |
| Energieverbruik (koelen) (max): | 970 W |
| Energieverbruik (verwarmen) (max): | 1020 W |
| Koelcapaciteit in watt (min): | 900 W |
| Verwarmingscapaciteit in watt (min): | 900 W |
| Timerduur (maximum): | 24 uur |
Heb je hulp nodig?
Als je hulp nodig hebt met Fujitsu ASHG12LMCA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Fujitsu
4 Mei 2026
1 November 2025
15 Mei 2025
14 Mei 2025
14 Mei 2025
14 Mei 2025
12 Mei 2025
12 Mei 2025
3 April 2025
29 Maart 2025
Handleiding Airco
Nieuwste handleidingen voor Airco
6 Mei 2026
6 Mei 2026
6 Mei 2026
5 Mei 2026
5 Mei 2026
5 Mei 2026
5 Mei 2026
5 Mei 2026
5 Mei 2026
5 Mei 2026