Bekijk gratis de handleiding van Festo VMPA14-HS (1 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 8 mensen en kreeg gemiddeld 4.9 sterren uit 7 reviews. Heb je een vraag over Festo VMPA14-HS of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/1

VMPA...-HS
Vertical pressure shut-off plate
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Deutschland
+49 711 347-0
www.festo.com
Assembly instructions
8150088
2021-08a
[8150090]
Translation of the original instructions
© 2021 all rights reserved to Festo SE & Co. KG
1
Applicable documents
All available documents for the product
è
www.festo.com/sp.
2Safety
2.1Safety instructions
–
Only use the product in its original condition without unauthorised modifica-
tions.
–Only use the product if it is in perfect technical condition.
–
Before working on the product, switch off the compressed air supply and lock it
to prevent it from being switched on again.
2.2Intended use
The vertical pressure shut-off plate enables replacement of a valve under oper-
ating pressure.
2.3
Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have knowledge
and experience in pneumatics.
3Additional information
–
Contact the regional Festo contact if you have technical problems
è
www.festo.com.
4Product Range Overview
4.1Scope of delivery
1
2
3
4
Fig.1
1
Vertical pressure shut-off plate (1x)
VMPA...-HS
2
Washer (2x)
3
Distance piece (2x)
4
Fibre optic cable extension (1x)
4.2Not in scope of delivery
5
Fig.2
5
Solenoid valve
VMPA...-M1H-…-PI
5Assembly
5.1Preparation
4
6
Fig.3
•Push the fibre optic cable extension onto the electronics module .46
5.2Assembly
1
2
3
7
8
Fig.4
1.
Check that the conical ring seal is positioned correctly.7
Ä
The tapered side is at the bottom
2.
Place the vertical pressure shut-off plate on the electronics module .18
3.
Place the washers in the lateral slots with the rounding outwards.2
4.
Tighten the distance pieces . Observe the tightening torque.3
Vertical pressure shut-
off plate
Spanner size of the dis-
tance pieces
Tightening torque
VMPA1-HS 20.4 Nm ± 10 %ß
VMPA14-HS 20.5 Nm ± 20 %ß
1
5
9
10
Fig.5
1.Check that the conical ring seal is positioned correctly on the solenoid9
valve .5
Ä
The tapered side is at the bottom
2.
Place the solenoid valve on the vertical pressure shut-off plate .51
3.Tighten the screws . Observe the tightening torque.aJ
Solenoid valveScrewTightening torque
VMPA1-M1H-...U-PIM2x400.25 Nm ± 10 %
VMPA1-M1H-...-PIM2x430.25 Nm ± 10 %
VMPA14-M1H-...-PIM2.5x450.65 Nm ± 10 %
Product specificaties
| Merk: | Festo |
| Categorie: | Niet gecategoriseerd |
| Model: | VMPA14-HS |
Heb je hulp nodig?
Als je hulp nodig hebt met Festo VMPA14-HS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Festo
2 Augustus 2025
2 Augustus 2025
1 Augustus 2025
1 Augustus 2025
1 Augustus 2025
1 Augustus 2025
1 Augustus 2025
1 Augustus 2025
1 Augustus 2025
1 Augustus 2025
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
23 Januari 2026
23 Januari 2026
23 Januari 2026
23 Januari 2026
23 Januari 2026
23 Januari 2026
23 Januari 2026
23 Januari 2026
23 Januari 2026
23 Januari 2026