Festo CPE18-PRSGO-2 Handleiding
Festo Niet gecategoriseerd CPE18-PRSGO-2
Bekijk gratis de handleiding van Festo CPE18-PRSGO-2 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 6 mensen. Heb je een vraag over Festo CPE18-PRSGO-2 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

CPE...-PRS
Connection block
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Deutschland
+49 711 347-0
www.festo.com
Operating instructions
8151076
2021-03g
[8151078]
Translation of the original instructions
© 2021 all rights reserved to Festo SE & Co. KG
1
Applicable documents
All available documents for the product
è
www.festo.com/sp.
2Safety
Safety instructions
Only use the product in original status without unauthorised modifications.
Intended use
The manifold blocks CPE...- PRS connect directional control valves to central
supply ports and are intended for wall or H-rail mounting.
3
Additional information
–Accessories
è
www.festo.com/catalogue.
4
Product overview
Structure
1
23
4
Fig.1
1
Connecting component
2
Valve spool
3
Blind plate
4
Mounting slide
Function
The manifold block CPE...-PRSG-2/-3 (double or triple) connects type CPE 5/2- or
5/3-way valves to central supply ports.
Two additional valves can be supplied with the help of the extension plate CPE...-
PRS-2.
The end plate CPE...-PRS-EP can be used to create different pressure zones or a
two-sided compressed-air supply.
The maximum configuration level is:
6 valves12 valves
–
with one-sided compressed-air supply or
–for every pressure zone
–
with two-sided compressed-air supply
Tab. 1
The CPE-...-PRSO-... have the diaphragms removed.
5Assembly
Preparation
Fig.2
1.Place all manifold blocks in their assembly sequence.
2.Trace the pressure curve, e.g. with a sketch.
When using multiple pressure zones:
NOTICE
•Make sure that the diaphragms at the interface of two pressure zones remain
intact.
Pressed-in diaphragms cannot be closed again. In doing so, consider
removing the diaphragms of the compressed air ducts for an unobstructed
flow rate.
Removing unused diaphragms:
Fig.3
1.
Press in the 3 diaphragms of the compressed air ducts on the manifold block
from the outside inwards in accordance with the pressure curve sketch using
a punch (A)
2.
Deburr fracture margins and
3.
Remove chips.
This time-saving method of operation results in irregular broken edges compared
to precision machining.
Assembly
H-rail mounting:
1.
Place all manifold blocks on the H-rail in accordance with the assembly
sequence.
2.
Press the manifold blocks on the H-rail until the mounting slides engage.5
Linking manifold blocks:
Fig.4
1.
Place one sealing ring each between each of the three compressed air ducts
and press the manifold blocks together.
2.
Push a connecting component onto the rail shown on both sides until it1
clicks into place.
Mounting the CPE valves:
Fig.5
1.Insert all valve spools up to the first detent.2
2.
Place a seal on every compressed air outlet.
Product specificaties
| Merk: | Festo |
| Categorie: | Niet gecategoriseerd |
| Model: | CPE18-PRSGO-2 |
Heb je hulp nodig?
Als je hulp nodig hebt met Festo CPE18-PRSGO-2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Festo
Festo NEBL-T12W4-E-2-N-LE4 Handleiding Festo VAEM-L1-S-M3-50 Handleiding Festo VAEM-L1-S-M1-25V3 Handleiding Festo DSNU-S-12-60-P-A-MQ Handleiding Festo NEBL-T12G4-E-15-N-LE4 Handleiding Festo DSNU-S-25-20-P-A-MX Handleiding Festo VABM-B10-20-G38-6-P53 Handleiding Festo DSNU-S-25-30-P-A-MX Handleiding Festo VABM-B10-30S-G12-4-P3 Handleiding Festo VABM-B10-20-G38-3-P53 Handleiding
Populair in Niet gecategoriseerd
Festo VZQA-C-M22C-15-S5S5-ALV4E-6-E Handleiding Festo SFAB-200U-HQ10-2SV-M12 Handleiding Festo DPDM-Q-6-15-P-PA Handleiding