Bekijk gratis de handleiding van Everpure Insurice Triple 7SI (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.1 sterren uit 4 reviews. Heb je een vraag over Everpure Insurice Triple 7SI of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/4
SELECTING A LOCATION
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights of the Insurice Systems
are:
Insurice Single - 7SI - 9 lbs (4.0 kg)
Insurice Twin - 7SI - 19 lbs (8.5 kg)
Insurice Triple - 7SI - 27 lbs (12 kg)
Insurice Quad - 7SI - 36 lbs (20 kg)
2. The location should allow for:
Minimum clearance of 2
1
Adequate space for “in” and “out” water line connections.
Be near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard™ Low Pressure Alarm is
used. See Step 5.
3. If used in conjunction with the Everpure SR-X Feeder, the SR-X should be mounted after the Insurice Series Filter and as
near the equipment as possible. If possible, keep at least 6" available to the left and the right of the Insurice System in the
event poor quality water conditions require the installation of the optional Everpure E-Series Prefilter.
OPERATING SPECIFICATIONS
For cold water use only.
Operating Temperature: 35 100°F (2 38°C)
Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar), non-shock
Flow Rate:
SystemReplacement CartridgeFlow RateCapacity
Insurice Single
7SI7SI3.5 gpm (13.25 Lpm)25,000 gal. (94,635 L)*
Insurice Twin
7SI7SI7.0 gpm (26.50 Lpm)50,000 gal. (189,271 L)*
Insurice Triple 7SI7SI10.5 gpm (39.75 Lpm)75,000 gal. (283,906 L)*
Insurice Quad - 7SI7SI14.0 gpm (53.00 Lpm)100,000 gal. (378,541 L)*
INSTALLATION INSTRUCTIONS
1. Use the predrilled mounting holes in the manifold bracket as guides. Mark and drill anchor holes. Mount securely. See
Figures 1 4 .
2. Shut off power to equipment.
3. Connect outlet port of the Insurice System to equipment served. Always use an NSF approved pipe dope or Teflon
®
tape at
all connections. Use a backup wrench on all fittings while connecting to avoid excessive stress on the system components.
Note: If the optional E-Series Prefilter is used, install a manual shut-off valve leading to the system for servicing.
4. Connect minimum 3/8" water line to the Insurice Single System inlet. Use a minimum 1/2" line for other systems.
Insurice Single 7SI SystemInsurice Twin 7SI SystemInsurice Triple 7SI SystemInsurice Quad 7SI System
*As tested by Everpure
FILTRATION & PROCESSING SOLUTIONS
7SI INSURICE SYSTEMS INSTRUCTION & OPERATION GUIDE
EVERPURE
®
EVERPURE
®
7SI INSURICE
®
SERIES SYSTEMS