Bekijk gratis de handleiding van Emko IPERTU Supply (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 55 mensen en kreeg gemiddeld 5.0 sterren uit 28 reviews. Heb je een vraag over Emko IPERTU Supply of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
1 ENG IPERTU-MPS060 02 V00_0323
60W Power Supply Module
General Specicaons :
* Universal Input Voltage 100-240 V (-15% .. +10%) 50/60 Hz AC
* 24VDC Adjustable Output Voltage (±%10)
* 2,5 A / 60 W @ 24 V DC
* Acve Output Led indicator
* Can be connected to other IPERTU modules over IPERTU BUS
without cable connecon (must be connected to le of the
modules connected to the IPERTU BUS)
IPERTU-MPS060- - - -00_1 00 00 00
Electrical Specicaons
Input
Input Voltage Range
100-240 VAC (-%15 + %10) 50/60 Hz
Eciency
> 84%
Inrush Current
max 33A @ 230 VAC
Leakage Current
max 2.5mA
Output
Rated Power
60W 2,5 A @ 24 VDC
Adj Voltage Range .
24 VDC (±%10) Can be adjusted with Trimpot in the given range.
Ripple
300 mVpp max
Load Regulaon
< %1,5
Line Regulaon
< %1,5
Start Up Time
1200ms/230V AC
Hold Up Time
100ms/230VAC
Protecons
Overload Protecon
% 140
Short Circuit Protect.
Auto-recovery aer error disappears.
Thermal Protecon
When the ambient temperature rises above 55 °C, the output voltage reduced depending on
ambient temperature and load current.
Operaon / Storage Environment
Operaon Temp.
- 20..+50 °C
Storage Temperature
- 30..+75 °C
Protecon Class
IP20
Polluon Degree
2
İsolation
* 3000 VAC isolaon between Input and Output
* 1500 VAC isolaon between Input and Earth
* 500 VAC isolaon between Output and Earth
Dimensions (W*H*D)
50*100*70 mm
Weight
230 gr
Indıcators
Output
Output Led is ON when the output is in rated limits.
2 ENG IPERTU-MPS060 02 V00_0323
Installaon & Wiring
* Please check all wiring prior to energizing device. In order to prevent electromagnec interference, be sure the
grounding made corrected. Connect ground terminal in the power input connector to the overall system ground. Don’t
touch any terminals aer energizing the device, in case of need to touch any terminal, de-energize the device before
connecon.
Dimensions


Product specificaties

Merk: Emko
Categorie: Niet gecategoriseerd
Model: IPERTU Supply

Heb je hulp nodig?

Als je hulp nodig hebt met Emko IPERTU Supply stel dan hieronder een vraag en andere gebruikers zullen je antwoorden