Elecom HCS-FS02 Handleiding


Bekijk gratis de handleiding van Elecom HCS-FS02 (6 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.7 sterren uit 2 reviews. Heb je een vraag over Elecom HCS-FS02 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/6
*
Press either or button to select the region number.
Body composition analyser
Manual
HCS-FS02 series
For use in Hong Kong, Singapore
and the Philippines only.
Precautions
DANGERWARNING
Never use this product with the
following medical electronic devices.
Never judge the measurement results yourself (or do such things as
evaluate measurements or base an exercise plan on this).
Weight loss and therapeutic exercise based on self-judgment may
be bad for your health. Always follow the instructions of a certified
professional.
Do not step on the edge of the analyser, jump on the analyser, or
jump up and down on the analyser. Doing so may cause you to fall
or slip, resulting in serious injury.
Do not use the analyser on a slippery surface, such as a tile surface
or wet floor. Doing so may cause you to fall or slip, resulting in
serious injury. Furthermore, water may get inside the analyser and
cause a breakdown.
Never modify, disassemble, or repair the analyser. This may cause
an unexpected accident or other trouble.
Do not mix different types of batteries together or old batteries with
fresh ones. Doing so may cause battery leakage and failure.
(1) Pacemakers and other implantable
medical electronic devices
(2) Heart-lung machines and other
artificial life-support medical
electronic devices
(3) Electrocardiographs and other
wearable medical electronic devices
This analyser passes a weak electric
current through the body and may
cause the above-mentioned devices
to malfunction, resulting in an
accident or serious injury.
Setting the region number
Specification
* Please note that all the specifications for the settings information, except 'weight', are presumptions calculated with weight
or resistance value. BMI is the calculated value.
Maximum weight measurementapproximately 150 kg
2.5 to 100 kg50 g over 100 kg100 g
2.5 to 75 kg± 100 g 75 to 100 kg± 150 g 100 to 150 kg± 300 g
weight comparison
-9.9 to 9.9 kg: 100 g *compares to the previous weight
0.1
0.1%
9 levels
9 levels
1 to 30
6 levels
0.1kg
500 to 3000kcal/day: 1kcal
5 regions
2017/1/1 to 2050/12/31
000 to 235924-hour notation
4 people
1900/1/1 to 2040/12/31
Male/ Female
100.0 to 250.0cm0.5cm
5 to 75%0.1%
BMI
body fat percentage
body fat percentage standards
skeletal muscle percentage
skeletal muscle percentage standards
visceral fat level
visceral fat level standards
bone quantity
basal metabolism
area/region
dates
time
user registration
date of birth
sex
heights
DC4.5V / dry cell AAA battery × 3
0 to 40°C0 to 90 RH
approximately 1.0 kgexcluding batteries
approximately W270 × D230 × H23 mm
AAA batteryR03× 3
Weight capacity
Weight increments
Scale unit of measurement
Settings
Power consumption
Operating temperature and humidity ranges
Weight
Dimensions
Sample batteries
Your geographical location, longitude and latitude, affects your gravity, so you need to select the
appropriate region number to get an accurate measurement.
Because this product is designed for use in Japan, specific regions are not available for every
country. This can affect your measurements by up to 100g either way. Please select region no.5 for
Hong Kong, Singapore and the Philippines(Manila).
Hold down the (power) button untill the '地域' (region) number flashes.
When you first turn on the analyser or after changing the batteries,
press the (power) button to display the region setting mode.
To change the region number, hold down the (power) button that
turns the analyser on.
Press the (setting) button. The region number will be set.
Part names
Displaypanel
Electrodes
Electrodes
Battery cover
Operation section
Battery exchange display
(Switches on when the battery must be replaced.)
Operationconfirmation display
(Switches onif an operationbutton is pressed.)
Display
section
Level display (Displays the evaluation result.)
(Low)(Normal)(High)
Power button
(Press to switch the power on or off. The power
also switches on when you step on the analyser.
In such cases, the user number is recognized
automatically.)
(Press and hold to change quickly.)
(Press and hold to
change quickly.)
(Press when measuring only your
weight, or the weight of a baby or pet.)
(Press to register, edit, or check users. Press to enter settings during
configuration. Press and hold to return to the previous setting.)
Left button(Back)
Weight mode button
Right button(forward)
Enter button
Using the analyser
Inserting the batteries
On the rear surface of the analyser, push
the battery cover in the direction of the
arrow, and then remove it.
Place the analyser on a hard flat surface, such as a wooden floor.
Do not place the analyser on any of the following surfaces. Doing so may cause errors in the
measurement values.
Insert the 3 included size AAA batteries
after checking the polarity ( / ). The
side with the spring is the negative ( )
side.
Attach the battery cover.
Placingtheanalyser
Sloped floor
Soft surface, such as a rug
Measures only your weight. For the measurement method, see the next page.
Measuring the weightofa baby or pet
Measuring onlyyour weight
Displays the difference in weight between the 1st and 2nd measurements to measure the
weight of a baby or pet. For the measurement method, see the next page.
The following 3 methods can be used to measure with this analyser.
Measuring body composition
Measure after automatic recognition of the user
The power is switched on and measurement is started by simply stepping on the analyser.
In addition, the user is recognized automatically from the registered users, and the measurement
results are recorded. (Limited to when the user number has been specified and measurement
has been performed at least once in the past.)
Step on while the power is offMeasuringUser number is displayed
Measure after specifying the user number
Measure using Guest mode
Specify the number of a registered user, and then measure. The user is matched reliably with
their registered data (more so than with automatic user recognition), and then the measurement
results are displayed. For the user registration and measurement methods, see the next page.
An unregistered user can be measured. The measurement values cannot be recorded. For the
measurement method, see the next page.
The analyser was stored standing up
The analyser was picked up and moved
The automatic 0.00 kg calibration and
correction function
When the measurement values are obviously incorrect, performthe following procedure, and then measure again.
Press the Enter button (
).
体重
Make sure that0.00kg” is
displayed.
Press the Powerbutton ( )
to switch off the power.
Place the analyser on a hardat
surface.
Make sure that is displayed.
Do not place anything on theanalys
er
or applyweight to the analyser while
is displayed.
The power is switched on and measurement is started by
simply stepping on the analyser. Accordingly, the analyser is
calibrated automatically to 0.00 kg periodically while the power
is switched off. However, calibration may not be performed
correctly in the situations listed below. Before using the
analyser for measurement, always place the analyser on a
hard surface with nothing on top of the analyser, and then
pres
s either the Power button ( ) or Enter button (
).
The analyser was stored with something on top of the
analyser
Presseither the Power button ( )
orEnter button ( ).