Elecom DE-NESTGPM1BK Handleiding

Elecom Pomp DE-NESTGPM1BK

Bekijk gratis de handleiding van Elecom DE-NESTGPM1BK (7 pagina’s), behorend tot de categorie Pomp. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.8 sterren uit 2 reviews. Heb je een vraag over Elecom DE-NESTGPM1BK of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/7
25 mm (0.98 in.)
Package contentsHow to use (continued)How to use (continued)
Maintenance
Specifications
Main unit
∙ Main unit
∙ Eight types of air nozzles
∙ Two inflation aids
∙ Battery connector
∙ Drawstring bag
∙ Fire bellows
(Aheatshield(M)ispre-attached.)
∙ Heat shield (L)
*The NESTOUT outdoor battery is not
included. Please acquire a NESTOUT
outdoor battery separately.
How to connect the battery and the main unit
Names of individual components
How to use
The valve dimensions listed in the table below are approximate. If there is any gap, try a dierent air nozzle.
Depending on the valve shape, none of the air nozzles may fit perfectly. In that case, use the air nozzle
that is closest in size and hold it in place by hand during use.
*1 When using the 5000mAh Power Bank, the operating time depends on the airflow setting. Operating time may be shorter due to
battery degradation or ambient temperature.
*2 This product was measured according to test methods conforming to ISO 5801 and JIS B 8330 standards.
*3 Even within the compatible diameter range, this product may not be usable with certain air mattress valve shapes.
Compatibility with all models is not guaranteed.
*4 Not including the battery and the air nozzle.
*5 The fire bellows is included with DE-NESTGPMF1 only.
Verify the package to ensure all contents are
present prior to using the product. Every eort
has been made to ensure proper packaging,
however in the event any shortage or damage
is discovered, contact the retailer where the
product was purchased.
Power switch
Air outletAir inlet
USB Type-C
®
plug
Battery lock release button
(Located on both left
and right sides)
Battery connector
Drawstring bag
Fire bellows
Heat shield (L)
Each of the air nozzles is marked with a number (1 to 6) or a letter (A or B).
Choose the one that fits the valve type and shape of your air mattress or other inflatable.
Rotating typeOpening/Closing typeFloat type
A type where the cap is
rotated to let air in or out
A type where the cap is
opened to let air in or out
A small type where the nozzle portion
is pulled out to let air in or out
Compatible valve diameters (Outside diameters)
回転タイプ回転タイプ回転タイプRotating type
Projection
Compatible valve diameters (Inside diameters)
A type where the inside of the valve is connected to the cap
The lower section may not be used with valves with a check valve.
回転タイプOpening/Closing type
Notch
Strap
Float type
Use a combination of the air nozzle A, air nozzle B, and air nozzle 1.
*Please pay attention to the orientation of the battery connector.
The side without the indent is the side that connects to the battery.
*Screw on the battery connector tightly until there is no gap.
*It may be a little dicult to screw on the battery connector. This is normal.
Open the cap of the NESTOUT outdoor battery and attach the battery
connector to it.
*When it is inserted until there is no gap, the lock will engage.
If the power LED on the NESTOUT outdoor battery is o, press the
power button on the NESTOUT outdoor battery to turn it on.
To remove the main unit from the NESTOUT outdoor battery, press
the battery lock release buttons on both the left and right sides to
release the lock beforehand.
Power LED
Battery lock
release button
For the position and operation method of the air mattress valve you are using, please refer to the
instruction manual of each product.
If the valve has a check valve, air may be dicult to enter depending on
the stiness of the check valve.
In that case, use a valve without a check valve, or insert the inflation aid
into the check valve before attaching the air nozzle.
Please refer to “
How to select air nozzles” to choose the appropriate
air nozzle.
For the position and operation method of the air mattress valve you are using, please refer to the
instruction manual of each product.
If the valve has a check valve, air may be dicult to enter depending on
the stiness of the check valve.
In that case, use a valve without a check valve, or insert the inflation aid
into the check valve before attaching the air nozzle.
Please refer to “ How to select air nozzles” to choose the appropriate
air nozzle.
Depending on the structure of the air mattress, the air passage inside the air mattress may become
blocked, preventing air from escaping. In that case, use the pump to remove the air while widening
the air passage or folding the mattress.
The nozzle of the fire bellows is telescopic, reducing fatigue when building a fire.
The shield protects your hand and the battery from heat and sparks, allowing you to build a fire safely.
When using the product with the NESTOUT outdoor battery of 2-port type, replace its shield with
the heat shield (L).
IP67 WATERPROOF / DUSTPROOF
SHOCK RESISTANCE
IP67 WATERPROOF / DUSTPROOF
SHOCK RESISTANCE
IP67 WATERPROOF / DUSTPROOF
SHOCK RESISTANCE
• 1-port type• 2-port type
Use the heat shield (M).Use the heat shield (L).
While turning it, hold the
opposite side to prevent
the nut from falling.
For safety, be sure to extend the telescopic nozzle when using the product, and
do not use it while the main unit and the battery are near fire.
Do not bring the product close to fire while the power is OFF and no air is being
sent from the main unit. The telescopic nozzle may become extremely hot.
The telescopic nozzle may be hot while it is near fire and immediately afterward. Be
careful enough not to burn yourself when touching it directly.
Be sure to remove the NESTOUT outdoor battery before doing maintenance
procedures on this product.
It is very dangerous if the power is accidentally turned on and the motor rotates.
Never wash the main unit with water. Do not use benzene, paint thinner, alcohol or
hot water.
During maintenance, wipe the product with a soft, dry cloth. If the product is badly soiled, wipe it
with a cloth that has been soaked in water or diluted neutral detergent and wrung dry.
Check that the power switch on the main unit is set to 0 (O).
Check the orientation of the USB Type-C plug on this product and
the USB Type-C port on the NESTOUT outdoor battery when
connecting.
When inflating
Open the valve of the air mattress so that air can enter.
Attach the air nozzle to the valve of the air mattress.
Attach the pump’s air outlet to the air nozzle.
When you slide the power switch on the main unit to 1 (Light)
or 2 (Strong) and turn it on, inflation will start.
When deflating
Open the valve of the air mattress so that air can enter.
Attach the air nozzle to the valve of the air mattress.
Attach the pump’s air inlet to the air nozzle.
When you slide the power switch on the main unit to 1 (Light)
or 2 (Strong) and turn it on, deflation will start.
Fire bellows (Only for DE-NESTGPMF1)
Remove the screw.Remove the screw.
Remove the heat shield (M).
Attach the heat shield (L).
Tighten the screw.
How to select air nozzles
A type that is large and has four projections on the cap
ENGLISH
Air Pump
Manual
Eight types of air nozzles
Inflation aid
Attach the air nozzle over the cap.
Use a combination of the air nozzle 3
and the air nozzle 5.
Use the lower section of the air nozzle 4.
Align the notch in the ring with the direction of the cap’s strap.
Air outlet
Air inlet
Air nozzle3456
Appearance
Outside
diameter
14 to 17 mm
(0.55 to 0.67 in.)
17 to 20 mm
(0.67 to 0.79 in.)
20 to 22 mm
(0.79 to 0.87 in.)
22 to 26 mm
(0.87 to 1.02 in.)
AB
6 to 9 mm
(0.24 to 0.36 in.)
9 to 13 mm
(0.36 to 0.51 in.)
Power supply (sold separately)NESTOUT outdoor battery
Estimated operating time from afull charge *1Approx.40 to 80 min
Maximum staticpressure *2Approx. 3.0 kPa (0.44 psi)
Maximum air volume*2Approx. 160 L/min (42.3 gal/min)
Air volume mode2 modes (strong, light)
Compatible valve
diameter *3
Rotating typeOutside diameter:14 to 26 mm (0.55 to 1.02 in.)
Opening/Closing typeInsidediameter: 13 to 32 mm (0.51 to 1.26 in.)
Float typeInsidediameter: 6 to 13 mm (0.23 to 0.51 in.)
Rated voltageDC5 V
Current consumption3 A
External
dimensions *4
Pump
Approx. W46 × D64 ×H44 mm
(W1.8 × D2.5 × H1.7 in.)
With fire bellows *5
Approx. W93 × D218 to 705 × H167 mm
(W3.7 × D8.6 to 27.8 × H6.6 in.)
Weight *4
PumpApprox.84 g (2.96 oz)
With fire bellows *5Approx.150 g (5.29 oz)
Air nozzle123456
Appearance
Upper section
13 to 15 mm
(0.51 to 0.59 in.)
15 to 18 mm
(0.59 to 0.71 in.)
18 to 22 mm
(0.71 to 0.87 in.)
22 to 25 mm
(0.87 to 0.98 in.)
25 to 29 mm
(0.98 to 1.14 in.)
29 to 32 mm
(1.14 to 1.26 in.)
Lower section
17 to 20 mm
(0.67 to 0.79 in.)
20 to 22 mm
(0.79 to 0.87 in.)
23 to 26 mm
(0.91 to 1.02 in.)
26 to 28 mm
(1.02 to 1.10 in.)
29 to 32 mm
(1.14 to 1.26 in.)
For screw
type only
DE-NESTGPM series
Model: DE-NESTGPM, DE-NESTGPM1BK, DE-NESTGPM1BE, DE-NESTGPMF1BK, DE-NESTGPMF1BE
*Only for DE-NESTGPMF1
*Only for DE-NESTGPMF1
0: O
1: Light
2: Strong
Telescopic nozzle
Heat shield (M)
Upper
section
Lower
section
Inflation aid
Check valve
Insert the inflation aid
into the air nozzle.
Insert it into the gap of
the check valve to allow
air to enter easily.
Inflation aid
Check valve
Insert the inflation aid
into the air nozzle.
Insert it into the gap of
the check valve to allow
air to escape.

Beoordeel deze handleiding

4.8/5 (2 Beoordelingen)

Product specificaties

Merk: Elecom
Categorie: Pomp
Model: DE-NESTGPM1BK

Heb je hulp nodig?

Als je hulp nodig hebt met Elecom DE-NESTGPM1BK stel dan hieronder een vraag en andere gebruikers zullen je antwoorden