ECLER TECHNICAL DATA SHEET
1/6
HUB1408
DIGITAL MATRIXES
8 outputs digital zoner with DSP
PRODUCT OVERVIEW
HUB1 is a digital zone manager with inputs and 8 outputs. It has the HANGAR embedded web-server 408 14
application (control from standard web browser in Windows / MacOS, etc.) for its configuration; remote control from
physical wall installation panels, call (paging) stations and applications for mobile devices (Android, iOS). Includes DSP
with specific functions for both inputs and outputs.
HUB Series offers multiple possibilities, being intuitive and easy to configure. From the least experienced user to the
most expert, you can set up a professional audio installation in a matter of minutes (Plug & Play). It is the perfect
solution for any type of sound that requires managing and controlling different zones.
KEY FEATURES
• 14 inputs, 8 outputs digital zoner with integrated DSP
• Easy programming and control by embedded web
application, HANGAR, and standard web browser
• Control from the front panel and user remote control by:
- eMCONTROL1 wall panels (up to 8)
- eMPAGE paging consoles (up to 2)
- Ecler pilot application, compatible with Android and iOS:
control graphic panels set to user needs (pilot panels)
- -NET protocol (RS-232 interface with DB9 connector) TP
for control and integrating with third party systems
• Control available, by zone (output): selection of audio
source (input), volume adjustment and MUTE, 3 band tone
adjustment and general volume
• Four priority levels, ducker/pager functions
• Available DSP: frequency shifter, link stereo, delay,
crossover filters, 8-band graphic EQ, compressor/limiter
and much more
• Predefined setups for a quick installation (plug and play)
• MUTE port can be activated by closing the external dry
contact, affecting programmed outputs to this effect.
APPLICATIONS
• Commercial
• Hospitality
• Education
• Corporate
• Sports and wellness
ACCESSORIES & COMPATIBLE DEVICES
• eMPAGE
• eMCONTROL1
eMPAGE
eMCONTROL1

ECLER TECHNICAL DATA SHEET
2/6
TECHNICAL SPECIFICATIONS
HUB1 408
DIGITAL
DSP
CPU
Floating point 64bit 32/
Sampling rate
48 kHz
Latency
<1.5 ms.
Converters
Resolution
24 bit, AKM
Dynamic range
AD:111dB, DA: 115dB
ANALOGUE
Input 1, 2 (Line)
Sensitivity
+5 / -15dBV External potentiometer adjust ment
Impedance
>13k
Input headroom
12dBV
Connector
RCA female with Euroblock stack
Type
Unbalanced
Input 3, 4, 5 ,6 (Mic/Line)
Sensitivity
+0 / -50dBV External potentiometer adjust ment
Impedance
>24k electronically balanced
Input headroom
12dBV
Connector
Euroblock (Symmetrical)
Type
Balanced
Pagers
Input 5 and 6 (by RJ45 connector)
Phantom
+48VDC (rear panel switch)
CMRR
>60dB (20Hz - 20kHz)
Input 7 4 (Remote Input) to 1
Sensitivity
0dBV without adjustment
Impedance
>24k electronically balanced
Input headroom
12dBV
Connector
RJ45 Connector
Type
Balanced
CMRR
>60dB (20Hz - 20kHz)
Outputs 1 to 8 (Line)
Max output level
12dBV
Connector
Euroblock 3-pin
Type
Balanced
Headphones output
Selectable output
From Out1 to Out8
Power
>200mW 200 – Ω
Connector
Mini-Jack 3,5mm
General
External mute
Normally open. Assignable to any output zone
Frequency response
<10Hz ~ 20kHz (+0dB / -0.5dB)
Output noise floor (FFT)
>110dB (from 20Hz to 20kHz)
THD + Noise)
< 0.005% (1kHz, 1Vrms)
Crosstalk
>90dB, 20Hz - 20kHz
CMRR
>60 dB Typical
Flatness
Better than ±0.1dB

ECLER TECHNICAL DATA SHEET
3/6
PROCESSING
Input level (x14)
Volume
From Off to 0 dB
Mute
On-Off
Metering
Vumeter post fader
Stereo
On-Off (Inputs 3 to 6)
Polarity
On-Off
High pass filter
50Hz to 150Hz (Inputs 3 to 6)
Frequency shifter
On-Off ; 5Hz (Inputs 3 to 6)
Noise gate (x4)
Inputs
Input 3 to 6, Bypass ON - OFF
Threshold
From -80dBV to +12dBV
Depth
From 0 dB to 80 dB
Attack
From 0.1ms to 500ms
Hold
From 10ms to 3000ms
Release
From 10ms to 1000ms
Input EQ (x14)
Type
Baxandall 3 way EQ
Gain
-10dB ~ +10dB in 0.1dB steps
Frequency
Low 200Hz Mid 1kHz High 6.3kHz
Output level 8)(x
Volume
From Off to 0 dB
Mute
On-Off
Metering
Vumeter post fader
Stereo
On-Off
Polarity
On-Off
Output EQ (x8)
Type
Baxandall 3 way EQ
Gain
-10dB ~ +10dB in 0.1dB steps
Frequency
Low 200Hz Mid 1kHz High 6.3kHz
Output graphic EQ (x8)
Type
8-Band Graphic EQ
Gain
-10dB ~ +10dB in 0.1dB steps
Frequency
63Hz, 125Hz, 250Hz, 500Hz, 1kHz, 2kHz, 4kHz, 8kHz
Output compressor (x8)
Bypass
On-Off
Mode
Compressor / Limiter
Threshold
-36 dB to +12 dB
Ratio
1 to 100
Knee
Soft / Hard
Attack
0.1ms to 500ms
Release
10ms to 1000ms
Make-up gain
0 dB to 10 dB
Output delay (x8)
Outputs
1 to 8
Bypass
On-Off
Delay
0 to 300ms
Unit
ms, meters, feet
Product specificaties
Merk: | Ecler |
Categorie: | Niet gecategoriseerd |
Model: | HUB1408 |
Heb je hulp nodig?
Als je hulp nodig hebt met Ecler HUB1408 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Ecler

11 Juni 2025

11 Juni 2025

11 Juni 2025

4 Juni 2025

3 Juni 2025

3 Juni 2025

3 Juni 2025

3 Juni 2025

30 Januari 2025

3 November 2024
Handleiding Niet gecategoriseerd
- Niet gecategoriseerd Dash
- Niet gecategoriseerd Aim TTi
- Niet gecategoriseerd Mercusys
- Niet gecategoriseerd Endress
- Niet gecategoriseerd LYYT
- Niet gecategoriseerd Entes
- Niet gecategoriseerd Wegman
- Niet gecategoriseerd Plant Craft
- Niet gecategoriseerd Williams Sound
- Niet gecategoriseerd Tower
- Niet gecategoriseerd Novy
- Niet gecategoriseerd Pippi
- Niet gecategoriseerd Wet Sounds
- Niet gecategoriseerd Ravanson
- Niet gecategoriseerd Vurkcy
Nieuwste handleidingen voor Niet gecategoriseerd

12 Juni 2025

12 Juni 2025

12 Juni 2025

11 Juni 2025

11 Juni 2025

11 Juni 2025

11 Juni 2025

11 Juni 2025

11 Juni 2025

11 Juni 2025