SDM230A/D/DR/BI
Single Phase Two Wires Din Rail Energy Meter
Technical Data
Safety Instructions
Information for your own safety
This manual does not contain all of the safety measures for operation of
and local code requirements or regulations may necessitate further
measures. However,it does contain information which must be read
for your personal safety and to avoid material damages.This information
is highlighted by a warning triangle and is represented as follows,
depending on the degree of potential danger.
Warning
This means that failure to observe the instruction can result in
death, serious injury or considerable material damage.
Caution
This means hazard of electric shock and failure to take the
necessary safety precautions will result in death,serious injury
or considerable material damage.
Qualified personnel
Operation of the equipment (module, device) described in this manual
may only be performed by quali ed personnel. Quali ed personnel in
this manual means person who are authorized to commission, start
up, ground and label devices,systems and circuits according to safety
and Regulatory standards.
Use for the intended purpose
The equipment (device, module) may only be used for the application
speci ed in the catalogue and the user manual,and only be connected
with devices and components recommended and approved by EASTRON.
Proper handling
The prerequisites for perfect, reliable operation of the product are proper
transport, proper storage, installation and assembly, as well as proper
operation and maintenance. When operating electrical equipment, certain
parts of this equipment automatically carry dangerous voltages. Improper
handling can therefore result in serious injuries or material damage.
Use only insulating tools.
Do not connect while circuit is live (hot).
Place the meter only in dry surroundings.
Do not mount the meter in an explosive area or expose the meter
to dust, mildew and insects.
Make sure the used wires are suitable for the maximum current of
this meter.
Make sure the AC wires are connected correctly before activating
the current/voltage to the meter.
Do not touch the meter connecting clamps directly with your bare
hands, with metal, blank wire or other material as you may get an
electrical shock.
Make sure the protection cover is placed after installation.
Installation, maintenance and reparation should only be done by
quali ed personnel.
Never break the seals and open the front cover as this might in uence
the functionality of the meter, and will avoid any warranty.
Do not drop, or allow physical impact to the meter as there are high
precision components inside that may break.
Performance criteria
Operating humidity
Storage humidity
Operating temperature
Storage temperature
Active energy accuracy
Ingress protection
Insulating encased meter of
protective class
Warm up time
Mechanical environment
Electromagnetic environment
Degree of pollution
≤ 90%, non-condensing
≤ 95%, non-condensing
-25°C - +55°C
-40°C - +70°C
Class B EN50470-1/3
Class 1 IEC62053-21
IP51(in door)
II
5s
M1
E2
2
Speci cations
Nominal voltage(Un)
Operational voltage
Insulation capabilities
- AC voltage withstand
- Impulse voltage withstand
Basic current (Ib)
Maximum rated current (Imax)
Operational current range
Over current withstand
Operational frequency range
Internal power consumption
Test output ash rate (PULSE LED)
Test pulse output rate
Max. reading
230V AC
80%~120% Un
4KV for 1 minute
6KV-1.2µS
10A
100A
0.4% Ib~Imax
30Imax for 0.01s
50Hz (MID)
50 60Hz(non-MID)/
≤ 2W/10VA
1000imp/kWh
1000imp/kWh
99999.9 (SDM230D)
999999.9(SDM230A/DR/Bi)
Introduction
Z
Z
Z
ZZHE
HE
HE
HEHEJ
J
J
JJIA
IA
IA
IAIAN
N
N
NNG
G
G
G G EA
EA
EA
EAEAS
S
S
SSTR
TR
TR
TRTRO
O
O
OON
N
N
N N EL
EL
EL
ELELE
E
E
EECT
CT
CT
CTCTR
R
R
RRO
O
O
OONI
NI
NI
NINIC
C
C
C C CO
CO
CO
COCO., LTD.
., LTD.
., LTD.
., LTD.., LTD.
Add: No.1369 Chengnan Road, Nanhu, Jiaxing, Zhejiang, 314001, China
Tel: +86-573-83698881 Fax: +86-573-83698883
Email:sales@eastrongroup.com Web:www.eastron.com.cn www.eastrongroup.com
Dimensions
The SDM230* series are single phase two wires energy meters “with a
white back-lighted LCD screen for prefect reading”. They are used to
measure single phase energy in residential and commercial applications.
The series contains 4 models: SDM230A, SDM230D,
SDM230DR,SDM230Bi
SDM230A : 1P2W energy meter with analog register
SDM230D : 1P2W energy meter with LCD display
SDM230DR: 1P2W energy meter with resettable partial energy
SDM230Bi : 1P2W energy meter with bi-directional measurement
SDM230DR and SDM230Bi have been MID approved. They measures
both active energy (kWh) and power (W). There are two buttons on the
front panel, one is used to scroll the info pages, another to reset partial
energy information. All models has a pulse output, which is passive type.
The constant is 1000imp/kWh.
Height
Width
Depth
100mm
36mm
63mm
36m m
63m m
100mm
35m m
45mm
Minimum rated current(Imin) 0.5A
5
6
7
8
9
Operation
Wiring
Z
Z
Z
ZZH
H
H
HHE
E
E
EEJ
J
J
JJI
I
I
IIA
A
A
AAN
N
N
NNG
G
G
G G E
E
E
EEA
A
A
AAS
S
S
SST
T
T
TTR
R
R
RRO
O
O
OON
N
N
N N E
E
E
EEL
L
L
LLE
E
E
EEC
C
C
CCT
T
T
TTR
R
R
RRO
O
O
OON
N
N
NNI
I
I
IIC
C
C
C C C
C
C
CCO.,
O.,
O.,
O., O., L
L
L
LLT
T
T
TTD.
D.
D.
D.D.
Add: No.1369 Chengnan Road, Nanhu, Jiaxing, Zhejiang, 314001, China
Tel: +86-573-83698881 Fax: +86-573-83698883
Email:sales@eastrongroup.com Web:www.eastron.com.cn www.eastrongroup.com
Installation Diagram
We Zhejiang Eastron Electronic Co.,ltd.
Declare under our sole responsibility as manufacturer that the single phase
active import/export (kWh) indoor electricity meter SDM230*
correspond to the production model described in the EU-type examination
certi cate and to the requirements of the Directive 2014/32/E typeU .
Examination Certi cate NO.0120/ 0206.SGS
Identi cation Number of the NB0598.
Conformity Declaration
(MID version meters only)
Both SDM230DR and SDM230Bi provide a function of resettable energy.
User can press the right button for 3 seconds to reset the partial
energy.
Resettable Energy
N-in
N-out
L-out
L-in
3
4
1
2
Display info
SDM230A, equipped with a 6+1 register counter, measures and displays
active energy (kWh).
SDM230D, equipped with a LCD display, measures and displays active
energy (kWh). The initial reading starts from 0000.00 (4+2) , once it is go
up to 9999.99, the reading will change to 00000.0 (5+1). The Max. reading
is 99999.9kWh.
SDM230DR with a white backlit LCD screen for perfect reading is used to
measure single phase energy (kWh) and power (W). The unit provides
also a resettable partial energy.
SDM230Bi, equipped with white backlit LCD, the unit measures and
displays bi-direction active energy (kWh) and power (W). Resettable
partial energy function is also available.
Buttons
There are two buttons on the front panel of SDM230DR and SDM230Bi:
Scroll display
SDM230DR Information Pages:
0
This button is used to scroll the information pages.
This button is used to reset the partial energy information.
SDM230Bi Information Pages:
Initialization display
When SDM230DR and SDM230Bi is powered on, it will initialize and
do self-checking:
Full Screen
Software Version Default Page
0
SDM230A/D
7:
8:
+
SDM230DR/Bi
8:
9:
10:
+
COM
1
2
+
7
8
9
10
DH-SMS-0239
DIN Rail
35mm
Pulse
Load
0.5~1.5mm²
4~25mm²
0.2Nm
2.5Nm
Terminals
X
X
X
XX
Terminals Capacity and Screw Torque


Product specificaties

Merk: Eastron
Categorie: Meetapparatuur
Model: SDM230A

Heb je hulp nodig?

Als je hulp nodig hebt met Eastron SDM230A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden