Bekijk gratis de handleiding van Dormakaba RCI VR166 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 18 mensen en kreeg gemiddeld 4.3 sterren uit 2 reviews. Heb je een vraag over Dormakaba RCI VR166 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

INSTALLATION
RCI VR166/VR166LMKM
SURFACE MOUNTED VERTICAL ROD STRIKE
© 2018 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.comISVR166R12-18TG
Fail Locked = Fail Secure = FL AC = Alternating Current DC = Direct Current
Intermittent Duty = Energized less than 1 minute with 1:5 duty ratio
Continuous Duty = Energized 1 minute or more
Important: Adjust strike as indicated in steps 9 thru 12 to ensure
proper functionality. Ensure the exit device functions as intended for
life safety concerns by verifying electric strike and exit device compatibility.
Maximum latch projection is essential to obtain full engagement.
This product is Fail Secure only.
The local Authority Having Jurisdiction shall be consulted with regard to the use
of selected panic hardware to ensure emergency exit from the secured area.
Installations of this Vertical Rod strike qualify as “Indoor Use Only”
when not continuously exposed to an outdoor environment.
MODEVOLTAGECURRENTDUTYOHMSPEAK AMPS
Fail Locked12VACIntermittent0.1252
Fail Locked12VDCContinuous0.2152
Fail Locked24VACIntermittent0.2752
Fail Locked24VDCContinuous0.10208
UL 294 Performance Ratings:
Access Control Line Security : Level I
Destructive Attack : Level I
Endurance : Level IV
Standby Power : Level I
Catalog Specifications
Wiring Instructions
Use 12VDC wire harness for 12VDC or 12-24VAC input power.
Use 24VDC wire harness for 24VDC input power only.
Attach the red wire to (+) positive of the power supply.
Attach the black wire to the (-) negative of the power supply.
If using AC power, polarity is not observed.
Note:overheated or burnt coils caused by incorrect input voltage/wire harness
combinations will not be covered under warranty.
Electrical Latch & Keeper Monitor Specifications:
• SPDT switch, 0.1A 24VDC resistive load for LM latch monitor
• SPDT switch, 1A 12VDC resistive load for KM keeper monitor
Note: Contacts identified on the harness sleeve are indicated with the keeper in a closed
and locked condition, with no latch present
Horizontal
adjustment
mounting holes
Fig. 1
Lock down clamp
Product specificaties
| Merk: | Dormakaba |
| Categorie: | Niet gecategoriseerd |
| Model: | RCI VR166 |
Heb je hulp nodig?
Als je hulp nodig hebt met Dormakaba RCI VR166 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Dormakaba
19 September 2023
19 September 2023
19 September 2023
19 September 2023
9 Juli 2023
9 Juli 2023
9 Juli 2023
9 Juli 2023
9 Juli 2023
9 Juli 2023
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026
10 Maart 2026