Dormakaba RCI 0161 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dormakaba RCI 0161 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 18 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
INSTALLATION
RCI 0161
RIM STRIKE
Š 2019 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.comIS0161
PCN17032
R08-19GR
Exit
Device
Door
Edge
R
c
LA
B
3/4"
Important:
The RCI 0161 Electric Strike is never to be used
as a door stop. Please install stops on the frame
in appropriate locations. Ensure the exit device
functions as intended for life safety concerns by
verifying electric strike and exit device compatibility.
Maximum latch projection is essential to obtain full
holding force.
Note:
Whether this is a new install or retrofit, it is important
that the latch body is at least 3/16 away from the "
strike face. This gap is important for optimum strike
function.
Fig. 1
NOTE: Do not scale
specifications subject to
change without notice.
Installation Instructions
1. Determine the horizontal center line “A” of the
Pullman Latch on the exit device, and transfer to
frame stop. (See Fig. 1)
2. Determine the vertical center line “B” for the
Electric Strike by adding 3/4 to dimension “R”. "
(S ee Fig. 1)
Measure from the push side of the door to mark
“B” on the frame stop. Remember to subtract the
thickness of any silencers or weather stripping.
3. Prepare door jamb as per template. (See Fig. 2)
Lock Down Holes
Horizontal
Adjustment
Mounting Slotted
Holes Installations of this RIM strike qualify as “Indoor Use
Only” when not continuously exposed to an outdoor
environment.
Š 2019 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
Frame Prep Template
M
M
O
P
Q
K
KA
B
R + 3/4"
(-Silencer thickness)
C
For future maintenance alignment, loosen the two insert
screws on the back of the faceplate and move the insert
horizontally across the furrows as shown (See Fig. 3).
Re-tighten when in correct position.
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC mm
A
Horizontal center line of Pullman Latch
B
Vertical center line of 0161
C
1-5/8 1.625 41.3
K
4-1/8 4.125 105
M
1/4 - 20 Tap
O
5/16 .312 8
P
2-1/2 2.5 63
Q
1-3/8 1.375 35
Fig. 3
4. Ensure that strike insert is in the center most position on the faceplate prior to installation.
This allows for maximum adjustability when installation is complete. (See Fig. 3)
5. Connect wires from power source to terminal screws on strike (not polarity sensitive).
6. Using slotted holes in faceplate, install electric strike with two of the 1
⁄4 - 20 x 1”, socket head cap
screws provided.
7. Align strike using slotted mounting holes so that the atch engages when door is closed. Pullman L
If necessary, loosen the insert screws on the back of the faceplate and move the insert horizontally
across the furrows as shown in Fig. 3.
Re-tighten adjusted screws.
Important: Be sure exit device dead latching functions properly when door is closed before
proceeding to step 8.
8. Mark, drill and tap for the lock down screws.
Secure final location with two of the 1⁄4 - 20 x 1”, socket head cap screws provided.
Fig. 2


Product specificaties

Merk: Dormakaba
Categorie: Niet gecategoriseerd
Model: RCI 0161

Heb je hulp nodig?

Als je hulp nodig hebt met Dormakaba RCI 0161 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dormakaba

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd