Dormakaba ES96 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Dormakaba ES96 (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 17 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
ISES96F
08281280
PCN2007
R09-20GR
I N S TA L L AT I O N S
E S 9 6 F
Electric Strikes
© 2020 dormakaba USA Inc
DORMA DRIVE, DRAWER AC, REAMSTOWN, PA 17567 PHONE: (800) 523-8483 (717) 336-3881 FAX: (717) 336-2106
EMAIL: archdw.us@dormakaba.com dormakaba.us WEBSITE:
Standard Parts:
Insert
Deadbolt Keeper
Deadbolt Plug
Deadlatch Ramp (Auxiliary Bolt Bracket)
Keeper Sliding Shims: 1/16" (1.5mm) and 1/8" (3.0mm)
A Centerline Latch Faceplate and an Offset Latch Faceplate are
provided. Both are: 4-7/8" x 1-1/4" (123.8mm x 31.8mm)
Trim Plate
12VDC or 12 to 24VAC Cable Connector
24VDC Cable Connector
Anti-Tamper Security Screws (2x 12-24) and Bit
Mounting Tab Kit (2x tabs, 4x shims and 5x 12-24 screws)
Inductive Kickback Suppressor - MOV
Red Black
+-
+-
Red Black
24VDC
Terminal
12VDC
12-24VAC
Terminal
NO
NC
C
Latch
Monitor
Optional LM
Wiring the ES96F Series Electric Strike
Wiring Instructions
Use the appropriate wire harness supplied.
12V for 12VDC & 12-24VAC*
24V for 24VDC only
Attach the red wire to (+) positive of the power supply.
Attach the black wire to the (–) negative of the power supply.
If using AC power, polarity is not observed.
To meet BHMA A156.31, install the MOV provided across the positive
and negative wires or terminals of the harness. The MOV is not polarity
sensitive.
NOTE: If a suppression diode is required for access control,
observe proper polarity.
Latch Monitor Wires
Black = Common (C)
Blue = Normally Closed (NC)
Orange = Normally Open (NO)
The ES96F fail secure locking mechanism shall only be installed where allowed by the local authority having jurisdiction and shall not
impair the operation of the panic hardware or intended operation of the emergency exit.
Model ES96F must be connected to a compatible UL Listed Burglary or Access Control Power Supply.
Accessories:
96LM Latch Monitor : 08116660
UL 294 Performance Ratings:
Access Control Line Security : Level I
Destructive Attack : Level I
Endurance : Level IV
Standby Power : Level I
2
Trim Plate: This can be used in
case the frame cutout is bigger
than required.
Bend tabs to
grip frame
Deadbolt Plug: If the lock set
doesn’t have a deadbolt, then
replace deadbolt keeper with
deadbolt plug.
NOTE: Deadlatch Ramp also acts
as a Keeper stop, so don’t forget to
insert it for centerline cylindrical lock
applications.
Deadbolt
Plug
Cylindrical
Horizontal Adjustment: If there is play
in the door when closed; the keeper
shims may be used to minimize play.
Keeper
Sliding Shim
1. Place the folded template square to the frame. Horizontally align
holes marked on the template with the mounting holes in frame.
2. Peel adhesive backing and paste the folded template square to the
frame.
3. Carefully cut the frame inside the un-shaded area marked on the
template. Install strike per installation instructions ISF2
For Cutting ANSI Prep Frames
NOTE: Speciîšżcations subject to change without notice.
* Dimension F is measured from face of mounting tab to face of
frame.
** Dimension X on the drawing is determined by the vertical
centerline of the door. If the latch incorporates a deadlocking pin
additional steps will be necessary to ensure proper operation of the
deadlocking pin. Measure the thickness of the deadlocking pin and
add this thickness to Dimension X to relocate the vertical centerline an
appropriate distance on the frame.
z
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
A 1-1/4” 1.250 31.75
B 4-7/8” 4.875 123.83
C 3-3/8” 3.375 85.73
DF + 1-7/16” F + 1.438 F + 36.51
E 3/8” 0.375 9.53
F 3/16”* 0.188* 4.76*
G 1-11/16” 1.688 42.86
X Vertical Centre Line of Door
Lock and Mounting Face Plate**
K 4-1/8” 4.125 104.78
M 12-24 N/A N/A
Z 3-5/16” 3.315 84.14
Frame Prep Dimensions
Special Features
3
1. Mark the horizontal Lock Body Centerline on the door.
Close the door and transfer the Lock Body Centerline to the
frame.
If the door isn’t ush to the frame in the closed position, mark
the depth of the closed door on the frame. Measure half of the
door thickness back toward the door stop and mark the vertical
Door Centerline on the frame.
2. Horizontally align the proper Template Lock Centerline with
the Lock Body Centerline marked on the frame. Peel adhesive
backing and paste the folded template square to the frame.
If the door isn’t ush to the frame when closed, tear the tem-
plate at the fold line. Align the faceplate portion vertically with
the Door Centerline and match the template Lock Centerline
with the Lock Body Centerline marked on the frame.
Carefully paste the front portion of the template on face of
frame to align with the faceplate portion.
3. Carefully cut the frame inside the un-shaded area marked on
the template.
Follow Mounting Tab Installation Instructions.
For Cutting Frames without ANSI Prep
Frame
Self-Adhesive
Mounting Shim
(4 incl.)
Mounting bTa
(2 incl.)
12-24 Machine
Screws (2 per tab)
a) Fasten the mounting tabs to the faceplate of the strike, selecting the
appropriate shims for the installation.
b) Using the assembled strike and tabs as a template, place against the
frame and mark the mounting hole locations. Remove and drill a 3/16”
hole in frame for each mounting tab and countersink the frame.
c) Remove the tabs from the faceplate and install in the frame using the
12-24 x 3/8” machine screws supplied. Tabs are plated and drilled and
tapped for this purpose.
d) Install strike per page 4 mounting instructions.


Product specificaties

Merk: Dormakaba
Categorie: Niet gecategoriseerd
Model: ES96

Heb je hulp nodig?

Als je hulp nodig hebt met Dormakaba ES96 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dormakaba

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd