Before installing the pump, remember the following:
1. Vacuum pump can be installed horizontally (either right-side
up A
or upside downB
), or vertically with inlet at bottomC
.
2. The pump can be mounted from 2 to 15 feet from the vacuum
tank. The maximum distance is 15 feet.
3. Install vacuum pump at same level or lower than vacuum tank
outlet. Do not install pump higher than the vacuum tank outlet.
4. The maximum head pressure on the discharge of the pump must
not exceed 6 feet.
Note: Two-toilet systems require a vacuum pump and vacuum tank for each toilet.
It provides the benet of a totally redundant operating toilet in case of failure in one
toilet. Two pumps greatly reduce hose runs and system complexity.
Installing the pump:
1. Make sure the vacuum pump is properly located before proceeding. Place the vacuum pump on the surface
to be mounted. Position as needed. Using a center punch, mark the four slotted holes in the pump feet.
Remove pump.
2. Using a 3/16-inch drill bit, drill the four mounting holes. Use a #14 wood screw to secure pump.
3. The ow direction is indicated on the pump body.
Stainless steel wall mounting bracket is available as optional accessory – P/N 341505.
Wiring the pump:
Wire the S-series pump as shown in the wiring diagram. Use multistranded copper wire. Proper fuse or circuit
breaker size is extremely important for pump and wire protection (see chart above). Overfusing this pump will
result in warranty invalidation.
Electrical schematic also shows installation of optional “night
switch”.
Dimensional
Specications
Electrical
Specications
S Vacuum Pump with
W Motor
Installation Instructions
IMPORTANT NOTICE
VacuFlush
®
sanitation systems must be installed according to
Dometic’s recommended procedures. Do not attempt installation without rst contacting a SeaLand
Product certied dealer or Dometic Corporation.
ModelVolts (DC)Avg. Amp DrawGPHFuse/BreakerWire SizeWeight
SW1212623010 amps12-14 ga.8 lbs.
SW242432305 amps14-16 ga.8 lbs.
A
B C
Dometic Corporation, Sanitation Division
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611 USA
1-800-321-9886 • Fax: 330-496-3097
www.Dometic.com
Product specificaties
| Merk: | Dometic |
| Categorie: | Toilet |
| Model: | Pump SW12 |
Heb je hulp nodig?
Als je hulp nodig hebt met Dometic Pump SW12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Toilet Dometic
Dometic 310 Handleiding Dometic Dryroll Handleiding Dometic MasterFlush MF 7260 Handleiding Dometic 976 Handleiding Dometic 962 Sanipottie Handleiding Dometic VacuFlush 148 Handleiding Dometic MasterFlush MF 8920 Handleiding Dometic DTM04 Handleiding
Alle Dometic Toilet handleidingen
Populair in Toilet
Handleiding Toilet
Nieuwste handleidingen voor Toilet
Brondell Swash S1000 Handleiding American Standard Colony 250DA004.020 Handleiding American Standard Colony 250BA104.020 Handleiding American Standard H2Option 606CA001.020 Handleiding American Standard Edgemere 608BA001.020 Handleiding TOTO MS854114SG Handleiding American Standard H2Option 606CA002.020 Handleiding American Standard Cadet 609AA001.020 Handleiding American Standard Mainstream 734AA101.020 Handleiding American Standard Cadet 609BA001.020 Handleiding