Doepfer A-170 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Doepfer A-170 (16 pagina's) in de categorie Effect machine. Deze handleiding was nuttig voor 43 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
doepfer System A - 100 Dual Slew Limiter A-170
1
1. Introduction
Module A-170 (Dual Slew Limiter) contains two sepa-
rate slew limiters, also known as portamento control-
lers or integrators.
The upper SL has just one joint control, which sets
both rise and fall times (c. 0 ...10 sec).
The lower SL has separate controls for rise and fall
times, and can therefore be used as a simple AR
envelope generator. Over and above this, you can set
the overall range for these parameters, with a three-
position switch, as on the full ADSRs.
Both slew limiters have two LEDs each, to show the
state of the rising and falling voltages.
In
Control
Time
A-170
DSL
Ï
Out
In
Control Time
Range
Out
Ð
- +
-
+
A-170 Dual Slew Limiter System A - 100 doepfer
2
2. Overview Controls and indicators:
1 Time : rise / fall time control (input 1)
2 6, - LED : negative voltage indicator
2, 6 + LED : positive voltage indicator
3 Ï : rise time control (lower SL)
4 Ð : fall time control (lower SL)
5 Time Range: 3-position switch for overall rise / fall
time range (lower SL)
In / Outputs:
!, § In :Input
", $ Out : Output
A-170
DSL
Out
Control
Ï
Time
In
DUAL SLEW LIMITER
0 10
010
0 10
Control
Out
In
MH L
Time
Range
-
+
-
+
Ð