Dimplex RXPW1 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dimplex RXPW1 (6 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 107 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
Installation and Operating Instructions
TIDN7DP001 Issue 0
RXPW1 - 7 Day Timer/Programmer
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
MODE PROG ENTER
12:13
MAN OFF
M
T
W
T
F
S
S
Fig. 1
General
The RXPW1 can only be used
in the PLX05 electronic range
of heaters.
They offer either individual
programming (each individual
heater has a programming
module) or group programming
from a master heater through
the pilot wire. Group
programming can drive up to
10 slave heaters.
Two heating positions are offered: comfort and off, with
temperatures set using the controls on the heater.
For default Screen see Fig. 1.
Installation
The RXPW1 is rated at 230V.
1. Switch the heater off.
2. Using a narrow bladed screwdriver, carefully release
the cover from the slot on right hand side of the
thermostat on the Panel Heater.
3. Remove the 7-day plug in timer from it’s box and plug
it into the slide in compartment now exposed - see Fig.
2 . Insert the programmer fully so that it clicks into
position. Switch the heater back on at the mains supply.
Individual Programming
Fit one programmer to each EPX heater. (Note: When the
heater is installed, the black pilot wire in the mains supply
cable should be trimmed back in accordance with the
Installation Instructions.
Programming for a Zone
The heater containing the RXPW1 is the Master heater and
connected by the black pilot wire to the Slave heaters. The
Master heater determines the Program and heating levels for
all the heaters (Comfort and Off), but the actual comfort
temperature should still be set on each individual heater (see
EPX Panel Heater instructions). The master heater will switch
between Comfort and Off according to the program.
Electrical Connection Master/Slave Heaters
DO NOT connect the BLACK (PILOT) SIGNAL WIRE to earth.
When the programmer drives other heaters, connect the pilot
wire from the ‘MASTER’ unit to the pilot wire of a ‘SLAVE’
heater and then from one ‘SLAVE’ heater to another (in series)
- see Fig. 3.
LEN
Fig. 2
LEN
MASTER SLAVE SLAVE
PIL OT WIRE
UP TO
10 UN ITS
Fig. 3
Any 240V insulated cable may be used to link pilot wires
around the ring main. The signal current is low. Suitable
connections would be either an additional single core wire
marked or colour coded appropriately or use a 4 core cable
throughout the heater ring.
Operating Instructions
The RXPW1 can be programmed either inserted directly into
the heater or out of the heater. If choosing the latter option,
the cassette must be first left in the heater for 2 days to charge
the battery. Remember that the battery only lasts for 24 hours.
Problem Solving
In the event that no display appears on your 7-day timer do
the following :
1. Press any button to reactivate the display. Failing this -
2. Return to the heater to charge battery (internal battery lasts
for 24 hours when timer is removed from heater). Display will
appear immediately but battery will be fully charged in 2 days.
Mode Selection
There are three different
operating modes. Press MODE
to cycle through these:
MAN OFF - heating is
permanently Off – see Fig. 4.
This is also the default screen.
MAN ON - heating is
permanently On - see Fig. 5.
AUTO - runs the programmed
times - see Fig. 6.
MODE PROG ENTER
12:13
MAN OFF
M
T
W
T
F
S
S
Fig. 4
MODE PROG ENTER
00:00
MAN ON
M
T
W
T
F
S
S
Fig. 5
MODE PROG ENTER
00:00
AUTO ON
M
T
W
T
F
S
S
Fig. 6
Set Time
Press the PROG key once (from default display) to set time.
The appears (see Fig. 7) on
the screen and the hours can be
set using the keys. Press
ENTER when finished setting the
hours.
Set minutes using the keys
and press ENTER.
Then choose the day from Mon
to Sun using the keys and
press ENTER to exit. Time and
Day are now set.
Set Programme
The timer can only be
programmed in 2 blocks i.e.
1st Block - Weekdays: Mon-Fri
Press PROG twice (see Fig. 8).
The Weekday programs are
now ready to be set (starting with
P1 ON P1 ON, where is the first
ON time setting) go to ‘a)’ below:
2nd Block - Weekends: Sat & Sun
Press PROG twice and then
press MODE once (see Fig. 9).
The Weekend programs are
now ready to be set (starting with
P1 ON P1 ON, where is the first
ON time setting), go to ‘a)’ below:
a) set P1 ON time:
Set the hours using and
press ENTER. Then set the
minutes using and press
ENTER.
Note: Time in minutes can only be set in 10 minute blocks.
Then set P1 OFF time:
Set the hours using . and press ENTER
Then set the minutes using and press ENTER. If only
one program is required, press PROG now to return to default
display OR
b) set P2 ON and OFF times: repeat procedure as ‘a)’ above.
c) set P3 ON and OFF times: repeat procedure as ‘a)’.
d) set P4 ON and OFF times: repeat procedure as ‘a)’.
After P4 Weekday OFF time has been set, the
User will be prompted to set P1 ON time for Weekends.
After P4 Weekend OFF time has been set the default Screen
is displayed.
At any time while programming the timer, pressing the PROG
button, this will exit to the default display. Timer must be in
AUTO mode to run Set Programs.
NOTE: To cycle quickly from weekdays to weekends press
the MODE button. There are 4 programs for weekdays and 4
for weekends.
MODE PROG ENTER
00:00
MAN OFF
M
T
W
T
F
S
S
Fig. 7
MODE PROG ENTER
00:00
AUTO OFF
M
T
W
T
F
S
S
ON
P1
MODE PROG ENTER
00:00
AUTO OFF
M
T
W
T
F
S
S
ON
P1
Fig. 8
Fig. 9
Key Lock
To lock the keypad press ENTER
and release, then press MODE
within 1 second. The key symbol
will appear on the screen when
the keypad is locked - see Fig.
10. To unlock the keypad repeat
the action above. If any of the
buttons on the keypad are
pressed when it is locked, the
light will automatically come on.
The Advance Function
When in AUTO mode, if is
pressed for longer than 2
seconds the program will
advance to the next programmed
setting. When the ADVANCE
function is active ADVANCE will
be displayed on the screen - see
Fig. 11.
To cancel ADVANCE press
for
longer than 2 seconds
e.g. If present time is 14:00 and P1 ON is at 17:00 and P1
OFF is 19:00, if is held for 2 seconds then ADVANCE
appears on the screen. The heater comes on and remains on
until 19:00. ADVANCE disappears from the screen at 17:00
as set program is then running.
MODE PROG ENTER
00:00
MAN OFF
M
T
W
T
F
S
S
MODE PROG ENTER
00:00
ON
AUTO
ADVANCE
M
T
W
T
F
S
S
Fig. 10
Fig. 11


Product specificaties

Merk: Dimplex
Categorie: Niet gecategoriseerd
Model: RXPW1

Heb je hulp nodig?

Als je hulp nodig hebt met Dimplex RXPW1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dimplex

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd