Dimplex FX20V Handleiding

Dimplex Heater FX20V

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Dimplex FX20V (3 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 7 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3


Contact Details

Pleasenotethat some contact ofthe details on 
thisPDFdocumentmaynotbe current.

Pleaseuse  the following detailsifyouneedto
contactus:

Telephone:0844 879 3588
Email:customer.services@gdcgroup.co.uk


The widecustomer alsosupportsection websiteofour  features a
rangeof ofinformationwhichmaybe use availabletoyouandis 
24 ahours day.Itincludes:

β€’ Operating   and installation instructions
β€’ Easy       ξ€ƒβ€˜How to use’ guides for storage heaters
β€’ Service  and repairs
β€’ Wheretobuyourproducts
β€’ Literature downloads
β€’ Heating  requirement calculator

 ‐Visit www.dimplex.co.uk/support
A division of GDC Group Ltd
Millbrook House Grange Drive Hedge End Southampton SO30 2DF
www.dimplex.co.uk
Re
g
istered No: 1313016 En
g
land
VAT GB 287 1315 50004
EEE Producer Registration Number –
WEE/GE0057TS
Paper from sustainable sources
Downflow Fan Heater
Model : FX 20V
Installation and Operating Instructions
Dimensions
(millimetres)
Model(s) Specification
FX 20V (High Level) 1/2kw + Adjustable Thermostat (internal by installer)
Fig. 1
(IP22)
IMPORTANT SAFETY ADVICE
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
DO NOT COVER THE APPLIANCE or place material or garments
on it, or obstruct the air circulation around this appliance, for
example with curtains or furniture, as this could cause
overheating and a fire risk.
DO NOT PLACE AEROSOLS OR OTHER CONTAINERS
SUSCEPTIBLE TO HEAT IN THE DIRECT AIRFLOW FROM THE UNIT.
THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A
FIXED SOCKET OUTLET.
WARNING: Do not operate the heater with the top cover removed.
The appliance is not intended for use by children or other persons
without assistance or supervision if their physical, sensory or
mental capabilities prevent them from using it safely. Children
should be supervised to ensure that they do not play with the
appliance.
WARNING – DISCONNECT THE HEATER FROM THE ELECTRICITY
SUPPLY BEFORE UNDERTAKING SERVICE OR REPAIR.
WARNING – If the appliance is fitted in a bathroom, a cable outlet
will be necessary with the supply to the unit controlled by a
double pole switch. The switch if inside the bathroom should be
pull cord operated and if outside should be adjacent to the
entrance door. The appliance must be mounted so that no part of
it can be touched by any person using bath or shower.
THIS HEATER MUST NOT BE OPERATED WITHOUT THE COVER
CORRECTLY IN POSITION.
Warning : In order to avoid a hazard due to inadvertent resetting of
the thermal cutout, this appliance must not be supplied through an
external switching device, such as a timer, or connected to a
circuit that is regularly switched on and off by the utility.
General
The heater has a loading of 2KW. It is designed for permanent wall mounting
and is suitable for operation on A.C. electricity supply having the same
voltage as shown on the rating label.
The heater is fitted with an internally mounted selector switch which on
installation of the heater allows a choice of 1kW or 2kW output to suit the
dimensions of the room to be heated.
In rooms of less than 9 – 11 cubic m. (350 - 400 cubic ft.) 1kW output should
be selected, otherwise nuisance tripping of the thermal overload cut-out
may occur.
NOTE : THE SWITCH HAS BEEN FACTORY SET FOR 1kW OPERATION.
IF ADDITIONAL OUTPUT IS REQUIRED, 2kW CAN BE SELECTED ON
INSTALLATION.
SUPPLY CABLE IS NOT SUPPLIED WITH THIS APPLIANCE AND IT
SHOULD THEREFORE BE INSTALLED BY A COMPETENT ELECTRICIAN
IN ACCORDANCE WITH THE LATEST IEE REGULATIONS.
08/15981/6 Issue 6
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Controls
The cut-out is a safety device which switches off the heater and fan if for
any reason the appliance overheats - see β€˜Safety’.
The thermal fuse link is provided as an added safety feature, and operates
to open circuit if there is abnormal overheating within the appliance. The
operation of these safety devices is described under β€˜Safety’.
The pull cord switch operates the ON/OFF switch. (An indicator light
illuminates to show when the heater is ON and does not illuminate when
the heater is OFF) .
The heater is fitted with an adjustable thermostat, which has three different
settings : 1. - Low, 2. - Medium, 3 - High. This gives you an approximate
room temperature range of 18Β°C - 32Β°C depending on room size. If internal
switch is set to 2kW, the temperature switches to half heat when the room
warms up. Full heat will be switched on automatically when the room
temperature falls. This can be adjusted by installer, by removing top cover.
The thermostat will only function when 2KW is selected. The thermostat
has been factory set on β€˜2’ (Medium).
To adjust the thermostat setting or reset selector switch first remove the top
cover, then adjust thermostat to required setting, or reset selector switch to
1kW or 2kW as required, then refit top cover. Do not operate the unit with
the top cover removed.
Safety
Cut-Out
For your safety, this appliance is fitted with a thermal cut-out. In the event
that the product overheats, the cut-out switches the heater off automatically.
To bring the heater back into operation, remove the cause of overheating,
then turn off the electrical supply to the heater for a few minutes.
When the heater has cooled sufficiently reconnect and switch on the heater.
Fuse Link
A thermal fuse link is provided as an added safety feature. If the fuse link
operates and opens circuit it is the result of abnormal overheating within
the appliance, and servicing of the appliance by a competent service
engineer will be required in order to ensure the future safe operation of the
heater. Dimplex Customer Services should be contacted (see β€œAfter Sales
Service” for details), who will arrange the replacement of any faulty parts
and the fitting of a new fuse link.
Installation
WARNING: Minimum clearences must be adhered to when mounting
the heater.
Before undertaking installation work, ensure the electricity supply is
disconnected from any relevant fixed wiring. Supply cable is not supplied
with this appliance and it should therefore be installed by a competent
electrician in accordance with the latest IEE wiring regulations.
The supply circuit must be adequate for the input of the appliance and
must be protected with a 13A fuse.
A suitable termination to the fixed wiring of the premises must be provided
adjacent to the final position of the appliance through a double pole
switch having a contact separation of at least 3mm in all poles.
250 229
242
109300
MIN
1800
600
MIN
MIN
MIN
floor
ceiling
shelf
Fig. 2
Fig. 4
Installation Procedure
It is essential to observe minimum wall mounting clearances - see Fig. 1.
The appliance should be fitted horizontally, with the cable entry at the top
and grille at the bottom. It must be mounted not less than 1800mm above
the floor with a clearance of at least 600mm to any shelf or projecting
surface below the heater and not less than 300mm below the ceiling or
other projecting surface. It must also be not less than 250mm from an
adjacent projecting surface. For most effective heating performance, the
heater should be mounted at the minimum height : i.e. 1800mm above
the floor.
Care must be taken to ensure that when in use, the air stream is not
obstructed by a high shelf or cabinet.
The appliance is secured to the wall with three screws, two through
keyhole slots and one through a centrally positioned lower hole to hold
the appliance firmly in position (see Fig. 2).
1. Remove the top cover from the appliance by removing the two
screws securing the top cover and hinging it back.
2. Mark the position of the keyhole slots on the wall and drill and plug
for the two suitable screws.
3. Partially insert the two screws, then hang the appliance on these
screws and mark the position of the lower centrally positioned screw.
4. Remove the appliance and drill and plug for the third screw.
5. Remount the appliance on the wall, ensure that it is horizontal and
fix in position by tightening all three screws.
6. Feed the supply cord or wires through the inlet at the top rear of the
appliance leaving sufficient free length to connect to the terminal
block.
7. Make electrical connections to the terminal block ensuring that the
live connection is made to the terminal marked β€˜L’ and the neutral
connection to the terminal marked β€˜N’ (see Fig. 2 exploded view).
8. Operate the selector switch to provide either 1kW or 2kW output.
9. Replace the top cover and screws.
The appliance is now ready for use and the electricity supply can be
reinstated.
FX20V Controls
The heater is fitted with a pull cord
operated ON/OFF switch, a thermostat, a
cut-out, and a thermal fuse link.The
heater has an internal adjustable
thermostat which can be adjusted by
installer (i.e. the top cover has to be
removed), see Fig. 4 for controls details
with cover removed. Temp. range 18Β°C -
32Β°C.
Cleaning and User Maintenance
WARNING: BEFORE UNDERTAKING CLEANING OR MAINTENANCE WORK
ON THE APPLIANCE DISCONNECT THE ELECTRICITY SUPPLY BY
SWITCHING OFF AT THE ADJACENT DOUBLE POLE SWITCH.
The outside can be cleaned by wiping it over with a soft damp cloth and
then dried. Do not use abrasive cleaning powders or furniture polish as this
can damage the surface finish.
Ensure that dust or fluff does not accumulate inside the heater as this could
lead to overheating of the element. Use a vacuum cleaner to remove any
fluff which does accumulate.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should not be
disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for
recycling advice in your country.
After Sales Service
If this product appears damaged when first received or does not
function correctly contact us by e-mail aftersales@dimplex.co.uk or
ring 0844 879 35 88 and we will be able to help. For ROI please phone
018424833.
Do Not Return the product in the first instance as this may delay us
providing you with a satisfactory service.
ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE WARRANTY.
Your product is guaranteed for two years from the date of purchase.
Within this period, we undertake to repair this product free of charge
provided it has been installed and operated in accordance with these
instructions.
Should you require assistance with this product please go to
www.dimplex.co.uk and click on β€œCustomer Support” or e-mail us at
aftersales@dimplex.co.uk
Alternatively ring our contact centre on 0844 879 35 88 (UK only). This is
a Lo-call no. from a BT landline - other providers including mobile
phones may charge you more. For ROI please phone 01 842 4833.
To assist you, we will need the following information: model number and
serial no (these can be found on the product), nature of the fault and date
of purchase. Please retain your receipt as proof of purchase. Your
rights under this guarantee are additional to your statutory rights, which
in turn are not affected by this guarantee.
Spares can be purchased on line, go to www.dimplex.co.uk/outlet_store
M
Fig. 3 - FX20V Wiring Diagram
L
N
selector
switch
internal adjustable
thermostat knob
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014,
EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
Dimplex UK Ltd.
Millbrook House
Grange Drive
Hedge End
Southampton
Hampshire. SO30 2DF
www.dimplex.co.uk
Republic of Ireland Tel. 01 8424833
[c] Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Dimplex UK Limited.


Product specificaties

Merk: Dimplex
Categorie: Heater
Model: FX20V
Kleur van het product: Wit
Warmtebron: Electrisch
Gewicht: 1100 g
Breedte: 229 mm
Diepte: 109 mm
Hoogte: 242 mm
Soort: Radiator/ventilator
Vermogen: 2000 W
Aan/uitschakelaar: Ja
Indicatielampje: Ja
Geschikt voor: Binnen
Instelbare thermostaat: Nee
Ophangsysteem voor aan de muur: Ja
Verwarmingsvermogen: 2000 W
Plaatsingsopties: Muur
Geschikt voor de badkamer: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met Dimplex FX20V stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater Dimplex

Handleiding Heater

Nieuwste handleidingen voor Heater