Digitus DA-90384 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Digitus DA-90384 (5 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/5
A. Operating Control Panel
EN EN
Timer Timer
Memory/Screen lock (unlock) Memory/Screen lock (unlock)
Downward movement Downward movement
Upward movement Upward movement
Memory 1/2/3 Memory 1/2/3
Display Display
Operation Instruction:
1. When the system is powered on, you will hear a beep and the existing desktop
height will be displayed on the controller.
2. Upward movement
Downward movement
Touch the “ ” or “ ” and do not release until the desk reaches the desired height. If
the motor continuously operates for a relatively long period of time, the overheat
protection will activate. The control panel will work normally again after approximately
20 minutes.
3. Memory Mode
To store a certain height in the controller’s memory, first touch “ ”. The letter ” will
be displayed. Now touch ”, “ ”, or within five seconds to store the current height in
memory. The “ ”, “ ”, or “ ” buttons can each store a different height. Once in memory,
you can select any of the 3 height settings found in the controllers memory by
pressing the corresponding button. Touching any buttons (except for ”) will stop the
automatic adjustment.
4. Reset Mode
While the unit is powered on, press the “ ” button until the desk moves into a fully
lowered position, “63.0” or “73.0” is displayed on the controller. Again, press the “
button until “RST” is displayed on the controller. Once the display shows
“62.0” or “72.5”, release the “ button-the desk will move upward for approximately
10mm or 5mm and automatically come to a stop. After finishing the reset, the
controller should display “63.0” or “73.0” which is the current height.
5. Time Reminder
To set the time reminder, press “ ” found on the controller. The display will flash “0.5h”
which means 0.5 hour. Press the “ ” repetitively to increase 0.5 hours at a time. The
maximum timer setting is two hours. The timer is set when the digit stops flashing and
the light in the top right corner of the controller is on. When the timer has reached the
set time, the buzzer beeps, reminding the user to adjust his/her working position.
Once a timer setting has expired, the unit’s timer is cancelled. To de-activate the timer,
press the “ ” five times until the current height is displayed and the light found in the
upper right side of the controller is off.
6. Protective Standby Mode (60 Second)
If you want to prevent accidental operation, long press “ button for 3s to activate
standby mode. The protective standby mode activates when the display shows “---”.
The protective standby mode will also activate when there is no operation over 60s.
To turn off the standby mode, long press the “ ” button for 3s.
7. Power-saving Mode (10 Minutes)
When no actions are made for over 10 minutes, the system will enter power-saving
mode. Touch any button to enter operation mode.
8. Switch measurement between cm and inch
The preset measurement shown on the display is cm. If you would like to change cm
to inch, please restart the system and press the button “ ” for 8 seconds. After the
buzzer beeps twice, the measurement is successfully reset. If you would like to switch
inch back to cm, please restart the system and press the button “ ” for 8 seconds.
After the buzzer beeps once, the system is successfully switched to cm measurement
again.
Trouble Shooting
Below are the possible error codes that may be displayed on the control panel.
Error Code Description
ER1 Overload in downwards direction has occurred and needs to be
restart power.
ER2 Over-heating in the controller has occurred and needs to cool.
ER3 Motor cable connection fault and needs to be reset.
ER4 Both legs have different heights and need to be reset.
ER5 Motor fault
Note:
1. Self-protection function: the unit will enter protective mode if the system operate in
excess of two minutes with “HOT” on the controller display. The system will reset
and return to normal operation after approximately 18 minutes.
2. Overload protection mode: while operating, if the load on the desk is over weight
capacity, the system will enter into an overload protection mode. This will protect
the system from damages caused by exceeding weight. When this happens, the
desk will move downward approximately 30mm and come to a stop with the
current height displayed.
3. Attention: NEVER remove or turn off the power in order to reset the unit when it is
in a protective mode or “HOT” state.
4. Please reset in case two legs are different in height.


Product specificaties

Merk: Digitus
Categorie: Niet gecategoriseerd
Model: DA-90384
Gewicht: 30600 g
Diepte: 700 mm
In hoogte verstelbaar: Ja
Maximale gewichtscapaciteit: 100 kg
Frame kleur: Zwart
Aantal benen/poten: 2 poot/poten
Maximum breedte: 1000 mm
Type hoogteverstelling: Electrisch
Minimale hoogte: 630 mm
Maximale hoogte: 1250 mm
Compatibele breedte bureaublad (max): 2000 mm
Compatibele diepte van bureaublad (min): 700 mm
Compatibele diepte van bureaublad (max): 900 mm

Heb je hulp nodig?

Als je hulp nodig hebt met Digitus DA-90384 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Digitus

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd