Dellโ„ข๎€ƒOptiPlexโ„ข๎€ƒ745๎€ƒSystems๎€ƒUser's๎€ƒGuide
๎€ƒ
๎€ƒ
๎€ƒMini Tower Computer
๎€ƒDesktop Computer
๎€ƒSmall Form Factor Computer
๎€ƒUltra Small Form Factor Computer
Back to Contents Page
๎€ƒ Advanced Features
Dellโ„ข๎€ƒOptiPlexโ„ข๎€ƒ745๎€ƒUser's๎€ƒGuide
๎€ƒLegacySelect Technology Control
LegacySelect technology control offers legacy-full, legacy-reduced, or legacy-free solutions based on common platforms, hard-drive images, and help desk
procedures.๎€ƒControl๎€ƒis๎€ƒprovided๎€ƒto๎€ƒthe๎€ƒadministrator๎€ƒthrough๎€ƒsystem๎€ƒsetup,๎€ƒDell๎€ƒOpenManageโ„ข๎€ƒIT๎€ƒAssistant,๎€ƒor๎€ƒDell๎€ƒcustom-factory integration.
LegacySelect allows administrators to electronically activate or deactivate connectors and media devices that include serial and USB connectors, a parallel
connector, a floppy drive, PCI slots, and a PS/2 mouse. Connectors and media devices that are deactivated make resources available. You must restart the
computer to effect the changes.
๎€ƒManageability
๎€ƒ
Alert Standard Format
ASF is a DMTF management standard that specifies "pre-operating system" or "operating system-absent" alerting techniques. The standard is designed to
generate an alert on potential security and fault conditions when the operating system is in a sleep mode or the system is turned off. ASF is designed to
supersede previous operating-system-absent alerting technologies.
Your computer supports the following ASF version 1.03 and 2.0 alerts and remote capabilities:
ASF allows Remote Management and Control Protocol (RMCP) messages to be exchanged between a remote management console and a client computer that
is in a "pre-operating system" or "operating system-absent" state. RMCP messages can be sent to instruct a client computer to start up, shut down, or
restart.
For more information about Dell's ASF implementation, see the ASF User's Guide and the ASF Administrator's Guide, which are available on the Dell Support
website at support.dell.com.
๎€ƒ
Dell๎€ƒOpenManageโ„ข๎€ƒApplications
You can manage your system via IT Assistant, Dell Client Connector Utility (DCCU), and Dell OpenManage Client Instrumentation (OMCI).
IT Assistant configures, manages, and monitors computers and other devices on a corporate network. IT Assistant manages assets, configurations, events
(alerts), and security for computers equipped with industry-standard management software. It supports instrumentation that conforms to SNMP and CIM
industry standards.
For information on IT Assistant, see the Dell OpenManage IT Assistant User's Guide available on the Dell Support website at support.dell.com.
Dell OpenManage Client Instrumentation is software that enables remote management programs such as IT Assistant to do the following:
๎€ƒ๎€ƒLegacySelect Technology Control
๎€ƒ๎€ƒManageability
๎€ƒ๎€ƒPhysical Security
๎€ƒ๎€ƒTrusted Platform Module (TPM)
๎€ƒ๎€ƒSecurity Management Software
๎€ƒ๎€ƒComputer Tracking Software
๎€ƒ๎€ƒAbout Smart Cards and Fingerprint Readers
๎€ƒ๎€ƒPassword Protection
๎€ƒ๎€ƒSystem Setup
๎€ƒ๎€ƒBooting to a USB Device
๎€ƒ๎€ƒJumper Settings
๎€ƒ๎€ƒClearing Forgotten Passwords
๎€ƒ๎€ƒClearing CMOS Settings
๎€ƒ๎€ƒHyper-Threading and Dual-Core Technology
๎€ƒ๎€ƒPower Management
๎€ƒ
Alert
๎€ƒ
Description
Chassis: Chassis Intrusion โ€“ Physical Security
Violation/Chassis Intrusion Physical Security Violation โ€“
Event Cleared
The computer chassis with the chassis intrusion feature (optional on some
computers) installed and enabled has been opened or the chassis intrusion alert has
been cleared.
CPU: Emergency Shutdown Event
The processor temperature is too hot and the power supply has shut down.
Cooling Device: Generic Critical Fan Failure/Generic Critical
Fan Failure Cleared
The fan speed (rpm) is out of limits or the fan speed (rpm) problem has been
resolved.
Temperature: Generic Critical Temperature Problem/Generic
Critical Temperature Problem Cleared
The computer temperature is out of limits or the computer temperature problem has
been resolved.
Battery Low
The system battery has reached a voltage of 2.2 V or lower.
l ๎€ƒAccess information about your computer, such as how many processors it has and what operating system it is running.
l ๎€ƒMonitor the status of your computer, such as listening for thermal alerts from temperature probes or hard-drive failure alerts from storage devices.
A system that has Dell OpenManage Client Instrumentation set up on a network that uses IT Assistant is a managed system. For information about Dell
OpenManage Client Instrumentation, see the Dell OpenManage Client Instrumentation User's Guide available on the Dell Support website at support.dell.com.
With Dell Client Connector Utility (DCCU) you can change the state of your computer by, for example, updating or configuring its BIOS or shutting it down
remotely. For more information about DCCU, see the Dell Support website at support.dell.com.
๎€ƒ
Dell Client Manager (DCM)
๎€ƒ
Dell Client Manager (DCM) Console
The Dell Client Manager (DCM) console allows you to configure, manage, and monitor Dell computers on a corporate network via a simple GUI interface.
Through the DCM console you can manage assets, configurations, events (alerts), status, and security for computers equipped with industry-standard
management software. For information about standards supported by DCM, see www.altiris.com.
For information about the DCM console, see www.altiris.com or the Dell Support website at support.dell.com.
The DCM console also allows you to:
l ๎€ƒAccess information about your computer, such as how many processors it has and what operating system it is running.
l ๎€ƒMonitor the status of your computer, such as listening for thermal alerts from temperature probes or hard-drive failure alerts from storage devices.
l ๎€ƒChange the state of your computer by updating its BIOS, configuring BIOS settings, or shutting it down remotely.
With Dell Client Manager installed on a console and its client software installed on client computers, you have a managed system. For information about DCM,
see the Dell Support website at support.dell.com.
๎€ƒPhysical Security
๎€ƒ
Chassis Intrusion Detection
This (optional on some computers) feature, if installed and enabled, detects that the chassis was opened and alerts the user. To change the Chassis
Intrusion setting:
๎€ƒ
1. Enter system setup (see Entering System Setup).
๎€ƒ
2. -Press the down arrow keys to move to the System Security option.
๎€ƒ
3. -Press <Enter> to access the System Security option's pop up menu.
๎€ƒ
4. -Press the down arrow key to move to the Chassis Intrusion setting.
๎€ƒ
5. Press <Enter> to select an option setting.
๎€ƒ
6. Press <Enter> again after you update the option setting.
๎€ƒ
7. Exit and save system setup.
๎€ƒ
Option Settings
l ๎€ƒ โ€”On If the computer cover is opened, the setting changes to Detected, and the following alert message displays during the boot routine at the next
computer start-up:
Alert! Cover was previously removed.
To reset the Detected setting, enter system setup (see Entering System Setup). In the Chassis Intrusion option, press the left- or right-arrow key to
select Reset, and then choose On, . On-Silent, or Off
l ๎€ƒ โ€”On-Silent (default setting) If the computer cover is opened, the setting changes to Detected. No alert message appears during the boot sequence
at the next computer start-up.
NOTE: When the administrator password is enabled, you must know the administrator password before you can reset the Chassis Intrusion setting.