Bekijk gratis de handleiding van Daytronic 10A31-4 (8 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 20 mensen en kreeg gemiddeld 4.9 sterren uit 4 reviews. Heb je een vraag over Daytronic 10A31-4 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/8

1GENERALDESCRIPTIONANDSPECIFICATIONS
The Model 10A31-4 is for measurement of displacement, force, pressure, and other
parameters obtained with a
variable reluctance transduceror linearvariable dif-
ferential transformer (LVDT)
. Based on the synchronous carrier-demodulatorprin-
ciple, it supplies regulated, remotely sensed AC excitation for four independent
transducer channels. It then demodulates, filters, and amplifies the resulting signals to
produce system outputs precisely proportional to LVDT core displacement. The
10A31-4 automatically adjusts to the signal phase shift of the transducer in use, there-
by insuring optimum sensitivity and linearity. Special input provisions exist for “long-
stroke” LVDT's (full-scale range of ±1 inch or greater).
For each of its four analog inputs, the 10A31-4 produces two displayable outputs: one
with “normal” analog filtering and one with
high bandwidth characteristics (see Speci-
fications and Table 1, below). All four channels share a common sensed excitation of
100 mA (rms), maximum. As explained in Section 2, for cables over 25 feet in length,
this limits the distance from the sense point to the transducer to about 20 feet of 18-
gage wire.
The 10A31-4's eight SUBCHANNELS are assigned as follows:
Table 1 Model 10A31-4 Subchannels
Subchannel No.Function
1Input No. 1, low-bandwidth filter
2Input No. 2, low-bandwidth filter
3Input No. 3, low-bandwidth filter
4Input No. 4, low-bandwidth filter
5Input No. 1, high-bandwidth filter
6Input No. 2, high-bandwidth filter
7Input No. 3, high-bandwidth filter
8Input No. 4, high-bandwidth filter
ADDITIONAL10A31-4 SPECIFICATIONS
Transducer Types
: 5- or 7-wire LVDT's capable of 3280-Hz operation and having pri-
mary impedance of 80 ohms or greater (all Daytronic LVDT transducers are suit-
able); 3- or 5-wire variable reluctance transducers
Sensitivity Range: Accommodates full-scale ranges from ±0.010 in. (±0.25 mm) to
±6.0 in. (±15.24 cm), when used with Daytronic or equivalent transducers; for System
10 channel “type” codes assigned to 10A31-4 data channels, see Table 2, below
Standard Input (rms, full-scale): 78, 156, or 312 mV/V
Long-Stroke Input (rms, full-scale): 525 mV/V, 1.05 V/V, or 2.10 V/V
(cont’d)
MODEL10A31-4
QUADLVDT
C
ONDITIONERCARD
GENERALDESCRIPTIONANDSPECIFICATIONS10A31-4.1
SYSTEM10
ANALOGINPUTCARDS
1.E.2.10A31-4
Product specificaties
| Merk: | Daytronic |
| Categorie: | Niet gecategoriseerd |
| Model: | 10A31-4 |
Heb je hulp nodig?
Als je hulp nodig hebt met Daytronic 10A31-4 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Daytronic
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
26 Augustus 2026
26 Augustus 2026
26 Augustus 2026
26 Augustus 2026
26 Augustus 2026
26 Augustus 2026
26 Augustus 2026
26 Augustus 2026
26 Augustus 2026
26 Augustus 2026