Daikin FTXS42G Handleiding

Daikin Airco FTXS42G

Lees hieronder de 📖 handleiding in het Nederlandse voor Daikin FTXS42G (14 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 74 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/14
R410A Split Series
INSTALLATION MANUAL
DAIKIN ROOM AIR CONDITIONER
EnglishDeutschFrançaisNederlandsEspañolItaliano
ΕλληνικÜ
Portugues
Рóссêий
Türkçe
Installation manual
Installationsanleitung
Manuel d’installation
Montagehandleiding
Manual de instalación
Manuale d’installazione
Manual de Instalação
MODELS
FTXS60GV1B
FTXS71GV1B
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
DAIKIN INDUSTRIES, LTD.
Low Voltage 2006/95/EC
Electromagnetic Compatibility 2004/108/EC
*
3SB64526-10B
Shinri Sada
Manager Quality Control Department
1st. of Sep. 2009
DAIKIN.TCF.015 M11/08-2009
FTXS60GV1B, FTXS71GV1B
KEMA Quality B.V.
74736-KRQ/EMC97-4957
1English
Safety Precautions
The precautions described herein are classified as WARNING and CAUTION. They both contain important
information regarding safety. Be sure to observe all precautions without fail.
Meaning of WARNING and CAUTION notices
WARNING ....Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION ..... Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
The safety marks shown in this manual have the following meanings:
After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
WARNING
Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal
connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.
When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and
use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury.
During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in
the refrigeration cycle, which may result in equipment damage and even injury.
During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
CAUTION
Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
While following the instructions in this installation manual, install drain piping to ensure proper drainage and
insulate piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.


Product specificaties

Merk: Daikin
Categorie: Airco
Model: FTXS42G
Kleur van het product: Wit
Timer: Ja
Soort: Splitssysteem
Koelend medium: R410A
Air conditioner functies: Cooling,Fan,Heating
Energie-efficiëntieklasse (verwarming) (gemiddelde stookseizoen): A
Jaarlijks energieverbruik (koelen): - kWu
Jaarlijks energieverbruik (verwarming) (warmer stookseizoen): - kWu
Jaarlijks energieverbruik (verwarming) (gemiddelde stookseizoen): - kWu
Energie-efficiëntieklasse (koeling): A
Extern geluidsniveau: - dB
Intern geluidsniveau (hoge snelheid): 42 dB
Luchtfilter: Ja
Koelcapaciteit in watt (opgegeven): 4200 W
Verwarmingscapaciteit in watt (opgegeven) (warmer stookseizoen): 5400 W
Verwarmingscapaciteit in watt (opgegeven) (gemiddelde stookseizoen): - W
Verwarmingscapaciteit in watt (opgegeven) (kouder stookseizoen): - W
Energieverbruik per uur (koeling): - kWu
Energieverbruik per uur (verwarming): - kWu
Breedte binnenunit: 800 mm
Diepte binnenunit: 215 mm
Hoogte binnenunit: 295 mm
Koelcapaciteit (max): 17100 BTU/h
Koel capaciteit in watt (max): 5000 W
Verwarmingscapaciteit in watt (max): 6000 W
Koeling energie efficientie: 3.47
Verwarming energie efficientie: 3.72
Indoor unit type: Muur-montage
Indoor eenheid gewicht: 10000 g
Jaarlijks energieverbruik (verwarming) (kouder stookseizoen): - kWu
Ontwerpbelasting (koeling): - kW
Ontwerpbelasting (verwarming) (warmer stookseizoen): - kW
Ontwerpbelasting (verwarming) (gemiddelde stookseizoen): - kW
Ontwerpbelasting (verwarming) (kouder verwarmingsseizoen): - kW
Outdoor eenheid gewicht: 39000 g
Breedte buitenunit: 765 mm
Diepte buitenunit: 285 mm
Hoogte buiteneenheid: 550 mm
Indoor units hoeveelheid: 1
Outdoor units hoeveelheid: 1
AC-ingangsspanning: 220 - 240 V
AC-ingangsfrequentie: 50 Hz
Verwarmingscapaciteit (max): 18400 BTU/h
Energieverbruik (koelen) (max): 2330 W
Energieverbruik (verwarmen) (max): 1980 W
Koelcapaciteit in watt (min): 1700 W
Verwarmingscapaciteit in watt (min): 1700 W
Koelcapaciteit (min): 5800 BTU/h
Verwarmingscapaciteit (min): 5800 BTU/h
Verkoelende luchtstroom (indoor eenheid): 546 m³/uur
Opwarmende luchtstroom (indoor eenheid): 672 m³/uur
Energieverbuik (koelen) (min): 440 W
Energieverbruik (verwarmen) (min): 400 W
Comfort-slaapstand: Ja
Binnenunit geluidsniveau (lage snelheid): 30 dB
Binnenunit geluidsvermogensniveau: 58 dB
Gasslang diameter: 9.52 mm
Afvoerslang diameter: 18 mm
Vloeistofslang diameter: 6.35 mm
Buitenunit pakketgewicht: 45000 g
Buitenunit pakketbreedte: 906 mm
Buitenunit pakkethoogte: 612 mm
Buitenunit pakketdiepte: 364 mm
Binnenunit pakketbreedte: 870 mm
Binnenunit pakkethoogte: 366 mm
Binnenunit pakketdiepte: 274 mm
Binnenunit pakketgewicht: 13000 g
Stroomsterkte (koeling): 7.2 A
Stroomsterkte (verwarming): 7.2 A
Ventilatorsnelheid binnenunit (koeling, lage snelheid): 1020 RPM
Ventilatorsnelheid binnenunit (koeling, gemiddelde snelheid): 1170 RPM
Ventilatorsnelheid binnenunit (koeling, hoge snelheid): 1310 RPM
Ventilatorsnelheid binnenunit (verwarming, lage snelheid): 1050 RPM
Ventilatorsnelheid binnenunit (verwarming, gemiddelde snelheid): 1230 RPM
Ventilatorsnelheid binnenunit (verwarming, hoge snelheid): 1410 RPM
Ventilatormotortype (binnenunit): DC

Heb je hulp nodig?

Als je hulp nodig hebt met Daikin FTXS42G stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Daikin

Handleiding Airco

Nieuwste handleidingen voor Airco