Daikin EKWUFHTA1V3 Handleiding


Bekijk gratis de handleiding van Daikin EKWUFHTA1V3 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 5.0 sterren uit 1.5 reviews. Heb je een vraag over Daikin EKWUFHTA1V3 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
1
EKWUFHTA1V3
These instructions must be read completely and thoroughly before commencing
any work with the base. These instructions must be kept and are to be handed
over to future users.
The following symbols show
The base serves
the arrangement of a room-by-room temperature control system with a
the connection of a maximum of 18 actuators and 10 room control units,
the connection of actuators with the direction of control action NC (normally
closed) or NO (normally open), depending on the thermostat used,
the connection of an external timer,
depending on the type used, the connection of a pump or a boiler, a CO
signal generator, a temperature limiter or dew point sensor,
a xed installation.
Every other use, modication and conversion is expressly forbidden and leads to
dangers the manufacturer cannot be held liable for.
The electrical installation must be performed according to the current national
regulations as well as according to the regulations of your local electric power
utility company. These instructions presume specialist knowledge corresponding
to an o󰀩cially recognised degree in one of the following professions:
Systems Mechanic for sanitary, heating and air condition technology
Electrical Equipment Installer or
Electronics Engineer
according to the profession designations o󰀩cially announced in the Federal Re-
public of Germany, and to comparable professions within the European Com-
munity Law.
All safety notes in these instructions must be observed in order to avoid acci-
dents involving personal harm and/or property damage.
WARNING
Danger to life due to the electrical voltage at the base station!
Always disconnect from the mains network and secure against unintended
activation before opening.
Only an authorised electrician may open the device.
Disconnect external voltages and secure against activation.
Only use the product if it is in perfect state.
Do not operate the device without the device cover.
This unit is not intended to be used by persons (including children) with restrict-
ed physical, sensory or mental skills or those who lack experience or knowl-
edge. If necessary, these persons must be supervised by a person responsible
for their safety or receive instructions from this person on how to use this unit.
-Ensure that children do not play with this device. Children must be super
vised if necessary.
In case of emergency, disconnect the complete room-by-room temperature
control system.
The following instructions show the full equipment. Individual positions may be
omitted depending on the present base.
This product is labelled with the CE Marking and thus is in compliance with
following regulations:
2014/30/EU with amendments Council Directive on the approximation of the
laws of the Member States relating to Electromagnetic Compatibility
2014/35/EU with amendments “Council for Coordination of the Regulations
of EU Member Countries regarding the electrical equipment for use within
certain voltage limits
2011/65/EU “Restriction of the Use of Certain Hazardous Substances in
Electrical and Electronic Equipment
Increased protection requirements may exist for the overall installation, the com-
pliance of which is the responsibility of the installer.
1 Boiler connection
2 Pump connection
3 Protective conductor connection
(only for 230 V)
4 Voltage supply
5 Fuse
6 Temperature limiter or dew point
sensor
7 Reduction channel, external timer
8 Heating/cooling change-over
9 Thermostat connection
10 LEDs
11 Strain relief
12 Connection of actuators
13 DIP switch
14 Contacts for casing cover with
integrated system clock
1 Scope of supply
2 About these instructions
3 Safety
3.1 Intended use
3.2 Safety notes
3.3 Personnel-related preconditions
4 Device overview
4.1 Connections and indications
4.2 Technical data
4.3 Conformity
important information.
a warning with respect to electrical voltage
1x 2x
T4AH
Operating voltage: 230 V ±10 %, 50 Hz
Power input 230 V: max. 50 VA
Fuse 230 V: T4AH
Number of heating zones: 10
Connectable actuators Type EKWCVATR1V3
10 heating zones: max. 18
The following applies to other actuators than those mentioned above
Inrush current per actuator: max. 500 mA (for 230 V)
Pump/boiler control
Switching power: 2 A, 200 VA inductive
Turn-on delay: 2 min
Follow-up time fixed/adjustable:
2 min / 5 - 15 min
Pump protection function: 14 days for 1 minute
Control direction: NC or NO
Ambient temperature: 0 to +50 °C
Storage temperature: -20 to +70 °C
Ambient humidity: 80%, not condensing
Temperature for ball pressure test:
Terminals: 100 °C
Plastic enclosures: 75 °C
Pollution degree: 2
Rated impulse voltage: 1500 V
ERP class acc. to EU 811/2013: 1=1 %
Protection class 230 V: II
Protection type: IP 20
Type action: Type 1 / Type 1.C
Dimensions (H x L x D): 90 x 326.5 x 50 mm
6 7 8 9 102 3 4 5
11121314
1
INSTALLATION MANUAL
Multi-zoning base unit 230 V
https://qr.daikin.eu?N=EKWUFHTA1V3
2
1. Take o󰀨 the cover.
2. Install the base. In case of wall mounting, x the base to the wall with 2
Ø 4 mm screws and corresponding dowels based on the quality of the wall.
In case of installation on a mounting bracket, use a TS 35/7.5 bracket.
3. Make the electric connection.
4. Install the cover.
The control direction is set with jumper 1:
NO operation: Jumper 1 = ON
NC operation: Jumper 1 = OFF
The xed follow-up time of 2 minutes of the pump or
the boiler can be increased by an additional 5, 10 or
15 minutes using jumper 2 and 3:
Only use a dry and solvent-free, soft cloth for cleaning.
De-energise the complete installation.
Remove the wiring to all externally connected components.
Remove the base and dispose of it properly, if necessary.
WARNING! Electrical voltage! Danger to life!
Always disconnect the base from the mains network and secure
against unintended activation before opening.
Disconnect external voltages and secure against unintended activation.
WARNING! Electrical voltage! Danger to life!
Always disconnect the base from the mains network and secure
against unintended activation before opening.
Disconnect external voltages and secure against unintended activation.
These instructions are protected by copyright. All rights reserved. They may not be copied, reproduced, abbreviated or transmitted,
neither in whole nor in parts, in any form, neither mechanically nor electronically, without the previous consent of the manufacturer.
1 32
21
230 V
T4AH
230 V
T4AH
NC
NO
0min 5min
10min 15min
2 32 3
2 32 3
Time Jumper 2 Jumper 3
0 min OFF OFF
5 min ONOFF
10 minutes ON OFF
15 minutes ON ON
Function Colour Explanation
Pump/boiler Green On: Pump/boiler active
O󰀨: Pump/boiler inactive
Flashing: Temperature limiter/dew point sensor active
Mains voltage Green On: Device in operation
O󰀨: Device not in operation
Flashing: Valve protection function active (Option)
Fuse Red On: Fuse defective
Change over Blue On: Cooling mode active
O󰀨: Heating mode active
Heating zones
1 to 10
Green On: Heating zone active
O󰀨: Heating zone o󰀨
For the connection of the voltage supply, the cable sections must be 1.5 mm² for 230 V. Depending on the voltage version of the base, it is possible to take L1 or
L and L2 or N, as well as the protective conductor, from the base. A temperature limiter/dew point sensor can be connected to the contact TB/%H in NC operation;
this contact cannot be used in NO operation. If no temperature limiter is connected, the connection TB/%H must be bridged (provided for at the factory). The bridge
must be removed as soon as a temperature limiter is connected. The temperature limiter must be a normally closed contact.
Heating/cooling change-over
Cooling
Heating
System clock
Voltage source
Temperature limiter
Pump
Boiler
Actuator
Analogue thermostat
Digital controller
~
CO
5 Installation
5.1 Select and insert the fuse
5.2 Parametrization
6 Electric connection
7 LED signalling
8 Maintenance
8.1 Fuse change
8.2 Cleaning
9 Dismantling
The wiring of the thermostats
depends on the present ba-
sis. For wiring purposes,
please observe the instruc-
tions of the thermostat or of
the respective component.
The voltage used must
be marked on the
identication plate.
2a
1
Cable bridge in the
parametrization
NO operation
for all unused
thermostat
connections.
2b 2b
3
N/L2
CO
A
L/L1
N/L2
CO
A
L/L1
%H
N/L2
L/L1
CO
N
L
~
PE
N
L
PE
This symbol means that electrical and electronic products may NOT be mixed with unsorted household
waste. Units must be treated at a specialized treatment facility for reuse, recycling and recovery.
4P560992-1 2019.01 Copyright 2019 Daikin