Bekijk gratis de handleiding van Daikin EHVH08S18CB3VF (8 pagina’s), behorend tot de categorie Ketel & boiler. Deze gids werd als nuttig beoordeeld door 14 mensen en kreeg gemiddeld 4.9 sterren uit 7.5 reviews. Heb je een vraag over Daikin EHVH08S18CB3VF of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/8
Installationandoperationmanual
DaikinAlthermasimplifieduserinterface English
Installationandoperation
manual
DaikinAlthermasimplifieduserinterface
EKRUCBS
TableofContents
Installationandoperationmanual
2
EKRUCBS
DaikinAlthermasimplifieduserinterface
4P3822511–2014.06
TableofContents
Fortheuser 2
1 Buttons 2
2 Statusicons 2
Fortheinstaller 3
3 Overview:Installationandconfiguration 3
4 Toconnectthesimplifieduserinterface 3
5 ToupdatethesoftwarewithUpdater 3
6 Toupdatethesoftwaremanually 4
Fortheuser
1 Buttons
b
e
c
a
d
aSPACEHEATING/COOLINGCONTROL
Gototheroomtemperaturehomepage,whereyoucan:
▪ Readouttheactualroomtemperature.
▪ Press or toadjustthedesiredroomtemperature.
▪ Press toturnONorOFFtheroomtemperaturecontrol.
bDOMESTICHOTWATERCONTROL
Gotothedomestichotwaterhomepage,whereyoucan:
Read out the actual domestic hot water tank temperature
(onlyifthesystemcontainsadomestichotwatertank).
▪ Read out the desired instant domestic hot water
temperature (only in case of instant domestic hot water
productionbyaboiler).
Press  to turn ON or OFF the domestic hot water
control.
cDHWTANKBOOSTERMODE
Activate the DHW tank booster mode (only if the system
contains a domestic hot water tank, and provided that the
domestichotwatercontrolisturnedON).
dON/OFF
Turn ONorOFF thespace heating/coolingor domestichot
watercontrol(ontherespectivehomepages).
e NAVIGATIONBUTTONS
Adjust the desired room temperature (on the room
temperaturehomepage).
2 Statusicons
Icon Description
Spaceoperationmode=Heating.
Spaceoperationmode=Cooling.
Domestichotwateroperation.
TheDHWtankboostermodeisactive.
Unitisoperating.
Actualtemperature.
Desiredtemperature.
Amalfunctionoccurred.
Emergencyoperationisactive.
If  or  is displayed, check the main user interface for more
informationor,ifnecessary,contactyourinstaller.
3Fortheinstaller
Installationandoperationmanual
3
EKRUCBS
DaikinAlthermasimplifieduserinterface
4P3822511–2014.06
Fortheinstaller
3 Overview:Installationand
configuration
Installation
▪ Thesimplifieduserinterfacecanonlybeusedincombinationwith
themainuserinterface.
The main user interface acts as control centre and needs to be
installedneartheunit.
▪ The simplifieduser interfaceacts as roomthermostatandneeds
tobeinstalledintheroomthatyouwantittocontrol.
Configuration
Itisrequiredthatthesimplifieduserinterfacehasthesamesoftware
versionasthemainuserinterface.Ifnecessary,updatetheleastup
todate interface. You can find the software version on the box of
eachinterface.
Therearetwowaystoupdatethesoftware:
▪ ByusingtheUpdatersoftware.
▪ Bymanuallyupdatingthesoftware.
INFORMATION
Toupdatethesoftware,itisrecommendedtouseUpdater.
Updatingthesoftwaremanuallycantakeupto2.5hours.
4 Toconnectthesimplified
userinterface
1Connect thecableofthe simplifieduserinterface totheindoor
unit.
X2M
X5M
A2P A2P
21
a b
aMainuserinterface
bSimplifieduserinterface
2Fixthecablewithcabletiestothecabletiemountings.
5 Toupdatethesoftwarewith
Updater
Prerequisite: PC with Updater (contact your dealer for the correct
versionofthesoftware)
Prerequisite:PCUSBcableEKPCCAB3orhigher(includesaUSB
cableandadditionalconnectioncables)
1MakesurethattheindoorunitispoweredOFF.
2ConnecttheuserinterfacetothePC.
X1A
X1A
ab c
d
aPCwithUpdater
bUSBcable
cUserinterfacePCB
dToindoorunit
3PowerONtheindoorunit.
4OpenUpdater.
5InUpdater,goto"Updateprocedure".
6Type in the name of the interface (EKRUCBL* or EKRUCBS,
dependingonwhichyouareupdating).
7Selectthedesiredlanguagepack(onlyforEKRUCBL*).
8Followtheonscreeninstructions.