1
Read Before Operation
Contents
îš„Read Before Operation
Safety Precautions ....................................... 1
Names of Parts ............................................ 3
îš„Multi Connection
Note for Multi System .................................. 5
îš„Care
Care and Cleaning ....................................... 7
îš„When the Need Arises
Troubleshooting ........................................... 9
Safety Precautions
Read the precautions in this manual carefully
before operating the unit. This appliance is îž‚lled with R32.
•Keepthismanualwheretheusercaneasilyndit.
•TheprecautionsdescribedhereinareclassiedasWARNINGandCAUTION.Theybothcontainimportantinformationregarding
safety. Be sure to observe all precautions without fail.
WARNING CAUTION
Failure to follow these instructions properly may result in
personal injury or loss of life.
Failure to follow these instructions properly may result in
property damage or personal injury, which may be serious
depending on the circumstances.
Never attempt. Be sure to follow the
instructions.
Be sure to establish an earth
connection.
•Afterreading,keepthismanualinaconvenientplacesothatyoucanrefertoitwhenevernecessary.Iftheequipmentis
transferred to a new user, be sure also to hand over the manual.
WARNING
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer.
• Theappliancemustbestoredinaroomwithoutcontinuouslyoperatingignitionsources(forexample:openames,an
operating gas appliance or an operating electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.
• Theappliancemustbeinstalled,operatedandstoredinaroomwithaoorarealargerthan12.4m
2. Maintain an
installationheightof2.5mormorefromtheoorsurfacetothebottomoftheappliance.Ifthesizeoftheroomwhere
theapplianceistobeinstalledhaslessthantheindicatedminimumoorarea,installitinawellventilatedroom.
• Toavoidre,explosionorinjury,donotoperatetheunitwhenharmfulgases(e.g.ammableorcorrosive)are
detected near the unit.
• Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too
warm, can be harmful to your physical condition and health.
• Donotplaceobjects,includingrods,yourngers,etc.,intheairinletoroutlet.Productdamageorpersonalinjurymay
result due to contact with the air conditioner’s high-speed fan blades.
• Donotattempttorepair,dismantle,reinstallormodifytheairconditioneryourselfasthismayresultinwaterleakage,
electricshockorrehazards.
• Donotuseammablesprayneartheairconditioner,orotherwiseremayresult.
• Donotusearefrigerantotherthantheoneindicatedontheoutdoorunit(R32)wheninstalling,movingorrepairing.
Usingotherrefrigerantsmaycausetroubleordamagetotheunit,andpersonalinjury.
• Toavoidelectricshock,donotoperatewithwethands.
2
WARNING
• Bewareofreincaseofrefrigerantleakage.Iftheairconditionerisnotoperatingcorrectly,i.e.notgeneratingcoolor
warmair,refrigerantleakagecouldbethecause.Consultyourdealerforassistance.Therefrigerantwithintheair
conditionerissafeandnormallydoesnotleak.
However,intheeventofaleakage,contactwithanakedburner,heaterorcookermayresultingenerationofnoxious
gas.Donotusetheairconditioneruntilaqualiedservicepersonconrmsthattheleakagehasbeenrepaired.
•
Donotattempttoinstallorrepairtheairconditioneryourself.Improperworkmanshipmayresultinwaterleakage,electric
shockorrehazards.Pleasecontactyourlocaldealerorqualiedpersonnelforinstallationandmaintenancework.
• Iftheairconditionerismalfunctioning(givingoffaburningodour,etc.),turnoffpowertotheunitandcontactyour
localdealer.Continuedoperationundersuchcircumstancesmayresultinafailure,electricshockorrehazards.
• Besuretoinstallanearthleakagecircuitbreaker.Failuretoinstallanearthleakagecircuitbreakermayresultin
electricshockorre.
• Besuretoearththeunit.Donotearththeunittoautilitypipe,lightningconductorortelephoneearthlead.Imperfect
earthingmayresultinelectricshock.
CAUTION
•
Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air conditioner for cooling precision
instruments,food,plants,animalsorworksofartasthismayadverselyaffecttheperformance,qualityand/orlongevityoftheobjectconcerned.
• Donotexposeplantsoranimalsdirectlytotheairowfromtheunitasthismaycauseadverseeffects.
•
Donotplaceappliancesthatproducenakedamesinplacesexposedtotheairowfromtheunitasthismayimpaircombustionoftheburner.
• Donotblocktheairinletsnoroutlets.Impairedairowmayresultininsufcientperformanceortrouble.
• Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or
toppling down, thus resulting in injury, product malfunctioning, or product damage.
•
Donotplaceobjectsthataresusceptibletomoisturedirectlybeneaththeindoororoutdoorunits.Undercertainconditions,condensationon
themainunitorrefrigerantpipes,airlterdirtordrainblockagemaycausedripping,resultinginfoulingorfailureoftheobjectconcerned.
•
Afterprolongeduse,checktheunitstandanditsmountsfordamage.Iftheyareleftinadamagedcondition,theunitmayfallandcauseinjury.
• Toavoidinjury,donottouchtheairinletoraluminiumnsoftheindoororoutdoorunits.
• Theapplianceisnotintendedforusebyunattendedyoungchildrenorinrmpersons.Impairmentofbodilyfunctions
and harm to health may result.
• Childrenshouldbesupervisedtoensurethattheydonotplaywiththeunitoritsremotecontroller.Accidental
operation by a child may result in impairment of bodily functions and harm health.
• Avoidimpactstotheindoorandoutdoorunits,orotherwiseproductdamagemayresult.
• Donotplaceammableitems,suchasspraycans,within1moftheairoutlet.
The spray cans may explode as a result of hot air from the indoor or outdoor units.
•
Becarefulnottoletpetsurinateontheairconditioner.Urinationontheairconditionermayresultinelectricshockorre.
•
Donotwashtheairconditionerwithwater,asthismayresultinelectricshockorre.
•
Donotplacewatercontainers(vases,etc.)abovetheunit,asthismayresultinelectricshockorrehazardsiftheyshouldtoppleover.
•
Donotinsertthebatteriesinthewrongpolarity(+/-)orientationasthismayresultinshortcircuiting,re,orbatteryleakage.
• Toavoidoxygendepletion,ensurethattheroomisadequatelyventilatedifequipmentsuchasaburnerisused
together with the air conditioner.
•
Beforecleaning,besuretostopunitoperationandturnoffthecircuitbreaker.Otherwise,anelectricshockandinjurymayresult.
• Onlyconnecttheairconditionertothespeciedpowersupplycircuit.Powersuppliesotherthantheonespeciedmay
resultinelectricshock,overheatingandres.
•
Arrangethedrainhosetoensuresmoothdrainage.Imperfectdrainagemaycausewettingofthebuilding,furniture,etc.
•
Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small
animalswhichcanentertheunit.Onceinsidetheunit,suchanimalscancausemalfunctions,smokeorreiftheycomeintocontactwithelectricalparts.
• Do not place objects around the indoor unit.
Doingsomayhaveanadverseinuenceontheperformance,productquality,andlifeoftheairconditioner.
• This appliance is not intended to be used by persons with reduced physical, sensory or mental capabilities, or with
lackofoperationknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerningtheapplianceuseby
person responsible for their safety. Keep out of children’s reach to ensure that they do not play with the appliance.
• For care and cleaning, call service personnel.
FTP008
This is an appliance that is not accessible to the general public.
Precautions relating to area surrounding the indoor and outdoor units
îš„Be sure to follow the instructions below.
•The indoor unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound).
•Refrainfromusingtheunitsinareaspronetohighlevelsofoilysmoke,suchasakitchen.Waterleakagemayresult.
Safety Precautions