Bekijk gratis de handleiding van Daikin Altherma EHBH11CB3V (12 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 38 mensen en kreeg gemiddeld 5.0 sterren uit 19.5 reviews. Heb je een vraag over Daikin Altherma EHBH11CB3V of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/12

Operationmanual
DaikinAltherma–Lowtemperaturesplit English
Operationmanual
DaikinAltherma–Lowtemperaturesplit
EHBH04CB
EHBH08CB
EHBH11CB
EHBH16CB
EHBX04CB
EHBX08CB
EHBX11CB
EHBX16CB
EHVH04S18CB
EHVH08S18CB
EHVH08S26CB
EHVH11S18CB
EHVH11S26CB
EHVH16S18CB
EHVH16S26CB
EHVX04S18CB
EHVX08S18CB
EHVX08S26CB
EHVX11S18CB
EHVX11S26CB
EHVX16S18CB
EHVX16S26CB

Tableofcontents
Operationmanual
2
EHBH/X04~16CB+EHVH/X04~16CB
DaikinAltherma–Lowtemperaturesplit
4P3831171C–2015.01
Tableofcontents
1 Aboutthisdocument 2
2 Aboutthesystem 2
2.1 Componentsinatypicalsystemlayout ..................................... 2
3 Operation 3
3.1 Overview:Operation.................................................................. 3
3.2 Theuserinterfaceataglance ................................................... 3
3.2.1 Buttons........................................................................ 3
3.2.2 Statusicons ................................................................ 3
3.3 Spaceheating/coolingcontrol ................................................... 4
3.3.1 Settingthespaceoperationmode .............................. 4
3.3.2 Usingtheroomtemperaturehomepage .................... 4
3.3.3 Usingtheleavingwatertemperaturehomepages
(main+additional) ...................................................... 4
3.4 Domestichotwatercontrol ........................................................ 4
3.4.1 Reheatmode .............................................................. 4
3.4.2 Scheduledmode ......................................................... 5
3.4.3 Scheduled+reheatmode........................................... 5
3.4.4 UsingtheDHWtanktemperaturehomepage............ 5
3.4.5 UsingtheDHWtankboostermode ............................ 5
3.5 Advancedusage........................................................................ 5
3.5.1 Aboutchangingtheuserpermissionlevel .................. 5
3.6 Schedules:Example.................................................................. 6
3.7 Menustructure:Overviewusersettings .................................... 7
3.8 Installersettings:Tablestobefilledinbyinstaller .................... 8
3.8.1 Quickwizard ............................................................... 8
3.8.2 Spaceheating/coolingcontrol..................................... 8
3.8.3 Domestichotwatercontrol[A.4] ................................. 8
3.8.4 Contact/helpdesknumber[6.3.2]................................ 8
4 Energysavingtips 8
5 Maintenanceandservice 9
5.1 Overview:Maintenanceandservice.......................................... 9
5.2 Tofindthecontact/helpdesknumber ........................................ 9
6 Troubleshooting 9
6.1 Symptom:Youarefeelingtoocold(hot)inyourlivingroom ..... 9
6.2 Symptom:Thewateratthetapistoocold ................................ 9
6.3 Symptom:Heatpumpfailure ..................................................... 10
7 Glossary 10
1 Aboutthisdocument
Thankyouforpurchasingthisproduct.Please:
▪ Read the documentation carefully before operating the user
interfacetoensurethebestpossibleperformance.
▪ Requesttheinstallertoinformyouaboutthesettingsthatheused
to configure your system. Check if he has filled in the installer
settingstables.Ifnot,requesthimtodoso.
▪ Keepthedocumentationforfuturereference.
Targetaudience
Endusers
Documentationset
This document is part of a documentation set. The complete set
consistsof:
Document Contains… Format
General
safety
precautions
Safetyinstructionsthatyou
mustreadbeforeoperating
yoursystem
Paper(intheboxofthe
indoorunit)
Operation
manual
Quickguideforbasicusage
User
reference
guide
Detailedstepbystep
instructionsandbackground
informationforbasicand
advancedusage
Digitalfilesonhttp://
www.daikineurope.com/
supportandmanuals/
productinformation/.
Latestrevisionsofthesupplied documentationmaybeavailableon
theregionalDaikinwebsiteorviayourinstaller.
TheoriginaldocumentationiswritteninEnglish.Allotherlanguages
aretranslations.
Availablescreens
Dependingonyoursystemlayout andinstallerconfiguration,notall
screensinthisdocumentmaybeavailableonyouruserinterface.
Breadcrumbs
1
20.0°C >
18.0°C >
22.0°C >
24.0°C >
7.4.1.1 Room temperature
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
Select Scroll
Breadcrumbshelpyoutolocatewhereyouareinthemenustructure
of the user interface. This document also mentions these
breadcrumbs.
Example: Go to [7.4.1.1]: > User settings > Preset values >
Roomtemperature>Comfort(heating)
2 Aboutthesystem
Dependingonthesystemlayout,thesystemcan:
▪ Heatupaspace
▪ Cool down a space (if a heating/cooling heat pump model is
installed)
▪ Producedomestichotwater(ifaDHWtankisinstalled)
2.1 Componentsinatypicalsystem
layout
d
a b
c
e
f
gBC A
A Example:Mainzone. Livingroom.
B Example:Additionalzone. Bedroom.
C Example:Technicalroom. Garage.
aOutdoorunitheatpump
bIndoorunitheatpump
cDomestichotwater(DHW)tank
dUserinterfaceattheindoorunit
eUserinterfaceinthelivingroom,usedasroomthermostat
fUnderfloorheating
gHeatpumpconvectorsorfancoilunits

3Operation
Operationmanual
3
EHBH/X04~16CB+EHVH/X04~16CB
DaikinAltherma–Lowtemperaturesplit
4P3831171C–2015.01
INFORMATION
The indoor unit and the domestic hot water tank (if
installed)canbeseparatedorintegrateddependingonthe
indoorunittype.
3 Operation
3.1 Overview:Operation
You can operate the system via the user interface. This part
describeshowtousetheuserinterface:
Part Description
Ataglance ▪ Buttons
▪ Statusicons
Spaceheating/cooling
control
Howtocontrolspaceheating/cooling:
▪ Settingthespaceoperationmode
▪ Controllingthetemperature
Domestichotwater
control
Howtocontroldomestichotwater:
▪ Reheatmode
▪ Scheduledmode
▪ Scheduled+reheatmode
Schedules Howtoselectandprogramschedules
Menustructure Overviewofmenustructure
Installersettingstable Overviewofinstallersettings
3.2 Theuserinterfaceataglance
3.2.1 Buttons
a
ef
b
d
c
aHOMEPAGES
▪ Switchesbetweenhomepages(whenyouareonahome
page).
▪ Goestothedefaulthomepage(whenyouareinthemenu
structure).
bMALFUNCTIONINFORMATION
Ifamalfunctionoccurs, isdisplayedon thehomepages.
Press todisplaymoreinformationaboutthemalfunction.
cON/OFF
Turns ON or OFF one of the controls (room temperature,
leavingwatertemperature,DHWtanktemperature).
dMENUSTRUCTURE/BACK
▪ Opens the menu structure (when you are on a home
page).
▪ Goes up a level (when you are navigating through the
menustructure).
▪ Goesback1step(example:whenyouareprogramminga
scheduleinthemenustructure).
e NAVIGATING/CHANGINGSETTINGS
▪ Navigatesthecursoronthedisplay.
▪ Navigatesthroughthemenustructure.
▪ Changessettings.
▪ Selectsamode.
fOK
▪ Confirmsaselection.
▪ Entersasubmenuinthemenustructure.
▪ Switchesbetweendisplayingactualanddesiredvalues,or
betweendisplaying actual andoffset values (if applicable)
onthehomepages.
▪ Goes to the next step (when you are programming a
scheduleinthemenustructure).
▪ Enables youto activateordeactivate child lockif pressed
formorethan5secondsonahomepage.
▪ Enables you to activate or deactivate a function lock if
pressedformorethan5secondsinthemainmenuofthe
menustructure.
INFORMATION
Ifyoupress or whilechangingsettings,thechanges
willNOTbeapplied.
3.2.2 Statusicons
Icon Description
Spaceoperationmode=Heating.
Spaceoperationmode=Cooling.
Unitisoperating.
Desiredroomtemperature=presetvalue(Comfort;
daytime).
Desiredroomtemperature=presetvalue(Eco;
nighttime).
▪ On the room temperature home page: Desired
room temperature = according to the selected
schedule.
▪ On the DHW tank temperature home page:
DHWtankmode=Scheduledmode.
DHWtankmode=Reheatmode.
DHWtankmode=Scheduled+reheatmode.
Domestichotwateroperation.
Actualtemperature.
Desiredtemperature.
Atthenextscheduledaction,thedesiredtemperature
willincrease.
Atthenextscheduledaction,thedesiredtemperature
willNOTchange.
Atthenextscheduledaction,thedesiredtemperature
willdecrease.
Thepresetvalue(ComfortorEco)orscheduledvalue
istemporarilyoverruled.
TheDHWtankboostermodeisactiveorreadytobe
activated.
Quietmodeisactive.
Holidaymodeisactiveorreadytobeactivated.
Childlockmodeand/orfunctionlockmodeisactive.
Product specificaties
Merk: | Daikin |
Categorie: | Niet gecategoriseerd |
Model: | Altherma EHBH11CB3V |
Heb je hulp nodig?
Als je hulp nodig hebt met Daikin Altherma EHBH11CB3V stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Daikin
17 April 2025
17 April 2025
16 April 2025
16 April 2025
16 April 2025
16 April 2025
16 April 2025
16 April 2025
16 April 2025
16 April 2025
Handleiding Niet gecategoriseerd
- Proteca
- Steelton
- Saro
- Laica
- Crane
- Flaem
- Silva
- Engel
- Contax
- Jata
- Martens
- Vicks
- Keymall
- Media-tech
- Vitammy
Nieuwste handleidingen voor Niet gecategoriseerd
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025