Daikin Alira X FTXM71WVMA Handleiding
Pagina's 96 Engels Airco
Bekijk de handleiding van Daikin Alira X FTXM71WVMA gratis online of download de PDF. Deze handleiding is 96 keer bekeken. Vraag over dit model? Stel een vraag

[Sticker attachment area]
Attach the SSID&KEY sticker of wireless LAN connecting
adapter to the sticker attachment area and keep safe.
DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL
M O D E L S
FTXM20WVMA
FTXM25WVMA
FTXM35WVMA
FTXM46WVMA
FTKM20WVMA
FTKM25WVMA
FTKM35WVMA
FTKM46WVMA
Foutcodes Daikin Alira X FTXM71WVMA
Foutcodes uit de officiële handleiding, met betekenis en oplossing.
| Code | Betekenis | Oplossing | Pagina |
|---|---|---|---|
| C4 | UNIT C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR | 47 | |
| C9 | C9 FAULTY SUCTION AIR TEMPERATURE SENSOR CC FAULTY HUMIDITY SENSOR | 47 | |
| E1 | E1 CIRCUIT BOARD FAULT E5 OL STARTED | 47 | |
| E5 | E5 OL STARTED E6 FAULTY COMPRESSOR START UP | 47 | |
| E6 | E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT | 47 | |
| E7 | E7 DC FAN MOTOR FAULT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL | 47 | |
| F3 | F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL (IN COOLING) | 47 | |
| F6 | F6 HIGH PRESSURE CONTROL (IN COOLING) F8 OPERATION HALT DUE TO COMPRESSOR INTERNAL TEMPERATURE | 47 | |
| F8 | F8 OPERATION HALT DUE TO COMPRESSOR INTERNAL TEMPERATURE H0 SENSOR FAULT | 47 | |
| H0 | H0 SENSOR FAULT OUTDOOR | 47 | |
| H6 | H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR UNIT | 47 | |
| H8 | H8 DC CURRENT SENSOR FAULT H9 FAULTY SUCTION AIR TEMPERATURE SENSOR | 47 | |
| H9 | H9 FAULTY SUCTION AIR TEMPERATURE SENSOR J3 FAULTY DISCHARGE PIPE TEMPERATURE SENSOR | 47 | |
| L3 | L3 ELECTRICAL PARTS HEAT FAULT L4 HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK | 47 | |
| L4 | L4 HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK L5 OUTPUT OVERCURRENT | 47 | |
| L5 | L5 OUTPUT OVERCURRENT P4 FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR | 47 | |
| P4 | P4 FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR NOTE | 47 | |
| U0 | SYSTEM U0 REFRIGERANT SHORTAGE U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE | 47 | |
| U2 | U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE U4 FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT) | 47 | |
| U4 | U4 FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT) A1 INDOOR PCB DEFECTIVENESS | 47 |
Product specificaties
| Merk: | Daikin |
| Categorie: | Airco |
| Model: | Alira X FTXM71WVMA |
Heb je hulp nodig?
Als je hulp nodig hebt met Daikin Alira X FTXM71WVMA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden