User’s Manual
Step-Down Transformer
OL6KRT2UTF TAA HWIO
OL10KRT2UTF TAA HWIO
OL6KRT2UTF RTAA HWIO
OL10KRT2UTF RTAA HWIO
CyberPower Systems (USA), Inc.
4241 12th Avenue East Suite 400 Shakopee, MN 55379
Phone: 877-297-6937
Fax: 952-403-0009
www.CPSww.com
Copyright © 2014 CyberPower Systems, Inc.
OVERVIEW
1
The CyberPower Step-Down and Isolation Transformers support installation with hardwire ( 6KRT2UTF TAA OL10KRT2UTF TAA OL HWIO / HWIO /
OL6KRT2UTF RTAA OL10KRT2UTF RTAA), and are designed for variety of CyberPower UPS systems. When combin with the UPS, the HWIO / HWIO a ed
Step-Down configuration convert voltage from 200-240V down to 100-12s 0V. The Isolation configuration provides the UPS and connected equipment from
any outside utility line fluctuations or interference.
2U Step-Down and Isolation Transformer
User’s manual Registration card
Rackmount left rail Rackmount right rail
Tie plate (1) * 1 set
2U Rackmount ears (Stands) (2) * 1 set
Input/output terminal block cover (1)
Flat head screws M5X8L (8) * 1 set :
Pan head screws M5X12L (12) * 1 set :
Plastic washers (8) * 1 set
Screw hole dust covers (10) * 1 set
Cable for 6K UPS output 6K STF i connection (1) to nput
(Only for 6K STF)
Conduits with internal wires for 8K/10K UPS output to
10K STF input connection (1)
(Only for 10K STF)
Cable glands (2)
UNPACKING
Copyright © 2014 CyberPower Systems, Inc.
HARDWARE INSTALLATION
2
HARDWARE INSTALLATION
These versatile Step-Down Transformers can be mounted in a rackmount
or vertical tower orientation. This versatility is especially important to
growing organizations with changing needs that value having the option
to position a Step-Down Transformer on a floor or in a rackmount system.
Please follow the instructions below for the respective mounting met s.hod
SAFETY PRECAUTIONS
CAUTION! To prevent the risk of fire or electric shock, only use the
supplied hardware to attach the mounting brackets.
RACKMOUNT INSTALLATION
Step 1: Rackmount e s installation ar
Attach the two rackmount e s to the Step-Down Transformer using the ar
provided screws M5X8L*8pcs.
Step 2: Rackmount rail Installation
The rails adjust to mount in 48-cm (19-inch) panel racks from to 52
91.5cm (20.5 to inches) deep Select the proper holes in the rack for 36 .
positioning the Step-Down Transformer in the rack. The 2U Step-Down
Transformer takes up position 1 through position 6. The 3U Step-Down
Transformer takes up position 1 through position 9.
Step 3 Adjust rackmount rails to fit your rack :
Attach the rackmount rail to your rack with two M5X12L screws and two
plastic washers at the front of the rack. (Located in position 1 & position 6)
Do not tighten the screws. Adjust the rail size on the rail assembly of your
rack. Secure the rail to the rear of the rack with two M5X12L screws and
two plastic washers. Tighten all screws at the front and rear of the rail.
Place the Step-Down Transformer on a flat stable surface with the front of
the unit facing toward you. Secure the Step-Down Transformer to your
rack with four M5X12L screws at the front of the rack. The 2U Step-Down
Transformer takes up position 2 through position 5. The 3U Step-Down
Transformer takes up position 2 through position 8.
CAUTION! T Step-Down Transformer must be installed above the he
power module.


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: OL6KRT2UTFHWIORTAA
Kleur van het product: Zwart
Gewicht: 43400 g
Breedte: 433 mm
Diepte: 600 mm
Hoogte: 88.9 mm
Gewicht verpakking: 58000 g
Breedte verpakking: 600 mm
Diepte verpakking: 900 mm
Hoogte verpakking: 330 mm
Gebruikershandleiding: Ja
Materiaal behuizing: Staal
Vormfactor: Rackmontage/toren
Duurzaamheidscertificaten: RoHS
Aantal: 1
Temperatuur bij opslag: -20 - 45 °C
Luchtvochtigheid bij opslag: 0 - 95 procent
Rack-montage: Ja
Veiligheid: UL, cUL, CE
Hoogte, in bedrijf: 0 - 3000 m
Hoogte bij opslag: 0 - 15000 m
Rackcapaciteit: 2U
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 90 procent