CyberPower OL10KSTF Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor CyberPower OL10KSTF (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 58 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
For mission-critical enterprise applications
requiring maximum power protection.
GENERAL
Type Step-Down Transformer
Over Temperature
Protection Yes
INPUT
Nominal Voltage 200 V to 240 V
Frequency 50/60 Hz
Current Rating 50 A
Plug Type Hardwire (6AWGHW3FT Power
Cable Kit included)
Cord Length (ft) 3
OUTPUT
VA
10,000 (10 kVA) at 230, 240 V input
9,000 (9 kVA) at 208, 220 V input
8,000 (8 kVA) at 200 V input
Watts
10,000 (10 kW) at 230, 240 V input
9,000 (9 kW) at 208, 220 V input
8,000 (8 kW) at 200 V input
Nominal Voltage 120 V, 208 V
Frequency 50/60 Hz
Outlets - Total 7
Outlet Type (6) NEMA 5-20R, (1) Hardwire
Terminal Block
Overload Protection Circuit Breaker Protected
SPECIFICATIONS
The CyberPower Smart App Online OL10KSTF rack/tower step-down isolation
transformer converts 200 V to 240 V input voltage originating from utility
power, a UPS, or a generator to 120 V output.
The OL10KSTF has a capacity of 10,000 VA / 10,000 Watts. It features six (6)
NEMA 5-20R receptacles that can support output to NEMA 5-15P and 5-20P
plug power cords. A hardwire output terminal block provides a means to
connect to an electrical subpanel.
The included 3-foot power cable kit (6AWGHW3FT) connects the OL10KSTF
to input power. Over temperature protection safeguards your OL10KSTF from
damage if the internal heat exceeds safe operating parameters.
A Three-Year Warranty ensures that this step-down transformer has passed
our highest quality standards in design, assembly, material or workmanship.
OL10KSTF STEP-DOWN
TRANSFORMER
TYPICAL APPLICATIONS
Core Network Equipment
Hyperconverged Infrastructure (HCI)
Server Rooms
Server Virtualization Infrastructures
(VMware, Hyper-V, Citrix)
Storage Devices
VoIP Installations
FEATURES
10,000 VA/10,000 W
120 V, 208 V, 50/60 Hz Output
Over Temperature Protection
Rack/Tower Form Factor
3-Year Limited Warranty
OL10KSTF STEP-DOWN
TRANSFORMER
SPECIFICATIONS CONT.
©2018 Cyber Power Systems (USA), Inc. CyberPower is a registered trademark and brand of Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property
of their respective owners. CyberPower reserves the right to change, without notice, marketing programs, product oerings and specifications. www.cyberpowersystems.com
PHYSICAL
Form Factor Rack / Tower Convertible
Enclosure Construction Steel
Rack Mounting Hardware Included
PHYSICAL DIMENSIONS
Dimensions (WxHxD, in) 17.05 x 3.5 x 24
Dimensions (WxHxD,
mm) 433 x 88 x 600
Weight (lb) 119.7
Weight (kg) 54.4
Rack Units 2U
SHIPPING DIMENSIONS
Dimensions (WxHxD, in) 23.6 x 13 x 35.4
Dimensions (WxHxD,
mm) 600 x 330 x 900
Weight (lb) 163.7
Weight (kg) 74.4
ENVIRONMENTAL
Operating Temperature 32°F to 104°F (0°C to 40°C)
Operating Humidity 0% to 90% (non-condensing)
Operating Elevation 0 ft to 10,000 ft (0 m to 3,000 m)
Storage Temperature -4 °F to 113 °F (-20 °C to 45 °C)
Storage Relative
Humidity 0% to 95% (non-condensing)
Storage Elevation 0 ft to 50,000 ft (0 to 15,000 m)
Thermal Dissipation
(100% Load) 1914 BTU/h
Audible noise at 1M from
surface of unit 58 dBA
COMPATIBILITY
UPS Models
OL8000RT3U
OL8000RT3UPDU
OL8KRT3UHW
OL8KRTHW
OL8KRTMB
OL10000RT3U
OL10000RT3UPDU
OL10KRT3HW
OL10KRTHW
OL10KRTMB
CERTIFICATIONS
Safety UL 1778 5th Ed.
CSA C22.2 NO.107.3-05
Environmental RoHS Compliant
WARRANTY
Extended 2-Year
Warranty Optional WEXT5YR-ACC2C
Product Warranty 3 Years Limited


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: OL10KSTF
Gewicht: 54400 g
Breedte: 433 mm
Diepte: 600 mm
Hoogte: 88 mm
Gewicht verpakking: 74400 g
Breedte verpakking: 600 mm
Diepte verpakking: 900 mm
Hoogte verpakking: 330 mm
Kleur behuizing: Zwart
Duurzaamheidscertificaten: RoHS
Merkcompatibiliteit: CyberPower
Temperatuur bij opslag: -20 - 45 °C
Oververhittingsbeveiliging: Ja
Luchtvochtigheid bij opslag: 0 - 95 procent
Rack-montage: Ja
Compatibele producten: OL8000RT3U\nOL8000RT3UPDU\nOL8KRT3UHW\nOL8KRTHW\nOL8KRTMB\nOL10000RT3U\nOL10000RT3UPDU\nOL10KRT3HW\nOL10KRTHW\nOL10KRTMB
Rackcapaciteit: 2U
AC-ingangsspanning: 200 - 240 V
AC-ingangsfrequentie: 50 - 60 Hz
Bedrijfstemperatuur (T-T): 0 - 40 °C
Aantal AC uitgangen: 7 AC-uitgang(en)
Laad-capaciteit: 10 VA
AC-uitgangsvoltage: 120 - 208 V
Ingangsstroom (max): 50 A

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower OL10KSTF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd CyberPower

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd