User’s Manual
EXTENDED BATTERY MODULE (EBM)
BP36V60ART2U
BP72V60ART2U
Cyber Power Systems (USA), Inc.
4241 12th Avenue East Suite 400 Shakopee, MN 55379
Phone: -297-6937 877
Fax: 952-403-0009
http://www.cyberpowersystems.com
K01-0000 5-03 51
Copyright © Cyber Power Systems, Inc.2020
OVERVIEW
1
The CyberPower extended battery modules (BP V60ART2U V ART2U) support A polarized plugs, and are designed for variety of Cyber Power 36 / BP72 60 60
UPS systems. When combining with the UPS, the provides extended runtime with a VDC/72VDC external connection. Additional parallel-connected EBM 36
EBM provide the UPS for a longer extended runtime operation.
1K/1.5KVA or 2K/3KVA extended battery module
User’s manual Register card
Rackmount left rail Rackmount right rail
Left hanging bracket Right hanging bracket
IEC320 C14 to NEMA 5-15P power cord
Rackmount ears (Stands) (2)
Tie plate (1)
M5X7L black at head screws (8)
M5X12L black pan head screws ( ) 12
M5X6L silver pan head screws (6)
Plastic washers (8)
Screw hole dust covers ( ) 12
Rubber feet (12)
UNPACKING
Copyright © Cyber Power Systems, Inc.2020
HARDWARE INSTALLATION
2
HARDWARE INSTALLATION
These versatile can be mounted in a rackmount or vertical tower EBM
orientation. This is especially important to growing organizations with
changing needs that value having the option to position an EBM on the
floor or in a rackmount system. Please follow the instructions below for
the respective mounting methods.
SAFETY PRECAUTIONS
CAUTION! To prevent the risk of fire or electric shock, only use the
supplied hardware to attach the mounting brackets.
RACKMOUNT INSTALLATION R 4-POST RACK FO
Step 1 Remove the dust covers :
Remove the dust covers *5 pcs from the screw holes.
Step 2: Rackmount e s & hanging brackets installation ar
Attach two rackmount ears to the EBM using the provided M5X7L*8pcs
screws and tighten two hanging brackets with the M5X6L*6pcs screws.
Step 3: Rackmount rail Installation
The rails adjust to mount in 48-cm (19-inch) wide racks from 52 to
91.5cm (20.5 to 36 inches) deep. Select the proper holes in the rack for
positioning the in the rack. The takes up 2 rack units. EBM EBM
Position the guide screws on the rails into the rear rack square holes to
temporarily support the rails in place. Tighten the front rail screws on the
rack.


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: BP36V60ART2U
Kleur van het product: Zwart
Gewicht: 22900 g
Breedte: 433 mm
Diepte: 430 mm
Hoogte: 88 mm
Gewicht verpakking: 29600 g
Materiaal behuizing: Staal
Vormfactor: Rackmontage
Afmetingen verpakking (BxDxH): 550 x 590 x 240 mm
Certificering: UL1778, CSA C22.2 NO.107.3-05, FCC DOC A
Duurzaamheidscertificaten: RoHS
Uitgangsvermogen: - W
Accu/Batterij oplaadtijd: 5 uur
Temperatuur bij opslag: -15 - 45 °C
Frequentie: - Hz
Luchtvochtigheid bij opslag: 0 - 95 procent
Hoogte, in bedrijf: 0 - 3000 m
Hoogte bij opslag: 0 - 15000 m
Rackcapaciteit: 2U
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 90 procent
Batterijtechnologie: Sealed Lead Acid (VRLA)
Type batterij: 12V/9AH
Aantal batterijcellen: 6
Aantal AC uitgangen: 10 AC-uitgang(en)
Stroom (max.): 60 A
Output power capacity: - kVA
Ingang operation voltage (min): - V
Ingang operation voltage (max): - V
Uitgang operation voltage (min): 36 V
Uitgang operation voltage (max): - V
Typische backup tijd op halve lading: - min
Typische backup tijd op volledige lading: - min
Hot-swap batterij: Ja